These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

86 related articles for article (PubMed ID: 5063650)

  • 1. Corrosion of Ti-6A1-4V in simulated body fluids and bovine plasma.
    Aragon PJ; Hulbert SF
    J Biomed Mater Res; 1972 May; 6(3):155-64. PubMed ID: 5063650
    [No Abstract]   [Full Text] [Related]  

  • 2. Anodic polarization behavior of Ti-Ni and Ti-6A1-4V in simulated physiological solutions.
    Speck KM; Fraker AC
    J Dent Res; 1980 Oct; 59(10):1590-5. PubMed ID: 6932415
    [TBL] [Abstract][Full Text] [Related]  

  • 3. In vitro corrosion of Ti-6Al-4V and type 316L stainless steel when galvanically coupled with carbon.
    Thompson NG; Buchanan RA; Lemons JE
    J Biomed Mater Res; 1979 Jan; 13(1):35-44. PubMed ID: 429383
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Surface mechanical properties, corrosion resistance, and cytocompatibility of nitrogen plasma-implanted nickel-titanium alloys: a comparative study with commonly used medical grade materials.
    Yeung KW; Poon RW; Chu PK; Chung CY; Liu XY; Lu WW; Chan D; Chan SC; Luk KD; Cheung KM
    J Biomed Mater Res A; 2007 Aug; 82(2):403-14. PubMed ID: 17295246
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Galvanic corrosion behavior of orthodontic archwire alloys coupled to bracket alloys.
    Iijima M; Endo K; Yuasa T; Ohno H; Hayashi K; Kakizaki M; Mizoguchi I
    Angle Orthod; 2006 Jul; 76(4):705-11. PubMed ID: 16808581
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of metal release from various metallic biomaterials in vitro.
    Okazaki Y; Gotoh E
    Biomaterials; 2005 Jan; 26(1):11-21. PubMed ID: 15193877
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Polarization studies of surgical materials in Ringer's solution.
    Mueller HJ; Greener EH
    J Biomed Mater Res; 1970 Mar; 4(1):29-41. PubMed ID: 5434814
    [No Abstract]   [Full Text] [Related]  

  • 8. Monitoring of titanium base alloys-biofluids interface.
    Popa MV; Demetrescu I; Suh SH; Vasilescu E; Drob P; Ionita D; Vasilescu C
    Bioelectrochemistry; 2007 Nov; 71(2):126-34. PubMed ID: 17409027
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Is galvanic corrosion between titanium alloy and stainless steel spinal implants a clinical concern?
    Serhan H; Slivka M; Albert T; Kwak SD
    Spine J; 2004; 4(4):379-87. PubMed ID: 15246296
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Electrochemical behavior of Ti-6Al-4V alloy in static biosimulating solutions.
    Lewis G; Daigle K
    J Appl Biomater; 1993; 4(1):47-54. PubMed ID: 10148345
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Reduced corrosion of CP Ti and Ti-6A1-4V alloy endosseous dental implants after glow-discharge treatment: a preliminary report.
    Vargas E; Baier RE; Meyer AE
    Int J Oral Maxillofac Implants; 1992; 7(3):338-44. PubMed ID: 1289259
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of the in vivo and in vitro corrosion of 18-8 stainless steel and titanium.
    Revie RW; Greene ND
    J Biomed Mater Res; 1969 Sep; 3(3):465-70. PubMed ID: 5350518
    [No Abstract]   [Full Text] [Related]  

  • 13. Electrochemical corrosion of titanium and titanium-based alloys.
    Kuphasuk C; Oshida Y; Andres CJ; Hovijitra ST; Barco MT; Brown DT
    J Prosthet Dent; 2001 Feb; 85(2):195-202. PubMed ID: 11208211
    [TBL] [Abstract][Full Text] [Related]  

  • 14. An investigation into the effects of polishing on surface hardness and corrosion of orthodontic archwires.
    Hunt NP; Cunningham SJ; Golden CG; Sheriff M
    Angle Orthod; 1999 Oct; 69(5):433-40. PubMed ID: 10515141
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Anodized titanium and stainless steel in contact with CFRP: an electrochemical approach considering galvanic corrosion.
    Mueller Y; Tognini R; Mayer J; Virtanen S
    J Biomed Mater Res A; 2007 Sep; 82(4):936-46. PubMed ID: 17335021
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Wear-corrosion performance of Si-DLC coatings on Ti-6Al-4V substrate.
    Kim JG; Lee KR; Yang SJ
    J Biomed Mater Res A; 2008 Jul; 86(1):41-7. PubMed ID: 17941020
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Stability of cp-Ti and Ti-6Al-4V alloy for dental implants as a function of saliva pH - an electrochemical study.
    Barão VA; Mathew MT; Assunção WG; Yuan JC; Wimmer MA; Sukotjo C
    Clin Oral Implants Res; 2012 Sep; 23(9):1055-62. PubMed ID: 22092540
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Corrosion of anodic TiO coatings on Ti-6Al-4V in simulated body fluid.
    Narayanan R; Seshadri SK; Kwon TY; Kim KH
    J Biomed Mater Res A; 2008 Aug; 86(2):502-9. PubMed ID: 17975823
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Corrosion resistance of a laser spot-welded joint of NiTi wire in simulated human body fluids.
    Yan XJ; Yang DZ
    J Biomed Mater Res A; 2006 Apr; 77(1):97-102. PubMed ID: 16392124
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Electrochemical study of Type 304 and 316L stainless steels in simulated body fluids and cell cultures.
    Tang YC; Katsuma S; Fujimoto S; Hiromoto S
    Acta Biomater; 2006 Nov; 2(6):709-15. PubMed ID: 16935040
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.