These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
147 related articles for article (PubMed ID: 5045264)
1. Investigation of three-surface properties of several metals and their relation to blood compatibility. DePalma VA; Baier RE; Ford JW; Glott VL; Furuse A J Biomed Mater Res; 1972; 6(4):37-75. PubMed ID: 5045264 [No Abstract] [Full Text] [Related]
2. Surface mechanical properties, corrosion resistance, and cytocompatibility of nitrogen plasma-implanted nickel-titanium alloys: a comparative study with commonly used medical grade materials. Yeung KW; Poon RW; Chu PK; Chung CY; Liu XY; Lu WW; Chan D; Chan SC; Luk KD; Cheung KM J Biomed Mater Res A; 2007 Aug; 82(2):403-14. PubMed ID: 17295246 [TBL] [Abstract][Full Text] [Related]
3. [Study of a new medical stainless steel]. Ren Y; Yang K; Zhang B; Yang H Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2006 Oct; 23(5):1101-3, 1122. PubMed ID: 17121363 [TBL] [Abstract][Full Text] [Related]
6. [The relationship of metal intravascular stand's surface composition and design to haemocompatibility]. Xiao M; Ling Y Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2005 Feb; 22(1):217-20. PubMed ID: 15762154 [TBL] [Abstract][Full Text] [Related]
7. Impact on the thrombogenicity of surface oxide properties of 316l stainless steel for biomedical applications. Shih CC; Shih CM; Su YY; Lin SJ J Biomed Mater Res A; 2003 Dec; 67(4):1320-8. PubMed ID: 14624519 [TBL] [Abstract][Full Text] [Related]
8. Is galvanic corrosion between titanium alloy and stainless steel spinal implants a clinical concern? Serhan H; Slivka M; Albert T; Kwak SD Spine J; 2004; 4(4):379-87. PubMed ID: 15246296 [TBL] [Abstract][Full Text] [Related]
9. [Corrosion and haemocompatibility of 316L stainless steel with electroplated Rh film]. Liu J; Yang D; Liang C; Guo L; Kong L; Cai Y Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2001 Jun; 18(2):169-72. PubMed ID: 11450526 [TBL] [Abstract][Full Text] [Related]
10. Chemical, corrosion and topographical analysis of stainless steel implants after different implantation periods. Chrzanowski W; Armitage DA; Knowles JC; Szade J; Korlacki W; Marciniak J J Biomater Appl; 2008 Jul; 23(1):51-71. PubMed ID: 18467745 [TBL] [Abstract][Full Text] [Related]
11. [Biodeterioration and corrosion of metallic implants and prostheses]. López GD Medicina (B Aires); 1993; 53(3):260-74. PubMed ID: 8114635 [TBL] [Abstract][Full Text] [Related]
12. Anodized titanium and stainless steel in contact with CFRP: an electrochemical approach considering galvanic corrosion. Mueller Y; Tognini R; Mayer J; Virtanen S J Biomed Mater Res A; 2007 Sep; 82(4):936-46. PubMed ID: 17335021 [TBL] [Abstract][Full Text] [Related]
13. Activation of human leukocytes on tantalum trabecular metal in comparison to commonly used orthopedic metal implant materials. Schildhauer TA; Peter E; Muhr G; Köller M J Biomed Mater Res A; 2009 Feb; 88(2):332-41. PubMed ID: 18286637 [TBL] [Abstract][Full Text] [Related]
14. The current status of in vivo screening of synthetic implant materials for blood compatibility. Gott VL; Furuse A Med Instrum; 1973; 7(2):121-4. PubMed ID: 4718485 [No Abstract] [Full Text] [Related]
15. In vitro surface corrosion of stainless steel and NiTi orthodontic appliances. Shin JS; Oh KT; Hwang CJ Aust Orthod J; 2003 Apr; 19(1):13-8. PubMed ID: 12790351 [TBL] [Abstract][Full Text] [Related]
16. Material-specific thrombin generation following contact between metal surfaces and whole blood. Hong J; Azens A; Ekdahl KN; Granqvist CG; Nilsson B Biomaterials; 2005 Apr; 26(12):1397-403. PubMed ID: 15482827 [TBL] [Abstract][Full Text] [Related]
17. Corrosion resistance of stressed NiTi and stainless steel orthodontic wires in acid artificial saliva. Huang HH J Biomed Mater Res A; 2003 Sep; 66(4):829-39. PubMed ID: 12926035 [TBL] [Abstract][Full Text] [Related]
18. Some methods for in vitro estimation of the blood compatibility of biomaterials. Mason RG Bull N Y Acad Med; 1972 Feb; 48(2):407-24. PubMed ID: 4500651 [No Abstract] [Full Text] [Related]
19. [Interrelationship between contact coagulation, surface charge and roughness]. Chepurov AK; Mertsalova NN Fiziol Zh SSSR Im I M Sechenova; 1978 Nov; 64(11):1559-67. PubMed ID: 153245 [TBL] [Abstract][Full Text] [Related]
20. [Effect of surface roughness of polymers on thrombus formation]. Chepurov AK; Mertsalova NN; Dubovich TI; Ifashkin GV; Chekanova VD Med Tekh; 1977; (6):25-9. PubMed ID: 145536 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]