These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 4998805)

  • 1. Tissue toxicity from rubber endotracheal tubes.
    Guess WL; Stetson JB
    Int Anesthesiol Clin; 1970; 8(4):823-8. PubMed ID: 4998805
    [No Abstract]   [Full Text] [Related]  

  • 2. Rubber for tracheal tubes.
    Guess WL
    Int Anesthesiol Clin; 1970; 8(4):815-21. PubMed ID: 4998804
    [No Abstract]   [Full Text] [Related]  

  • 3. [Experimental study on compatibility of endotracheal prostheses (author's transl)].
    Weerda H
    Laryngol Rhinol Otol (Stuttg); 1975 Aug; 54(8):663-7. PubMed ID: 129638
    [TBL] [Abstract][Full Text] [Related]  

  • 4. An engineering analysis of intratracheal tube cuffs.
    McGinnis GE; Shively JG; Patterson RL; Magovern GJ
    Anesth Analg; 1971; 50(4):557-64. PubMed ID: 5105109
    [No Abstract]   [Full Text] [Related]  

  • 5. Obstructive fibrinous tracheal pseudomembrane. A potentially fatal complication of tracheal intubation.
    Deslée G; Brichet A; Lebuffe G; Copin MC; Ramon P; Marquette CH
    Am J Respir Crit Care Med; 2000 Sep; 162(3 Pt 1):1169-71. PubMed ID: 10988148
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of cuffed endotracheal tubes on tracheal mucous velocity.
    Sackner MA; Hirsch J; Epstein S
    Chest; 1975 Dec; 68(6):774-7. PubMed ID: 1192854
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A comparison of CO2 laser ignition of the Xomed, plastic, and rubber endotracheal tubes.
    Sosis MB; Dillon FX
    Anesth Analg; 1993 Feb; 76(2):391-3. PubMed ID: 8424521
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Tracheal injury using a gum elastic bougie within a RAE endotracheal tube.
    Prasad MM; Lim KS; Kumar CM
    Anaesth Intensive Care; 2016 May; 44(3):428. PubMed ID: 27246946
    [No Abstract]   [Full Text] [Related]  

  • 9. [Contact allergy-induced tracheal stenosis caused by vulcanization accelerators in the endotracheal tube?].
    Niehaus HH; Enzmann H
    HNO; 1995 Jul; 43(7):446-9. PubMed ID: 7673004
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A countermeasure for the vocal and tracheal disturbances caused by the long-term use of the endotracheal tube in about 56 cases.
    Kawai H; Haraguchi Y; Ishihara J; Kajiwara S; Taguchi H; Saitoh K; Wakabayashi J
    Panminerva Med; 1986; 28(4):413-6. PubMed ID: 3574973
    [No Abstract]   [Full Text] [Related]  

  • 11. Tissue testing of polymers.
    Guess WL
    Int Anesthesiol Clin; 1970; 8(4):787-804. PubMed ID: 4998802
    [No Abstract]   [Full Text] [Related]  

  • 12. Causes of damage to tissues by polymers and elastomers used in the fabrication of tracheal devices.
    Stetson JB; Guess WL
    Anesthesiology; 1970 Dec; 33(6):635-52. PubMed ID: 4921407
    [No Abstract]   [Full Text] [Related]  

  • 13. [A new method of cuff inflation for the prevention of tracheal complications during long term artificial respiration].
    Wolff G; Hasse J; Grädel E; Baer E; Kellerhals B
    Helv Chir Acta; 1974 Mar; 41(1-2):201-6. PubMed ID: 4215780
    [No Abstract]   [Full Text] [Related]  

  • 14. Prolonged endotracheal intubation.
    atcher CR
    Ann Thorac Surg; 1968 May; 5(5):478-80. PubMed ID: 5647937
    [No Abstract]   [Full Text] [Related]  

  • 15. [Damage in the respiratory tract following long-term intubation and tracheotomy in adults with special consideration to morphological changes].
    Hegendörfer U; Peter K; Rückert U
    Anaesthesist; 1970 Dec; 19(12):460-8. PubMed ID: 5496210
    [No Abstract]   [Full Text] [Related]  

  • 16. Tracheal collapse in tracheostomized infants: resistance in reference to flow rates in a variety of tracheostomy tubes.
    Murphy DA; Popkin J
    J Pediatr Surg; 1971 Jun; 6(3):314-23. PubMed ID: 5088940
    [No Abstract]   [Full Text] [Related]  

  • 17. [Apropos of various complications of prolonged intubation].
    Otteni JC; Rapp C; Gauthier-Lafaye P
    Anesth Analg (Paris); 1968; 25(4):367-71. PubMed ID: 5717059
    [No Abstract]   [Full Text] [Related]  

  • 18. Persistent tracheal dilatation: onset after brief mechanical ventilation with a "soft-cuff" endotracheal tube.
    Honig EG; Francis PB
    South Med J; 1979 Apr; 72(4):487-90. PubMed ID: 432692
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Extensive tracheal necrosis associated with a prestretched tracheostomy tube cuff.
    Martinez LR; Kalter RD
    Anesthesiology; 1971 May; 34(5):488-9. PubMed ID: 4928978
    [No Abstract]   [Full Text] [Related]  

  • 20. Tracheal tubes in neuroanaesthesia. Nylon reinforced latex rubber tracheal tubes.
    Wright PJ; Mundy JV
    Anaesthesia; 1987 Sep; 42(9):1012-4. PubMed ID: 3674343
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.