These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

115 related articles for article (PubMed ID: 5024776)

  • 1. The Monsanto polyacrylonitrile hollow-fiber artificial kidney.
    Salyer IO; Ball GL; Beemsterboer ; Leonard RL; Merrill JT; Hampers CL; Lowrie EG
    J Biomed Mater Res; 1972 Mar; 6(2):59-79. PubMed ID: 5024776
    [No Abstract]   [Full Text] [Related]  

  • 2. [A new method of hemodialysis combining a high permeability membrane for the medium molecules and a dialysis bath in a closed circuit].
    Funck-Brentano JL; Sausse A; Man NK; Granger A; Rondon-Nucete M; Zingraff J; Jungers P
    Proc Eur Dial Transplant Assoc; 1972; 9():55-66. PubMed ID: 4668928
    [No Abstract]   [Full Text] [Related]  

  • 3. [Hemodialyses with polyacrylonitrile membranes and their reutilization (author's transl)].
    Krpan A; Varlaj V; Ivancević D; Molnar V
    Lijec Vjesn; 1978 Mar; 100(3):183-6. PubMed ID: 661494
    [No Abstract]   [Full Text] [Related]  

  • 4. Laboratory and clinical evaluation of a small countercurrent dialyzer, the Miniklung.
    Hunt JR; Sadler JH; Shinaberger JH; Galletti PM
    Trans Am Soc Artif Intern Organs; 1968; 14():109-13. PubMed ID: 5701521
    [No Abstract]   [Full Text] [Related]  

  • 5. Design of functional hollow fiber membranes modified with phospholipid polymers for application in total hemopurification system.
    Ye SH; Watanabe J; Takai M; Iwasaki Y; Ishihara K
    Biomaterials; 2005 Aug; 26(24):5032-41. PubMed ID: 15769539
    [TBL] [Abstract][Full Text] [Related]  

  • 6. In vitro performance of the disposable Kiil envelope.
    Lips P; Kon T; Weber D; Mrava GL; Nosé Y
    J Biomed Mater Res; 1970 Dec; 4(4):469-85. PubMed ID: 5487552
    [No Abstract]   [Full Text] [Related]  

  • 7. [First experiences with the cuprophane coil ExO1].
    Schmidt P; Mayrhofer E; Kotzaurek R
    Wien Med Wochenschr; 1969 May; 119(22):409-11. PubMed ID: 5801628
    [No Abstract]   [Full Text] [Related]  

  • 8. ASAHI hollow fiber kidney (ASAHI HFK) --- progress report.
    Maeda K; Ota K; Saito A; Shimoji T; Amano I
    Trans Am Soc Artif Intern Organs; 1974; 20A():344-52. PubMed ID: 4450356
    [No Abstract]   [Full Text] [Related]  

  • 9. Chronic hemodialysis with the hollow fiber artificial kidney (HFAK).
    Gotch F; Lipps B; Weaver J; Brandes J; Rosin J; Sargent J; Oja P
    Trans Am Soc Artif Intern Organs; 1969; 15():87-96. PubMed ID: 5791436
    [No Abstract]   [Full Text] [Related]  

  • 10. Perm-selective dialysis membranes. I. Films based on dimethylaminoethyl methacrylate copolymers.
    Muir WM; Courtney JM; Gray RA; Ritchie PD
    J Biomed Mater Res; 1971 Sep; 5(5):415-45. PubMed ID: 5120384
    [No Abstract]   [Full Text] [Related]  

  • 11. Uremic blood cleansing by diafiltration using a hollow fiber ultrafilter.
    Henderson LW; Ford C; Colton CK; Bluemle LW; Bixler HJ
    Trans Am Soc Artif Intern Organs; 1970; 16():107-12. PubMed ID: 5460441
    [No Abstract]   [Full Text] [Related]  

  • 12. Development of continuous implantable renal replacement: past and future.
    Fissell WH; Fleischman AJ; Humes HD; Roy S
    Transl Res; 2007 Dec; 150(6):327-36. PubMed ID: 18022594
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Microcapsule artificial kidney and medium molecular weight clearance.
    Chang TM
    Proc Eur Dial Transplant Assoc; 1972; 9():568-74. PubMed ID: 4668931
    [No Abstract]   [Full Text] [Related]  

  • 14. All high-flux membranes are equal but some high-flux membranes are less equal than others.
    Vanholder R; Pedrini LA
    Nephrol Dial Transplant; 2008 May; 23(5):1481-3. PubMed ID: 18305315
    [No Abstract]   [Full Text] [Related]  

  • 15. A new cuprophan no-prime disposable cartridge dialyzer.
    Miller FW; Clark JE; Jones CP; Smeltzer KL; Bluemle LW
    Trans Am Soc Artif Intern Organs; 1968; 14():126-31. PubMed ID: 5701523
    [No Abstract]   [Full Text] [Related]  

  • 16. Twin Coil: performance and predictability.
    Lowrie EG; Hampers CL; Merrill JP
    Trans Am Soc Artif Intern Organs; 1969; 15():60-4. PubMed ID: 5791431
    [No Abstract]   [Full Text] [Related]  

  • 17. Parameters affecting preparation of nylon-based hemodialysis membranes.
    Luttinger M; Cooper CW
    J Biomed Mater Res; 1970 Sep; 4(3):281-93. PubMed ID: 5469179
    [No Abstract]   [Full Text] [Related]  

  • 18. Middle molecule clearance in current dialysers.
    von Hartitzsch B; Hoenich NA; Peterson RJ; Buselmeier TJ; Kerr DN; Kjellstrand CM
    Proc Eur Dial Transplant Assoc; 1973; 10(0):522-7. PubMed ID: 4802533
    [No Abstract]   [Full Text] [Related]  

  • 19. [The development of artificial kidney--from sausage casing to capillary fibers].
    Hofmann B
    Tidsskr Nor Laegeforen; 1999 Mar; 119(8):1100-3. PubMed ID: 10228412
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Perm-selective dialysis membranes. II. Films based on acrylic acid-n-butyl methacrylate copolymers--a critical comparison with cellulose films.
    Muir WM; Gray RA; Courtney JM; Ritchie PD
    J Biomed Mater Res; 1973 Jan; 7(1):3-37. PubMed ID: 4691157
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 6.