These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

141 related articles for article (PubMed ID: 498262)

  • 1. Foreign body retrieval from the heart by two catheter technique.
    Khaja F; Lakier J
    Cathet Cardiovasc Diagn; 1979; 5(3):263-8. PubMed ID: 498262
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The use of pigtail catheters for retrieval of foreign bodies from the cardiovascular system.
    Auge JM; Oriol A; Serra C; Crexells C
    Cathet Cardiovasc Diagn; 1984; 10(6):625-8. PubMed ID: 6391687
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Transvenous retrieval of central embolized fragments of venous catheters (author's transl)].
    Müller US; Gräwe G; Bender F
    Z Kardiol; 1979 Mar; 68(3):180-2. PubMed ID: 442761
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Snare retrieval of a catheter fragment with inaccessible ends from the pulmonary artery.
    Greenfield DH; McMullan GK; Parisi AF; Askenazi J
    Cathet Cardiovasc Diagn; 1978; 4(1):87-90. PubMed ID: 647778
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Nonsurgical removal of intravascular foreign bodies.
    Zollikofer C; Nath PH; Castaneda-Zuniga WR; Probst P; Barreto A; Tadavarthy SM; Amplatz K
    Rofo; 1979 May; 130(5):590-3. PubMed ID: 155629
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Transfemoral snaring of broken catheters from the right heart in small infants.
    Chung KJ; Chernoff HL; Leape LL; Kreidberg MB
    Cathet Cardiovasc Diagn; 1980; 6(3):331-5. PubMed ID: 6778616
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Retrieval of lost catheters by a myocardial biopsy catheter device.
    Bashour TT; Banks T; Cheng TO
    Chest; 1974 Oct; 66(4):395-6. PubMed ID: 4415618
    [No Abstract]   [Full Text] [Related]  

  • 8. Nonsurgical retrieval of an accidentally dislodged vent catheter retention ring.
    Kuribayashi S; Ootaki M; Watabe T; Matsuyama S; Kawada S; Koide S
    Cardiovasc Intervent Radiol; 1985; 8(2):109-11. PubMed ID: 3910244
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Retrieval of embolized central venous catheters by a Dormia ureteral stone dislodger with straight filiform tip.
    Drabinsky M
    Chest; 1976 Mar; 69(3):435-7. PubMed ID: 971620
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Intravascular foreign bodies: loop-snare retrieval system with a three-lumen catheter.
    Furui S; Yamauchi T; Makita K; Takeshita K; Irie T; Tsuchiya K; Sawada S; Nakamura H; Okazaki M
    Radiology; 1992 Jan; 182(1):283-4. PubMed ID: 1727299
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Percutaneous retrieval of broken silastic catheter from the left atrium in a critically Ill premature infant.
    Massin M; Lombet J; Rigo J
    Cathet Cardiovasc Diagn; 1997 Dec; 42(4):409-11. PubMed ID: 9408624
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The nonsurgical retrieval of intracardiac foreign bodies--an international survey.
    Bloomfield DA
    Cathet Cardiovasc Diagn; 1978; 4(1):1-14. PubMed ID: 647770
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Nonsurgical technique for removal of catheter fragments in the heart and the great vessels].
    Tanaka M; Iyomasa Y; Abe T; Murase M; Kawamura M; Nogaki H; Takeuchi E; Kakihara R; Hibi M; Suenaga Y
    Nihon Geka Gakkai Zasshi; 1983 Aug; 84(8):674-8. PubMed ID: 6676637
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Retrieval of endobronchial foreign bodies in children: involving the cardiac catheterization lab.
    Thatte NM; Guglani L; Turner DR; Forbes TJ; Gowda ST
    Pediatrics; 2014 Sep; 134(3):e865-9. PubMed ID: 25157007
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Angiographic retrieval of foreign bodies in pulmonary artery: a report of three cases.
    Ando K; Sano A; Kigami Y; Kanaoka N; Matsumoto S; Ishikura S; Okada T; Yamada K; Mayumi K; Nakatsu M
    Radiat Med; 1993; 11(2):69-74. PubMed ID: 8316647
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Nonsurgical removal of a catheter embolus from the heart of a foal.
    Hoskinson JJ; Wooten P; Evans R
    J Am Vet Med Assoc; 1991 Jul; 199(2):233-5. PubMed ID: 1890034
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Use of a coronary guiding catheter to direct a snare in removal of a retained catheter fragment.
    Mehan VK; Lokhandwala YY; Kale PA
    Cathet Cardiovasc Diagn; 1990 Dec; 21(4):294-5. PubMed ID: 2276207
    [No Abstract]   [Full Text] [Related]  

  • 18. Catheter-aided extraction of a steel coil accidentally lodged in the right ventricle.
    Radojković S; Kamenica S; Jasović M; Draganić M
    Cardiovasc Intervent Radiol; 1980; 3(3):153-5. PubMed ID: 7407809
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Extraction of foreign bodies (catheters) from the right atrium and the abdominal aorta by the percutaneous route. Report of 2 cases and review of the literature].
    Espinosa Mejía R; Carrasco Guerra H; Barboza JS; Fuenmayor Arocha A; Phillips V
    Arch Inst Cardiol Mex; 1983; 53(2):143-6. PubMed ID: 6349564
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Percutaneous retrieval of a broken catheter from the left atrium in an adult.
    Ramondo AB; Favero L; Chioin R
    J Interv Cardiol; 2002 Oct; 15(5):417-9. PubMed ID: 12440189
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.