BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

99 related articles for article (PubMed ID: 5074091)

  • 1. Gait analysis and tissue-socket interface pressures in above-knee amputees.
    Leavitt LA; Zuniga EN; Calvert JC; Canzoneri J; Peterson CR
    South Med J; 1972 Oct; 65(10):1197-207. PubMed ID: 5074091
    [No Abstract]   [Full Text] [Related]  

  • 2. Conventional patellar-tendon-bearing (PTB) socket/stump interface dynamic pressure distributions recorded during the prosthetic stance phase of gait of a trans-tibial amputee.
    Convery P; Buis AW
    Prosthet Orthot Int; 1998 Dec; 22(3):193-8. PubMed ID: 9881607
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Stump-socket interface pressure as an aid to socket design in prostheses for trans-femoral amputees--a preliminary study.
    Lee VS; Solomonidis SE; Spence WD
    Proc Inst Mech Eng H; 1997; 211(2):167-80. PubMed ID: 9184457
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Relationship between socket pressure and EMG of two muscles in trans-femoral stumps during gait.
    Hong JH; Mun MS
    Prosthet Orthot Int; 2005 Apr; 29(1):59-72. PubMed ID: 16180378
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Energy expenditure in below-knee amputees: correlation with stump length.
    Gonzalez EG; Corcoran PJ; Reyes RL
    Arch Phys Med Rehabil; 1974 Mar; 55(3):111-9. PubMed ID: 4817680
    [No Abstract]   [Full Text] [Related]  

  • 6. Pressure characteristics at the stump/socket interface in transtibial amputees using an adaptive prosthetic foot.
    Wolf SI; Alimusaj M; Fradet L; Siegel J; Braatz F
    Clin Biomech (Bristol, Avon); 2009 Dec; 24(10):860-5. PubMed ID: 19744755
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Principles of teaching below-knee amputees to walk including weaning from canes].
    Hämmerle R
    Ther Umsch; 1983 Jan; 40(1):28-33. PubMed ID: 6845235
    [No Abstract]   [Full Text] [Related]  

  • 8. Estimation of forces at the interface between an artificial limb and an implant directly fixed into the femur in above-knee amputees.
    Stephenson P; Seedhom BB
    J Orthop Sci; 2002; 7(3):292-7. PubMed ID: 12077652
    [TBL] [Abstract][Full Text] [Related]  

  • 9. An experimental study of the interface pressure profile during level walking of a new suspension system for lower limb amputees.
    Eshraghi A; Abu Osman NA; Gholizadeh H; Ali S; Sævarsson SK; Wan Abas WA
    Clin Biomech (Bristol, Avon); 2013 Jan; 28(1):55-60. PubMed ID: 23157843
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Principles of teaching above-knee amputees to walk].
    Hämmerle R
    Ther Umsch; 1983 Jan; 40(1):39-46. PubMed ID: 6845237
    [No Abstract]   [Full Text] [Related]  

  • 11. SOCKET FLEXION AND GAIT OF AN ABOVE-KNEE, BILATERAL AMPUTEE.
    PEIZER E
    Artif Limbs; 1963; 7():43-9. PubMed ID: 14073469
    [No Abstract]   [Full Text] [Related]  

  • 12. An open socket technique for through-knee amputations in relation to skin problems of the stump: an explorative study.
    Otter N; Postema K; Rijken RA; van Limbeek J
    Clin Rehabil; 1999 Feb; 13(1):34-43. PubMed ID: 10327095
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Loads on the prosthesis-socket interface of above-knee amputees during normal gait: validation of a multi-body simulation.
    Schwarze M; Hurschler C; Seehaus F; Oehler S; Welke B
    J Biomech; 2013 Apr; 46(6):1201-6. PubMed ID: 23473441
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Roentgenological study of certain stump-socket relationships in above-knee amputees with special regard to tissue proportions, socket fit and attachment stability.
    Erikson U; James U
    Ups J Med Sci; 1973 Jul; 78(3):203-14. PubMed ID: 4766848
    [No Abstract]   [Full Text] [Related]  

  • 15. Effect on gait and socket comfort in unilateral trans-tibial amputees after exchange to a polyurethane concept.
    Aström I; Stenström A
    Prosthet Orthot Int; 2004 Apr; 28(1):28-36. PubMed ID: 15171575
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of liner materials on interface pressures in below-knee prostheses.
    Sonck WA; Cockrell JL; Koepke GH
    Arch Phys Med Rehabil; 1970 Nov; 51(11):666-9. PubMed ID: 5501936
    [No Abstract]   [Full Text] [Related]  

  • 17. Letter: A new leg-prosthesis socket.
    Goldie I; Eeg-Olofsson T; Rehnström P; Eliasson T
    Lancet; 1974 Jun; 1(7868):1224. PubMed ID: 4134923
    [No Abstract]   [Full Text] [Related]  

  • 18. Quantitative method to measure the relationship between prosthetic gait and the forces produced at the stump-socket interface.
    Leavitt LA; Peterson CR; Canzoneri J; Paz R; Muilenburg AL; Rhyne VT
    Am J Phys Med; 1970 Jun; 49(3):192-203. PubMed ID: 5421658
    [No Abstract]   [Full Text] [Related]  

  • 19. Influence of malalignment on socket reaction moments during gait in amputees with transtibial prostheses.
    Boone DA; Kobayashi T; Chou TG; Arabian AK; Coleman KL; Orendurff MS; Zhang M
    Gait Posture; 2013 Apr; 37(4):620-6. PubMed ID: 23177920
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Socket/stump interface dynamic pressure distributions recorded during the prosthetic stance phase of gait of a trans-tibial amputee wearing a hydrocast socket.
    Convery P; Buis AW
    Prosthet Orthot Int; 1999 Aug; 23(2):107-12. PubMed ID: 10493137
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.