These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

107 related articles for article (PubMed ID: 5090003)

  • 1. Attenuation of 4-32 MV x-rays in ordinary concrete, heavy concrete, iron and lead.
    Maruyama T; Kumamoto Y; Kato Y; Hashizume T; Yamamoto M
    Health Phys; 1971 Mar; 20(3):277-84. PubMed ID: 5090003
    [No Abstract]   [Full Text] [Related]  

  • 2. Measurements on the attenuation of 4 MV x rays in barytes concrete.
    Ormsby PL; Roberts GC
    Br J Radiol; 1968 Mar; 41(483):235-6. PubMed ID: 4966727
    [No Abstract]   [Full Text] [Related]  

  • 3. Tenth value layers for 60Co gamma rays and for 4, 6, 10, 15, and 18 MV x rays in concrete for beams of cone angles between 0 degrees and 14 degrees calculated by Monte Carlo simulation.
    Jaradat AK; Biggs PJ
    Health Phys; 2007 May; 92(5):456-63. PubMed ID: 17429304
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Measurements of neutron effective doses and attenuation lengths for shielding materials at the heavy-ion medical accelerator in Chiba.
    Kumamoto Y; Noda Y; Sato Y; Kanai T; Murakami T
    Health Phys; 2005 May; 88(5):469-79. PubMed ID: 15824595
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Obliquity factors for 60 Co and 4, 10, and 18 MV x rays for concrete, steel, and lead and angles of incidence between 0 and 70 degrees.
    Biggs PJ
    Health Phys; 1996 Apr; 70(4):527-36. PubMed ID: 8617593
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Attenuation in Lipowitz's metal of x rays produced at 2, 4, 10, and 18 MV and gamma rays from cobalt-60.
    Huen A; Findley DO; Skov DD
    Med Phys; 1979; 6(2):147-8. PubMed ID: 460064
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Albedos for 4-, 10-, and 18-MV bremsstrahlung x-ray beams on concrete, iron, and lead--normally incident.
    Lo YC
    Med Phys; 1992; 19(3):659-66. PubMed ID: 1324391
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Analysis of tenth-value-layers for common shielding materials for a robotically mounted stereotactic radiosurgery machine.
    Rodgers JE
    Health Phys; 2007 Apr; 92(4):379-86. PubMed ID: 17351503
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Neutron attenuation characteristics of polyethylene, polyvinyl chloride, and heavy aggregate concrete and mortars.
    Abdul-Majid S; Othman F
    Health Phys; 1994 Mar; 66(3):327-38. PubMed ID: 8106253
    [TBL] [Abstract][Full Text] [Related]  

  • 10. High-performance heavy concrete as a multi-purpose shield.
    Mortazavi SM; Mosleh-Shirazi MA; Roshan-Shomal P; Raadpey N; Baradaran-Ghahfarokhi M
    Radiat Prot Dosimetry; 2010 Dec; 142(2-4):120-4. PubMed ID: 21036811
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Ulexite-galena intermediate-weight concrete as a novel design for overcoming space and weight limitations in the construction of efficient shields against neutrons and photons.
    Aghamiri SM; Mortazavi SM; Razi Z; Mosleh-Shirazi MA; Baradaran-Ghahfarokhi M; Rahmani F; Faeghi F
    Radiat Prot Dosimetry; 2013; 154(3):375-80. PubMed ID: 23019599
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Calculation of conversion coefficients for air kerma to ambient dose equivalent using transmitted spectra of megavoltage X-rays through concrete.
    Cordeiro TP; Silva AX
    Radiat Prot Dosimetry; 2012 Dec; 152(4):455-62. PubMed ID: 22683619
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Attenuation of primary and scatter radiation in concrete and steel for 18 MV X-rays from a Clinac-20 linear accelerator.
    Abrath FG; Bello J; Purdy JA
    Health Phys; 1983 Nov; 45(5):969-73. PubMed ID: 6417056
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Attenuation of primary and leakage radiation in concrete for X-rays from a 10 MV linear accelerator.
    Tochilin E; LaRiviere PD
    Health Phys; 1979 Mar; 36(3):387-92. PubMed ID: 489289
    [No Abstract]   [Full Text] [Related]  

  • 15. Measurements of 6 MV x-rays. I. Primary radiation absorption in lead, steel and concrete.
    Karzmark CJ; Capone T
    Br J Radiol; 1968 Jan; 41(481):33-9. PubMed ID: 5634450
    [No Abstract]   [Full Text] [Related]  

  • 16. Broad beam attenuation in concrete for 50 to 300-Kvp x-rays and in lead for 300 Kvp x-rays.
    TROUT ED; KELLEY JP; LUCAS AC
    Radiology; 1959 Jan; 72(1):62-7. PubMed ID: 13624054
    [No Abstract]   [Full Text] [Related]  

  • 17. Braod-beam attenuation in lead for x rays from 50 to 300 kVp.
    Kelley JP; Trout ED
    Radiology; 1972 Jul; 104(1):171-5. PubMed ID: 5033581
    [No Abstract]   [Full Text] [Related]  

  • 18. Evaluation of transmission data of diagnostic X rays through concrete using Monte Carlo simulation.
    Noto K; Koshida K; Iida H; Fukuda A
    Radiat Prot Dosimetry; 2009 Feb; 133(3):144-52. PubMed ID: 19307234
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Attenuation characteristics of MagnaDense high-density concrete at 6, 10 and 15 mv for use in radiotherapy bunker design.
    Jones MR; Peet DJ; Horton PW
    Health Phys; 2009 Jan; 96(1):67-75. PubMed ID: 19066488
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Shielding experiment of heavy-ion produced neutrons using a tissue-equivalent proportional counter.
    Nunomiya T; Yonai S; Takada M; Fukumura A; Nakamura T
    Radiat Prot Dosimetry; 2003; 106(3):207-18. PubMed ID: 14690321
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.