These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

175 related articles for article (PubMed ID: 496626)

  • 1. Carotid endarterectomy in the presence of contralateral carotid occlusion: the role of EEG and intraluminal shunting.
    Phillips MR; Johnson WC; Scott RM; Vollman RW; Levine H; Nabseth DC
    Arch Surg; 1979 Nov; 114(11):1232-9. PubMed ID: 496626
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The value of intraoperative EEG monitoring during carotid endarterectomy.
    Cho I; Smullens SN; Streletz LJ; Fariello RG
    Ann Neurol; 1986 Oct; 20(4):508-12. PubMed ID: 3789666
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The risk-benefit ratio of intraoperative shunting during carotid endarterectomy. Relevancy to operative and postoperative results and complications.
    Sundt TM; Ebersold MJ; Sharbrough FW; Piepgras DG; Marsh WR; Messick JM
    Ann Surg; 1986 Feb; 203(2):196-204. PubMed ID: 3947156
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The selection for shunting in patients with severe bilateral carotid lesions.
    Sbarigia E; Speziale F; Colonna M; Taurino M; Rizzo L; Massucci M; Massimi GJ; Fiorani P
    Eur J Vasc Surg; 1993 Mar; 7 Suppl A():3-7. PubMed ID: 8458443
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Routine electroencephalographic (EEG) monitoring during carotid endarterectomy.
    Whittemore AD; Kauffman JL; Kohler TR; Mannick JA
    Ann Surg; 1983 Jun; 197(6):707-13. PubMed ID: 6859980
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Routine shunting is a safe and reliable method of cerebral protection during carotid endarterectomy.
    Bellosta R; Luzzani L; Carugati C; Talarico M; Sarcina A
    Ann Vasc Surg; 2006 Jul; 20(4):482-7. PubMed ID: 16639651
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Carotid endarterectomy with routine electroencephalography and selective shunting: Influence of contralateral internal carotid artery occlusion and utility in prevention of perioperative strokes.
    Schneider JR; Droste JS; Schindler N; Golan JF; Bernstein LP; Rosenberg RS
    J Vasc Surg; 2002 Jun; 35(6):1114-22. PubMed ID: 12042721
    [TBL] [Abstract][Full Text] [Related]  

  • 8. EEG monitoring during carotid endarterectomy.
    Fletcher JP; Morris JG; Little JM; Kershaw LZ
    Aust N Z J Surg; 1988 Apr; 58(4):285-8. PubMed ID: 3254133
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Cerebral protection during carotid endarterectomy--EEG monitoring as a guide to the use of intraluminal shunts.
    Wassmann H; Fischdick G; Jain KK
    Acta Neurochir (Wien); 1984; 71(1-2):99-108. PubMed ID: 6731060
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Therapy of carotid stenosis in contralateral occlusion of the internal carotid artery].
    Wandschneider W; Weihsbeck E; Wurnig P; Mendel HJ; Denck H
    Vasa; 1990; 19(2):134-7. PubMed ID: 2371787
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Incompleteness of the circle of Willis is related to EEG-based shunting during carotid endarterectomy.
    Pennekamp CW; van Laar PJ; Hendrikse J; den Ruijter HM; Bots ML; van der Worp HB; Kappelle LJ; Buhre WF; Bleys RL; Moll FL; de Borst GJ
    Eur J Vasc Endovasc Surg; 2013 Dec; 46(6):631-7. PubMed ID: 24091095
    [TBL] [Abstract][Full Text] [Related]  

  • 12. EEG as a criterion for shunt need in carotid endarterectomy.
    Pinkerton JA
    Ann Vasc Surg; 2002 Nov; 16(6):756-61. PubMed ID: 12415483
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Continuous electroencephalographic monitoring and selective shunting reduces neurologic morbidity rates in carotid endarterectomy.
    Plestis KA; Loubser P; Mizrahi EM; Kantis G; Jiang ZD; Howell JF
    J Vasc Surg; 1997 Apr; 25(4):620-8. PubMed ID: 9129616
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Selective shunting during carotid endarterectomy based on two-channel computerized electroencephalographic/compressed spectral array analysis.
    Tempelhoff R; Modica PA; Grubb RL; Rich KM; Holtmann B
    Neurosurgery; 1989 Mar; 24(3):339-44. PubMed ID: 2927606
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Intraoperative electroencephalographic monitoring during carotid surgery with routine shunting.
    Scheyvaerts M; Limet R
    Ann Vasc Surg; 1990 Jul; 4(4):318-22. PubMed ID: 2364045
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Anesthetic experience for carotid endarterectomy in a patient with dilated cardiomyopathy under jugular venous oxygen saturation monitoring].
    Toyota K; Sato N; Ozasa H; Uchida H
    Masui; 2002 Sep; 51(9):1010-2. PubMed ID: 12382393
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Limitations of electroencephalographic monitoring in the detection of cerebral ischemia accompanying carotid endarterectomy.
    Kresowik TF; Worsey MJ; Khoury MD; Krain LS; Shamma AR; Sharp WJ; Stern JA; Corson JD
    J Vasc Surg; 1991 Mar; 13(3):439-43. PubMed ID: 1999866
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Does contralateral carotid occlusion influence neurologic fate of carotid endarterectomy?
    Sachs SM; Fulenwider JT; Smith RB; Darden WA; Salam AA; Perdue GD
    Surgery; 1984 Nov; 96(5):839-44. PubMed ID: 6495174
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A retrospective comparison of the use of shunts during carotid endarterectomy.
    Hertzer NR; Beven EG
    Surg Gynecol Obstet; 1980 Jul; 151(1):81-4. PubMed ID: 6770477
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Clinical experience with carotid stump pressure and EEG monitoring to determine shunt placement during carotid endarterectomy.
    Sweezer WP; Hayes DF; Organ CH
    J Natl Med Assoc; 1983 Jun; 75(6):583-7. PubMed ID: 6876190
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.