These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

138 related articles for article (PubMed ID: 5055326)

  • 1. Limitations of 133 Xe washout technique in estimation of renal blood flow.
    Mowat P; Lupu AN; Maxwell MH
    Am J Physiol; 1972 Sep; 223(3):682-8. PubMed ID: 5055326
    [No Abstract]   [Full Text] [Related]  

  • 2. To the editor: limitations of 133 Xe washout technique in estimation of renal blood flow.
    Gutman RA
    Am J Physiol; 1973 Mar; 224(3):723. PubMed ID: 4691291
    [No Abstract]   [Full Text] [Related]  

  • 3. A weighted least-squares technique for the analysis of kinetic data and its application to the study of renal xenon washout in dogs and man.
    Dell RB; Sciacca R; Lieberman K; Case DB; Cannon PJ
    Circ Res; 1973 Jan; 32(1):71-84. PubMed ID: 4684130
    [No Abstract]   [Full Text] [Related]  

  • 4. Renal blood flow measured by radioxenon 133: evaluation of a technique in dogs.
    Goluboff B; Bogash M; Cope C; Wolgin W; Isard HJ
    J Appl Physiol; 1969 Feb; 26(2):208-14. PubMed ID: 5765212
    [No Abstract]   [Full Text] [Related]  

  • 5. Evaluation of the xenon-133 renal blood flow method.
    Cosgrove MD; Mowat P
    Br J Urol; 1974 Apr; 46(2):134-47. PubMed ID: 4596073
    [No Abstract]   [Full Text] [Related]  

  • 6. Renal blood flow measurement with xenon-133 at the time of operation for renal artery stenosis.
    Lewis DH; Bergentz SE
    Surgery; 1966 Jun; 59(6):1043-9. PubMed ID: 5937950
    [No Abstract]   [Full Text] [Related]  

  • 7. Renal vascular volume, blood flow, and resistance in hypertension and renal arterial stenosis.
    Pedersen F; Ladefoged J
    Scand J Clin Lab Invest; 1969 Jun; 23(4):291-9. PubMed ID: 4910684
    [No Abstract]   [Full Text] [Related]  

  • 8. Comparison of xenon-133 washout and renal venous flow in the isolated perfused canine kidney.
    Bovee KC; Berkowitz HD; Miller LD
    Am J Vet Res; 1972 Mar; 33(3):511-7. PubMed ID: 5014459
    [No Abstract]   [Full Text] [Related]  

  • 9. Comparison of xenon-133 washout curves from the kidney with direct measurement of renal venous outflow.
    Lewis DH; Fritjofsson A
    Scand J Urol Nephrol; 1968; 2(1):62-3. PubMed ID: 4893377
    [No Abstract]   [Full Text] [Related]  

  • 10. Evaluation of the measurement of the renal blood flow by the 133 Xe washout technique in dogs.
    Kahn RJ; Gottignies P; Vanherweghem JL; Lambert PP
    Rev Eur Etud Clin Biol; 1972 Apr; 17(4):389-94. PubMed ID: 4562452
    [No Abstract]   [Full Text] [Related]  

  • 11. The influence of renin on the intrarenal distribution of blood flow and autoregulation.
    Brech WJ; Sigmund E; Kadatz R; Weller R; Adam W; Franz HE
    Nephron; 1974; 12(1):44-58. PubMed ID: 4838010
    [No Abstract]   [Full Text] [Related]  

  • 12. Xenon-133 washout for measuring intrarenal blood flow in the micropuncture rat.
    Kinney MJ; Quinones J; Rudich S; DiScala V
    Am J Physiol; 1974 Sep; 227(3):657-64. PubMed ID: 4416918
    [No Abstract]   [Full Text] [Related]  

  • 13. A method of intrarenal blood flow measurement using xenon-133 in the intact rat.
    Butt TJ; Bolli P; Jones DR; Wallis AT; Simpson FO
    Am J Physiol; 1979 Sep; 237(3):H395-9. PubMed ID: 382873
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Non-uniform blood flow in the left ventricular wall of dogs measured by the Xe-133 wash-out technique.
    Andersen H; Bagger H; Gotzsche H
    Acta Physiol Scand; 1969 Jul; 76(3):376-82. PubMed ID: 5823869
    [No Abstract]   [Full Text] [Related]  

  • 15. [Measurement of global renal blood flow after the analysis of the Xe 133 elution curve].
    Kahn RJ; Gottignies P; Vanherweghem JL; Lambert PP
    J Urol Nephrol (Paris); 1971; 77(4):364-7. PubMed ID: 4933964
    [No Abstract]   [Full Text] [Related]  

  • 16. A comparison of the disappearance curves of 133X3 and 85Kr for the measurement of the intrarenal distribution of blood flow.
    Carrière S
    Can J Physiol Pharmacol; 1970 Dec; 48(12):834-7. PubMed ID: 5514972
    [No Abstract]   [Full Text] [Related]  

  • 17. Comparative measurement of renal blood flow by xenon-133 clearance and electromagnetic flowmeter methods.
    Newman MH; Skinner DB
    Am Surg; 1969 Dec; 35(12):879-85. PubMed ID: 5355249
    [No Abstract]   [Full Text] [Related]  

  • 18. Values for intrarenal distribution of blood flow using xenon-133 in the anesthetized dog.
    Bovee KC; Webster GD
    Am J Vet Res; 1972 Mar; 33(3):501-9. PubMed ID: 5014458
    [No Abstract]   [Full Text] [Related]  

  • 19. Renal blood flow in patients with hypertension.
    Lasefoged J; Pedersen F
    Clin Sci; 1969 Oct; 37(2):253-62. PubMed ID: 5358990
    [No Abstract]   [Full Text] [Related]  

  • 20. Characteristics of blood flow in branches of the renal artery.
    Harvey RB
    Am J Physiol; 1963 Nov; 205(5):977-81. PubMed ID: 5877428
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 7.