These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
143 related articles for article (PubMed ID: 5055676)
1. Low exposure to asbestos. Gas exchange in ship pipe coverers and controls. Murphy RL; Gaensler EA; Redding RA; Belleau R; Keelan PJ; Smith AA; Goff AM; Ferris BG Arch Environ Health; 1972 Oct; 25(4):253-64. PubMed ID: 5055676 [No Abstract] [Full Text] [Related]
2. Pulmonary function testing in industry. Weill H J Occup Med; 1973 Sep; 15(9):693-9. PubMed ID: 4731662 [No Abstract] [Full Text] [Related]
3. Diagnosis of "asbestosis". Observations from a longitudinal survey of shipyard pipe coverers. Murphy RL; Gaensler EA; Ferris BG; Fitzgerald M; Solliday N; Morrisey W Am J Med; 1978 Sep; 65(3):488-98. PubMed ID: 717415 [No Abstract] [Full Text] [Related]
4. Association between increased small airway obstruction and asbestos exposure in patients with asbestosis. Yang X; Yan Y; Xue C; Du X; Ye Q Clin Respir J; 2018 Apr; 12(4):1676-1684. PubMed ID: 29087047 [TBL] [Abstract][Full Text] [Related]
5. Early effects of asbestos exposure on lung function. Jodoin G; Gibbs GW; Macklem PT; McDonald JC; Becklake MR Am Rev Respir Dis; 1971 Oct; 104(4):525-35. PubMed ID: 5094050 [No Abstract] [Full Text] [Related]
6. Diffusing capacity and over-all ventilation:perfusion in asthma. Weitzman RH; Wilson AF Am J Med; 1974 Nov; 57(5):767-74. PubMed ID: 4440700 [No Abstract] [Full Text] [Related]
7. The relative importance of clinical, radiological and pulmonary function variables in evaluating asbestosis and chronic obstructive airway disease in asbestos workers. Regan GM; Tagg B; Walford J; Thomson ML Clin Sci; 1971 Dec; 41(6):569-82. PubMed ID: 5131087 [No Abstract] [Full Text] [Related]
8. Effects of low concentrations of asbestos. Clinical, environmental, radiologic and epidemiologic observations in shipyard pipe coverers and controls. Murphy RL; Ferris BG; Burgess WA; Worcester J; Gaensler EA N Engl J Med; 1971 Dec; 285(23):1271-8. PubMed ID: 5113726 [No Abstract] [Full Text] [Related]
9. Ventilation, gas exchange and breathing mechanics during respirator treatment. Influence of respiratory frequency and minute volume. Hedenstierna G Scand J Respir Dis; 1972; 53(1):10-26. PubMed ID: 5052344 [No Abstract] [Full Text] [Related]
10. Lung diffusing capacity relates better to short-term progression on HRCT abnormalities than spirometry in mild asbestosis. Nogueira CR; Nápolis LM; Bagatin E; Terra-Filho M; Müller NL; Silva CI; Rodrigues RT; Neder JA; Nery LE Am J Ind Med; 2011 Mar; 54(3):185-93. PubMed ID: 21298694 [TBL] [Abstract][Full Text] [Related]
11. Diffusing capacity for carbon monoxide as a predictor of gas exchange during exercise. Sue DY; Oren A; Hansen JE; Wasserman K N Engl J Med; 1987 May; 316(21):1301-6. PubMed ID: 3574401 [TBL] [Abstract][Full Text] [Related]
12. Respiratory function tests for a clinician. Prime FJ BTTA Rev; 1973 Mar; 3(1):1-12. PubMed ID: 4585927 [No Abstract] [Full Text] [Related]
13. Prevalence of chronic respiratory disease. Asbestosis in ship repair workers. Ferris BG; Panadive MV; Peters JM; Murphy RL; Burgess WA; Bendergrass HP Arch Environ Health; 1971 Sep; 23(3):220-5. PubMed ID: 5123156 [No Abstract] [Full Text] [Related]
14. Pulmonary function of nonsmoking female asbestos workers without radiographic signs of asbestosis. Wang XR; Yano E; Nonaka K; Wang M; Wang Z Arch Environ Health; 1998; 53(4):292-8. PubMed ID: 9709994 [TBL] [Abstract][Full Text] [Related]
16. Lung function studies in asbestos workers. Muldoon BC; Turner-Warwick M Br J Dis Chest; 1972 Apr; 66(2):121-32. PubMed ID: 5035589 [No Abstract] [Full Text] [Related]
17. Parenchymal asbestosis due to primary asbestos exposure among ship-breaking workers: report of the first cases from Bangladesh. Muralidhar V; Ahasan MF; Khan AM BMJ Case Rep; 2017 Nov; 2017():. PubMed ID: 29102973 [TBL] [Abstract][Full Text] [Related]
18. Breathing mechanics and gas exchange in normal subjects during artificial ventilation. Influence of respiratory frequency and minute volume. Hedenstierna G; Löfström JB Scand J Respir Dis; 1972; 53(3):135-48. PubMed ID: 4559606 [No Abstract] [Full Text] [Related]
19. Dynamic and static lung volumes, blood gas tensions, and diffusing capacity in patients with cystic fibrosis. Featherby EA; Weng TR; Crozier DN; Duic A; Reilly BJ; Levison H Am Rev Respir Dis; 1970 Nov; 102(5):737-49. PubMed ID: 5475672 [No Abstract] [Full Text] [Related]