These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
247 related articles for article (PubMed ID: 5084244)
1. A new gas permeable membrane for blood oxygenators. Eiseman B; Birnbaum D; Leonard R; Martinez FJ Surg Gynecol Obstet; 1972 Nov; 135(5):732-6. PubMed ID: 5084244 [No Abstract] [Full Text] [Related]
2. Development and evaluation of a new hollow-fiber membrane oxygenator. Dutton RC; Mather FW; Walker SN; Lipps BJ; Rudy LW; Severinghaus JW; Edmunds LH Trans Am Soc Artif Intern Organs; 1971; 17():331-6. PubMed ID: 5158114 [No Abstract] [Full Text] [Related]
3. Evaluation of hollow fiber and spiral coil membrane oxygenators designed for cardiopulmonary bypass in infants. Rawitscher RE; Dutton RC; Edmunds LH Circulation; 1973 Jul; 48(1 Suppl):III105-11. PubMed ID: 4198469 [No Abstract] [Full Text] [Related]
4. [The use of a membrane oxygenator in respiratory assistance. II. Animal experiments and therapeutic trials of CO 2 removal in respiratory insufficiency]. Gille JP; Gautier P; Horsky P; Sadoul P Bull Physiopathol Respir (Nancy); 1972; 8(1):29-48. PubMed ID: 5052520 [No Abstract] [Full Text] [Related]
5. Prolonged extracorporeal respiration with a membrane gas exchanger. Awad JA; Matte J; Brassard A J Thorac Cardiovasc Surg; 1973 Jul; 66(1):40-51. PubMed ID: 4715384 [No Abstract] [Full Text] [Related]
6. Experimental large volume hemodilution with plasma. Gadboys HL; Litwak RS; Wallace HW; Kahn M; Kochwa S; Buerger W J Thorac Cardiovasc Surg; 1966 Jul; 52(1):112-20. PubMed ID: 5943106 [No Abstract] [Full Text] [Related]
7. Laboratory evaluation of a new silicone membrane oxygenator. Birnbaum D; Eiseman B J Thorac Cardiovasc Surg; 1972 Sep; 64(3):441-51. PubMed ID: 5074838 [No Abstract] [Full Text] [Related]
9. [Regulation of gas metabolism in the oxygenators of artificial circulation apparatus]. Fridman VE; Osipov VP Med Tekh; 1972; 5():9-15. PubMed ID: 4663472 [No Abstract] [Full Text] [Related]
10. Liquid-liquid oxygenation: a new approach. Wallace HW; Asher WJ; Li NN Trans Am Soc Artif Intern Organs; 1973; 19():80-6. PubMed ID: 4722781 [No Abstract] [Full Text] [Related]
12. The use of proteic and enzymatic coatings and-or membranes for oxygenators. Broun G; Canh-Tran-Minh ; Thomas D; Domurado D; Selegny E Trans Am Soc Artif Intern Organs; 1971; 17():341-9. PubMed ID: 5003423 [No Abstract] [Full Text] [Related]
13. Gas transfer and thrombogenesis in an annular membrane oxygenator with active blood mixing. Gaylor JD; Murphy JF; Caprini JA; Zukerman L; Mockros LF Trans Am Soc Artif Intern Organs; 1973; 19():516-24. PubMed ID: 4805841 [No Abstract] [Full Text] [Related]
14. [Current status of the artificial lung]. Galletti PM Bull Physiopathol Respir (Nancy); 1972; 8(1):1-6. PubMed ID: 4559556 [No Abstract] [Full Text] [Related]
15. Development of an implantable artificial lung. Palmer AS; Collins J; Head LR J Thorac Cardiovasc Surg; 1973 Oct; 66(4):521-5. PubMed ID: 4755443 [No Abstract] [Full Text] [Related]
16. BIOLOGIC EVALUATION OF BLOOD AFTER PROLONGED RECIRCULATION THROUGH FILM AND MEMBRANE OXYGENATORS. DOBELL AR; GALVA R; SARKOZY E; MURPHY DR Ann Surg; 1965 Apr; 161(4):617-22. PubMed ID: 14274872 [No Abstract] [Full Text] [Related]
17. Improving the efficiency of a tubular membrane oxygenator. Zingg W; Matthews EI Med Prog Technol; 1976; 4(3):139-45. PubMed ID: 1018702 [TBL] [Abstract][Full Text] [Related]
18. The effects of solid and hollow fiber screens on gas exchange in membrane oxygenators. Eberhart RC; Curtis RM Trans Am Soc Artif Intern Organs; 1973; 19():66-71. PubMed ID: 4737353 [No Abstract] [Full Text] [Related]