These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

91 related articles for article (PubMed ID: 512855)

  • 1. Modification of metoclopramide GLC assay: application to human biological specimens.
    Tam YK; Axelson JE; Ongley R
    J Pharm Sci; 1979 Oct; 68(10):1254-6. PubMed ID: 512855
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Sensitive electron-capture GLC determination of metoclopramide in biological fluids.
    Tam YK; Axelson JE
    J Pharm Sci; 1978 Aug; 67(8):1073-7. PubMed ID: 671240
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Electron-capture determination of metoclopramide in biological fluids using fused silica capillary columns. Application to placental transport studies in sheep and humans.
    Riggs KW; Axelson JE; Rurak DW; Hasman DA; McErlane B; Bylsma-Howell M; McMorland GH; Ongley R; Price JD
    J Chromatogr; 1983 Sep; 276(2):319-28. PubMed ID: 6630381
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Liquid chromatographic analysis of alizapride and metoclopramide in human plasma and urine using solid-phase extraction.
    de Jong AP; Wittebrood AJ; du Châtinier WM; Bron J
    J Chromatogr; 1987 Aug; 419():233-42. PubMed ID: 3667781
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Determination of bromopride in human plasma and urine by high-performance liquid chromatography.
    Brodie RR; Chasseaud LF; Rooney L
    J Chromatogr; 1984 Oct; 310(2):353-60. PubMed ID: 6511853
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Electron-capture gas chromatographic assay for metoclopramide in plasma.
    Ross-Lee LM; Eadie MJ; Bochner F; Hooper WD; Tyrer JH
    J Chromatogr; 1980 Aug; 183(2):175-84. PubMed ID: 7400276
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Determination of metoclopramide and its glucuronide and sulphate conjugates in human biological fluids (plasma, urine and bile) by ion-pair high-performance liquid chromatography.
    Takahashi H; Ogata H; Echizen H; Ishizaki T
    J Chromatogr; 1987 Aug; 419():243-51. PubMed ID: 3667782
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Determination of metoclopramide and two of its metabolites using a sensitive and selective gas chromatographic-mass spectrometric assay.
    Riggs KW; Szeitz A; Rurak DW; Mutlib AE; Abbott FS; Axelson JE
    J Chromatogr B Biomed Appl; 1994 Oct; 660(2):315-25. PubMed ID: 7866522
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A rapid liquid chromatographic method for the determination of metoclopramide in human plasma.
    Buss DC; Hutchings AD; Scott S; Routledge PA
    Ther Drug Monit; 1990 May; 12(3):293-6. PubMed ID: 2349616
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Quantitation of a novel antiemetic (ADR-851) in plasma and urine by reversed-phase high-performance liquid chromatography with fluorescence detection.
    Rossi DT; Overmyer SK; Lewis RC; Narang PK
    J Chromatogr; 1991 May; 566(1):257-65. PubMed ID: 1885720
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Metoclopramide kinetics in patients with impaired renal function and clearance by hemodialysis.
    Lehmann CR; Heironimus JD; Collins CB; O'Neil TJ; Pierson WP; Crowe JT; Melikian AP; Wright GJ
    Clin Pharmacol Ther; 1985 Mar; 37(3):284-9. PubMed ID: 3971652
    [TBL] [Abstract][Full Text] [Related]  

  • 12. High-pressure liquid chromatographic method for determination of metoclopramide in serum, urine, and saliva, with a pharmacokinetic study in patients.
    Popović J
    Ther Drug Monit; 1984; 6(1):77-82. PubMed ID: 6710558
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Sensitive electron-capture gas-liquid chromatographic assay for the de-ethylated metabolite of metoclopramide.
    Tam YK; Axelson JE
    J Chromatogr; 1979 Feb; 170(1):157-63. PubMed ID: 544617
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Determination of metoclopramide in the serum and urine of cattle.
    Jones RD; Bowen JM
    Vet Hum Toxicol; 1991 Dec; 33(6):551-3. PubMed ID: 1808828
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Novel molecularly imprinted polymers for the selective extraction and determination of metoclopramide in human serum and urine samples using high-performance liquid chromatography.
    Javanbakht M; Shaabani N; Akbari-Adergani B
    J Chromatogr B Analyt Technol Biomed Life Sci; 2009 Aug; 877(24):2537-44. PubMed ID: 19604730
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Preliminary pharmacokinetics of metoclopramide in humans. Plasma levels following a single oral and intravenous dose (author's transl)].
    Schuppan D; Schmidt I; Heller M
    Arzneimittelforschung; 1979; 29(1):151-4. PubMed ID: 582108
    [TBL] [Abstract][Full Text] [Related]  

  • 17. High plasma concentrations of metoclopramide are not detected by radioreceptor assay.
    Stanley M; Wazer D
    Neuropsychobiology; 1983; 10(2-3):108-10. PubMed ID: 6674818
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Determination of metoclopramide in human plasma using hydrophilic interaction chromatography with tandem mass spectrometry.
    Lee HW; Ji HY; Kim HY; Park ES; Lee KC; Lee HS
    J Chromatogr B Analyt Technol Biomed Life Sci; 2009 Jun; 877(18-19):1716-20. PubMed ID: 19442594
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The pharmacokinetics of metoclopramide in man with observations in the dog.
    Bateman DN; Kahn C; Davies DS
    Br J Clin Pharmacol; 1980 Apr; 9(4):371-7. PubMed ID: 7378253
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Bioavailability of controlled-release metoclopramide. 2nd communication: multiple dose study.
    Beckett AH; Behrendt WA; Hadzija BW
    Arzneimittelforschung; 1987 Feb; 37(2):224-8. PubMed ID: 3580027
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.