These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

274 related articles for article (PubMed ID: 5126676)

  • 1. Five-year experience with the Smeloff-Cutter mitral prosthesis.
    Fishman NH; Edmunds LH; Hutchinson JC; Roe BB
    J Thorac Cardiovasc Surg; 1971 Sep; 62(3):345-56. PubMed ID: 5126676
    [No Abstract]   [Full Text] [Related]  

  • 2. Mitral valve replacement with the Björk-Shiley tilting disc valve. A clinical and haemodynamic study in patients with isolated mitral valve lesions.
    Böök K
    Scand J Thorac Cardiovasc Surg Suppl; 1974; (12):1-28. PubMed ID: 4533363
    [No Abstract]   [Full Text] [Related]  

  • 3. Surgery of mitral valve disease.
    Thompson DT
    Cent Afr J Med; 1969 Feb; 15(2):30-6. PubMed ID: 5784636
    [No Abstract]   [Full Text] [Related]  

  • 4. Low profile bioprostheses for mitral valve replacement.
    Romano M; Sigal R; Lorente P; Piwnica A
    Z Kardiol; 1986; 75 Suppl 2():305-7. PubMed ID: 3727708
    [No Abstract]   [Full Text] [Related]  

  • 5. [Replacement of the mitral valve by the Starr-Edwards prosthesis].
    Vandenput F; Barrenechea JP; Ponlot R; Tremouroux J; Kremer R; Chalant C
    Acta Cardiol; 1971; 26(5):458-79. PubMed ID: 5316233
    [No Abstract]   [Full Text] [Related]  

  • 6. Surgery of the mitral valve: technical considerations and results.
    Cleland WP
    Proc R Soc Med; 1967 Oct; 60(10):1018-21. PubMed ID: 6057965
    [No Abstract]   [Full Text] [Related]  

  • 7. Mitral valve replacement--a review of five years' experience.
    Windsor HM; Shanahan MX
    Med J Aust; 1969 Feb; 1(6):259-63. PubMed ID: 5774911
    [No Abstract]   [Full Text] [Related]  

  • 8. Cardiac valve replacement. A seven-year follow-up.
    Aston SJ; Mulder DG
    J Thorac Cardiovasc Surg; 1971 Apr; 61(4):547-55. PubMed ID: 5549110
    [No Abstract]   [Full Text] [Related]  

  • 9. Twenty-seven-year follow up of the Starr-Edwards prosthesis implanted in the mitral position: an analysis of survival and valve-related complications.
    De Santo LS; Romano G; Petraio A; Della Corte A; Amarelli C; Nappi G; De Feo M; Scardone M; Cotrufo M
    J Heart Valve Dis; 2004 May; 13 Suppl 1():S21-5. PubMed ID: 15224995
    [No Abstract]   [Full Text] [Related]  

  • 10. Rheumatic valve disease in childhood and adolescence: surgical treatment.
    Levy MJ; Vidne B
    Chest; 1973 Jun; 63(6):933-6. PubMed ID: 4711864
    [No Abstract]   [Full Text] [Related]  

  • 11. [Postoperative mortality after mitral valve replacement].
    Rudolph W; Schinz A
    Thoraxchir Vask Chir; 1972 Oct; 20(5):339-46. PubMed ID: 4539099
    [No Abstract]   [Full Text] [Related]  

  • 12. Hemodynamic changes following mitral valve replacement with the Starr-Edwards and Cutter-Smeloff prostheses.
    Lee SJ; Zaragoza AJ; Callaghan JC; Rossall RE; Fraser RS
    J Thorac Cardiovasc Surg; 1971 May; 61(5):688-98. PubMed ID: 5578272
    [No Abstract]   [Full Text] [Related]  

  • 13. [Results of replacement of the mitral apparatus (40 prostheses)].
    Ben Naceur M; Slimane ML; Zaiem A; Slimane H
    Tunis Med; 1978; 56(3):203-4. PubMed ID: 751296
    [No Abstract]   [Full Text] [Related]  

  • 14. Long-term follow-up after mitral valve replacement in childhood: poor event-free survival in the young child.
    Beierlein W; Becker V; Yates R; Tsang V; Elliott M; de Leval M; van Doorn C
    Eur J Cardiothorac Surg; 2007 May; 31(5):860-5. PubMed ID: 17383889
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Hemodynamic evaluation of the Beall mitral valve prosthesis.
    Reid JA; Stevens TW; Sigwart U; Fulweber RC; Alexander JK
    Circulation; 1972 May; 45(1 Suppl):I1-7. PubMed ID: 5025052
    [No Abstract]   [Full Text] [Related]  

  • 16. [Mitral prosthesis with hinged disk (4 years and 6 months of experience)].
    Servelle M; Pernod J; Bacour F; Kermarec J; Couespel R; Haguenauer G; Cornu C; Zafari I; Andrieux J
    Arch Mal Coeur Vaiss; 1972 May; 65(5):583-92. PubMed ID: 4632157
    [No Abstract]   [Full Text] [Related]  

  • 17. Cardiac valve replacement with Wada-Cutter prosthesis.
    Wada J; Komatsu S; Kamata K
    Ann Thorac Surg; 1972 Jul; 14(1):38-46. PubMed ID: 4557162
    [No Abstract]   [Full Text] [Related]  

  • 18. [Follow-up results 5 years after aortic valve replacement with a Smeloff-Cutter prosthesis. Apropos of 200 cases].
    Soyer R; Brunet A; Redonnet M; Hubscher C; Letac B
    Arch Mal Coeur Vaiss; 1983 Apr; 76(4):391-9. PubMed ID: 6223609
    [No Abstract]   [Full Text] [Related]  

  • 19. [2 cases of fatal complication of the Smeloff-Cutter mitral prosthesis].
    Ibarra-Pérez C; Hernández Osorio C; Rodríguez Trujillo F; Pérez Redondo H
    Arch Inst Cardiol Mex; 1970; 40(6):782-4. PubMed ID: 5504980
    [No Abstract]   [Full Text] [Related]  

  • 20. Experience with the Wada-Cutter valve prosthesis in the aortic area. One-year follow-up.
    Björk VO
    J Thorac Cardiovasc Surg; 1970 Jul; 60(1):26-33. PubMed ID: 4912965
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 14.