These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

121 related articles for article (PubMed ID: 4974720)

  • 1. Effect of anatomical irregularities on the dose in electron beam therapy.
    Karjalainen P; Brenner M; Rytilä A
    Acta Radiol Ther Phys Biol; 1968 Apr; 7(2):129-40. PubMed ID: 4974720
    [No Abstract]   [Full Text] [Related]  

  • 2. Back-scattering from metals in superficial therapy with high energy electrons.
    Saunders JE; Peters VG
    Br J Radiol; 1974 Aug; 47(560):467-70. PubMed ID: 4213594
    [No Abstract]   [Full Text] [Related]  

  • 3. [Influence of natural bones on the dose distribution of electrons and photons up to 42 MeV].
    Fehrentz D; Schröder-Babo P; Canzler R; Poser H
    Strahlentherapie; 1973 Dec; 146(6):644-56. PubMed ID: 4210110
    [No Abstract]   [Full Text] [Related]  

  • 4. High-energy electron dose perturbations in regions of tissue heterogeneity.
    Boone ML; Almond PR; Wright AE
    Ann N Y Acad Sci; 1969 Jul; 161(1):214-32. PubMed ID: 4979826
    [No Abstract]   [Full Text] [Related]  

  • 5. HIGH-ENERGY MOVING FIELD ELECTRON BEAM FOR CANCER THERAPY.
    LANZL LH
    Acta Unio Int Contra Cancrum; 1964; 20():1707-14. PubMed ID: 14244590
    [No Abstract]   [Full Text] [Related]  

  • 6. Dose enhancement in bone in electron beam therapy.
    Prasad SC; Ames TE; Howard TB; Bassano DA; Chung CT; King GA; Sagerman RH
    Radiology; 1984 May; 151(2):513-6. PubMed ID: 6424176
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Influence of bone tissue upon dose distribution in high energy electron beam therapy.
    Hattori H; Kitabatake T
    Tohoku J Exp Med; 1968 Aug; 95(4):351-8. PubMed ID: 4974292
    [No Abstract]   [Full Text] [Related]  

  • 8. Lead shielding thickness for dose reduction of 7- to 28MeV electrons.
    Giarratano JC; Duerkes RJ; Almond PR
    Med Phys; 1975; 2(6):336-7. PubMed ID: 811969
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Lead shielding thickness for dose reduction of 5 MeV electrons.
    Prasad SG; Parthasaradhi K; Lee Y; Garces R
    Med Phys; 1989; 16(5):807-8. PubMed ID: 2509872
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Inhomogeneity of electron beam dose distribution].
    Chierego G
    Radiol Med; 1990 Oct; 80(4 Suppl 1):43-5. PubMed ID: 2251417
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Calculation of the dose in the build-up region for high energy photon beam. Treatment planning when beam spoilers are employed.
    McKenna MG; Chen XG; Altschuler MD; Bloch P
    Radiother Oncol; 1995 Jan; 34(1):63-8. PubMed ID: 7792400
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Field shaping in electron beam therapy.
    Khan FM; Moore VC; Levitt SH
    Br J Radiol; 1976 Oct; 49(586):883-6. PubMed ID: 824008
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Optimization of 3D conformal electron beam therapy in inhomogeneous media by concomitant fluence and energy modulation.
    Asell M; Hyödynmaa S; Gustafsson A; Brahme A
    Phys Med Biol; 1997 Nov; 42(11):2083-100. PubMed ID: 9394399
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The effect of inhomogeneities on dose distributions of high-energy electrons.
    Brenner M; Karjalainen P; Rytilä A; Jungar H
    Ann N Y Acad Sci; 1969 Jul; 161(1):233-42. PubMed ID: 4979827
    [No Abstract]   [Full Text] [Related]  

  • 15. [Dose distributions of fast electrons with an energy of 7-24 Mev in electromagnetic beam formation].
    Shambulov RS; Khvan GV; Saĭbekov TS; Azhigaliev NA; Shuinbekov AD
    Med Radiol (Mosk); 1983 Mar; 28(3):14-8. PubMed ID: 6403798
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Measurements of electron-beam energy with rapid-processed film.
    Feldman A; de Almeida CE; Almond PR
    Med Phys; 1974; 1(2):74-6. PubMed ID: 4215948
    [No Abstract]   [Full Text] [Related]  

  • 17. Electron beam central axis depth dose measurements.
    Kirby TH; Gastorf RJ; Hanson WF; Berkley LW; Gagnon WF; Hazle JD; Shalek RJ
    Med Phys; 1985; 12(3):357-61. PubMed ID: 3925311
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Investigation of buildup dose from electron contamination of clinical photon beams.
    Petti PL; Goodman MS; Gabriel TA; Mohan R
    Med Phys; 1983; 10(1):18-24. PubMed ID: 6405143
    [TBL] [Abstract][Full Text] [Related]  

  • 19. BIOPHYSICAL ASPECTS OF THE USE OF HIGH ENERGY ELECTRONS.
    LAUGHLIN JS
    Acta Unio Int Contra Cancrum; 1964; 20():1704-6. PubMed ID: 14244589
    [No Abstract]   [Full Text] [Related]  

  • 20. Electron contamination from photon beam collimators.
    Nilsson B; Brahme A
    Radiother Oncol; 1986 Mar; 5(3):235-44. PubMed ID: 3085172
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.