These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

113 related articles for article (PubMed ID: 4966155)

  • 21. A novel method for quantifying the biomechanical parameters of orbital soft tissue using a corneal dynamic scheimpflug analyser: a retrospective study.
    Hwang HS; Kim EC; Kim MS; Yang SW
    BMC Ophthalmol; 2019 Feb; 19(1):53. PubMed ID: 30777066
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Goldmann applanation tonometer versus ocular response analyzer for measuring intraocular pressure after congenital cataract surgery.
    Feizi S; Faramarzi A; Kheiri B
    Eur J Ophthalmol; 2018 Sep; 28(5):582-589. PubMed ID: 30246567
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Partial contact indentation tonometry for measurement of corneal properties-independent intraocular pressure.
    Ko MW; Leung LK; Lam DC
    Mol Cell Biomech; 2012 Dec; 9(4):251-68. PubMed ID: 23724430
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Determining corneal hysteresis and preexisting intraocular pressure.
    Sergienko N; Shargorodska I
    J Cataract Refract Surg; 2009 Nov; 35(11):2033-4; author reply 2034-5. PubMed ID: 19878850
    [No Abstract]   [Full Text] [Related]  

  • 25. Comparison of Oculab Tono-Pen readings obtained from various corneal and scleral locations.
    Khan JA; Davis M; Graham CE; Trank J; Whitacre MM
    Arch Ophthalmol; 1991 Oct; 109(10):1444-6. PubMed ID: 1929938
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Effect of ocular massage on intraocular pressure and corneal biomechanics.
    Lam AK; Chen D
    Eye (Lond); 2007 Sep; 21(9):1245-6. PubMed ID: 17618239
    [No Abstract]   [Full Text] [Related]  

  • 27. Intraocular pressure: Goldmann tonometry, computational model, and calibration equation.
    Guzmán AF; Castilla AA; Guarnieri FA; Rodríguez FR
    J Glaucoma; 2013 Jan; 22(1):10-4. PubMed ID: 21946545
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Biomechanical properties of the cornea measured by the Ocular Response Analyzer and their association with intraocular pressure and the central corneal curvature.
    Franco S; Lira M
    Clin Exp Optom; 2009 Nov; 92(6):469-75. PubMed ID: 19694758
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Dynamics of corneo-scleral envelope.
    Nema HV; Phillips CI; Soden PD; Vale J
    Indian J Ophthalmol; 1978 Oct; 26(3):1-7. PubMed ID: 104926
    [No Abstract]   [Full Text] [Related]  

  • 30. What biomechanical properties of the cornea are relevant for the clinician?
    Kotecha A
    Surv Ophthalmol; 2007 Nov; 52 Suppl 2():S109-14. PubMed ID: 17998034
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Effect on intraocular pressure of extraocular muscle surgery for thyroid-associated ophthalmopathy.
    Danesh-Meyer HV; Savino PJ
    Am J Ophthalmol; 2008 May; 145(5):938-9; author reply 939. PubMed ID: 18435978
    [No Abstract]   [Full Text] [Related]  

  • 32. In-vivo corneal pulsation in relation to in-vivo intraocular pressure and corneal biomechanics assessed in-vitro. An animal pilot study.
    Rogala MM; Danielewska ME; Antończyk A; Kiełbowicz Z; Rogowska ME; Kozuń M; Detyna J; Iskander DR
    Exp Eye Res; 2017 Sep; 162():27-36. PubMed ID: 28689748
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Application of structural analysis to the mechanical behaviour of the cornea.
    Anderson K; El-Sheikh A; Newson T
    J R Soc Interface; 2004 Nov; 1(1):3-15. PubMed ID: 16849148
    [TBL] [Abstract][Full Text] [Related]  

  • 34. In vitro studies of trans- and intraepithelial potentials of the cornea.
    Ehlers N
    Exp Eye Res; 1973 May; 15(5):553-65. PubMed ID: 4197260
    [No Abstract]   [Full Text] [Related]  

  • 35. [Biomechanical analysis and explication of corneal curve changes after oculomotor muscle surgery].
    Jo A; Trajer D; Hudec M; Nikolić V
    Verh Anat Ges; 1976; (70 Pt 1):509-12. PubMed ID: 1023606
    [No Abstract]   [Full Text] [Related]  

  • 36. Numerical modelling of corneal biomechanical behaviour.
    Elsheikh A; Wang D
    Comput Methods Biomech Biomed Engin; 2007 Apr; 10(2):85-95. PubMed ID: 18651274
    [TBL] [Abstract][Full Text] [Related]  

  • 37. [Effect of brimonidine on central corneal thickness].
    Grüb M; Mielke J; Schlote T; Rohrbach M
    Klin Monbl Augenheilkd; 2012 Mar; 229(3):236-40. PubMed ID: 22161473
    [TBL] [Abstract][Full Text] [Related]  

  • 38. The nucleus for accommodation in the midbrain of the macaque.
    Jampel RS; Mindel J
    Invest Ophthalmol; 1967 Feb; 6(1):40-50. PubMed ID: 4959576
    [No Abstract]   [Full Text] [Related]  

  • 39. Reproducibility of viscoelastic property and intraocular pressure measurements obtained with the Ocular Response Analyzer.
    Kopito R; Gaujoux T; Montard R; Touzeau O; Allouch C; Borderie V; Laroche L
    Acta Ophthalmol; 2011 May; 89(3):e225-30. PubMed ID: 20738262
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Physiology of the cornea.
    Mishima S; Hedbys BO
    Int Ophthalmol Clin; 1968; 8(3):527-60. PubMed ID: 4243831
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.