These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

89 related articles for article (PubMed ID: 5144078)

  • 1. [A new pulse recorder for the quantitative registration of the apex cardiogram].
    Witte J; Heublein B
    Dtsch Gesundheitsw; 1971 Oct; 26(43):2047-9. PubMed ID: 5144078
    [No Abstract]   [Full Text] [Related]  

  • 2. Apex-carotis diagram in ischemic heart disease with angina pectoris.
    Kolev NS
    Med Interne; 1978; 16(2):197-202. PubMed ID: 663536
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Some preliminary observations on the correlation of the high frequency (acceleration) direct-body ballistocardiogram with the apex cardiogram, carotid pulse and their derivatives.
    Winer NJ
    Bibl Cardiol; 1972; 29():74-85. PubMed ID: 5075222
    [No Abstract]   [Full Text] [Related]  

  • 4. [The apex cardiogram in the diagnosis of angina pectoris].
    Palazzuoli V; Mondillo S
    Boll Soc Ital Cardiol; 1980; 25(2):165-71. PubMed ID: 7236441
    [No Abstract]   [Full Text] [Related]  

  • 5. The exercise apex cardiogram: a clinical test in angina pectoris.
    Dimond EG
    Am J Cardiol; 1971 Jan; 27(1):120-1. PubMed ID: 5538706
    [No Abstract]   [Full Text] [Related]  

  • 6. [The 1st derivative of the apex cardiogram (delta-ACG) in polycardiographic technic].
    Zanardi F; Farinelli A; Longhini C; Degli Atti B; Alvisi V
    Boll Soc Ital Cardiol; 1968; 13(4):492-503. PubMed ID: 5733167
    [No Abstract]   [Full Text] [Related]  

  • 7. [Study of cardiac performance with bloodless methods. First lead of the apex-cardiogram and the carotidogram].
    Sîrbulescu R; Chirilă-Prisca L; Cîrjeu L
    Med Interna (Bucur); 1972 Feb; 24(2):215-28. PubMed ID: 5022573
    [No Abstract]   [Full Text] [Related]  

  • 8. EFFECTS OF COLD AIR, SMOKING ON CARDIAC FUNCTION STUDIED WITH APEX CARDIOGRAM.
    HARRISON WE; LOUIS HJ
    JAMA; 1964 Mar; 187():SUPPL 29-30. PubMed ID: 14102951
    [No Abstract]   [Full Text] [Related]  

  • 9. [Instrumental problems with the apex cardiogram].
    Sakamoto T
    J Cardiol; 1995 May; 25(5):269-72. PubMed ID: 7776197
    [No Abstract]   [Full Text] [Related]  

  • 10. [Effect of isoproterenol on the apex cardiogram and carotid pulse in healthy patients].
    Mahlich J
    Z Kreislaufforsch; 1968 Oct; 57(10):911-9. PubMed ID: 5721677
    [No Abstract]   [Full Text] [Related]  

  • 11. [Use of a piezoresistant transducer for taking and recording an apex cardiogram].
    Kosmăk I; Zeman V; Parácek M
    Sb Ved Pr Lek Fak Karlovy Univerzity Hradci Kralove Suppl; 1981; 24(5):663-8. PubMed ID: 6983122
    [No Abstract]   [Full Text] [Related]  

  • 12. [Quantitative measurement of force and velocity of force development in the apex cardiogram. A new technic].
    Gleichmann U; Kreuzer H; Loogen F; Wilke KH
    Z Gesamte Exp Med Einschl Exp Chir; 1968; 145(3):278-88. PubMed ID: 5663893
    [No Abstract]   [Full Text] [Related]  

  • 13. [Morphological study of the carotid sphygmogram and apex cardiogram in hypertensive heart diseases].
    Bonavita E; Facchini G; Di Biase G; Tabarroni F; Spagna I; Cornia M
    Boll Soc Ital Cardiol; 1971; 16(10):637-9. PubMed ID: 5147990
    [No Abstract]   [Full Text] [Related]  

  • 14. [Diagnostic value of kinetocardiography in coronary cardiopathy].
    Calzavara G; Lusiani GB; Gambari PF; Barbui T; Castellani A
    G Clin Med; 1969 Feb; 50(2):122-31. PubMed ID: 5397331
    [No Abstract]   [Full Text] [Related]  

  • 15. [Clinical experience using a new method for quantitative registration of the apex electrocardiogram].
    Gleichmann U; Kreuzer H; Loogen F; Wilke KH
    Verh Dtsch Ges Inn Med; 1968; 74():1015-7. PubMed ID: 5714225
    [No Abstract]   [Full Text] [Related]  

  • 16. [Diagnosis of angina pectoris].
    Katzschmann R
    Z Gesamte Inn Med; 1966 Oct; 21(20):618-23. PubMed ID: 5996787
    [No Abstract]   [Full Text] [Related]  

  • 17. [Clinical analysis of a normal apex cardiogram (rate apex cardiogram)].
    Iakubovich AA; Grebenev AL
    Klin Med (Mosk); 1968 Jan; 46(1):72-8. PubMed ID: 5651399
    [No Abstract]   [Full Text] [Related]  

  • 18. Midsternal kinetocardiography with solid system recorder.
    Zoneraich S; Zoneraich O; Douglas AH
    N Y State J Med; 1968 Mar; 68(5):631-7. PubMed ID: 5238727
    [No Abstract]   [Full Text] [Related]  

  • 19. Comparability and reproducibility of apex cardiogram recorded with six different transducer systems.
    Willems JL; Denef B; Kesteloot H; De Geest H
    Br Heart J; 1979 Jun; 41(6):716-26. PubMed ID: 465246
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Apex cardiogram in the diagnosis of heart aneurysm].
    Kenedi I; Dévai I
    Ter Arkh; 1969 Sep; 41(9):77-82. PubMed ID: 5396458
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 5.