These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
7. Quantification of rectifications for the Northwestern University Flexible Sub-Ischial Vacuum Socket. Fatone S; Johnson WB; Tran L; Tucker K; Mowrer C; Caldwell R Prosthet Orthot Int; 2017 Jun; 41(3):251-257. PubMed ID: 28094689 [TBL] [Abstract][Full Text] [Related]
8. Negative pressures during swing phase in below-knee prostheses with rubber sleeve suspension. Chino N; Pearson JR; Cockrell JL; Mikishko HA; Koepke GH Arch Phys Med Rehabil; 1975 Jan; 56(1):22-6. PubMed ID: 1115589 [TBL] [Abstract][Full Text] [Related]
9. Frictional action at lower limb/prosthetic socket interface. Zhang M; Turner-Smith AR; Roberts VC; Tanner A Med Eng Phys; 1996 Apr; 18(3):207-14. PubMed ID: 8718946 [TBL] [Abstract][Full Text] [Related]
10. Stump-socket interface pressure as an aid to socket design in prostheses for trans-femoral amputees--a preliminary study. Lee VS; Solomonidis SE; Spence WD Proc Inst Mech Eng H; 1997; 211(2):167-80. PubMed ID: 9184457 [TBL] [Abstract][Full Text] [Related]
11. Relationship between socket pressure and EMG of two muscles in trans-femoral stumps during gait. Hong JH; Mun MS Prosthet Orthot Int; 2005 Apr; 29(1):59-72. PubMed ID: 16180378 [TBL] [Abstract][Full Text] [Related]
13. The ICEROSS concept: a discussion of a philosophy. Kristinsson O Prosthet Orthot Int; 1993 Apr; 17(1):49-55. PubMed ID: 8337100 [TBL] [Abstract][Full Text] [Related]
14. Interface pressures during ambulation using suction and vacuum-assisted prosthetic sockets. Beil TL; Street GM; Covey SJ J Rehabil Res Dev; 2002; 39(6):693-700. PubMed ID: 17943671 [TBL] [Abstract][Full Text] [Related]
15. An investigation on effects of amputee's physiological parameters on maximum pressure developed at the prosthetic socket interface using artificial neural network. Nayak C; Singh A; Chaudhary H; Unune DR Technol Health Care; 2017 Oct; 25(5):969-979. PubMed ID: 28854522 [TBL] [Abstract][Full Text] [Related]
16. Interface pressure profile analysis for patellar tendon-bearing socket and hydrostatic socket. Moo EK; Osman NA; Pingguan-Murphy B; Abas WA; Spence WD; Solomonidis SE Acta Bioeng Biomech; 2009; 11(4):37-43. PubMed ID: 20405814 [TBL] [Abstract][Full Text] [Related]
17. Ideas on the suspension of the below-knee prosthesis. Grevsten S Prosthet Orthot Int; 1978 Apr; 2(1):3-7. PubMed ID: 724414 [TBL] [Abstract][Full Text] [Related]
18. Assessment of amputee socket-stump-residual bone kinematics during strenuous activities using Dynamic Roentgen Stereogrammetric Analysis. Papaioannou G; Mitrogiannis C; Nianios G; Fiedler G J Biomech; 2010 Mar; 43(5):871-8. PubMed ID: 20047746 [TBL] [Abstract][Full Text] [Related]
19. Change in residual limb size over time in the NU-FlexSIV socket: A case study. Fatone S; Yohay J; Caldwell R Prosthet Orthot Int; 2018 Dec; 42(6):620-625. PubMed ID: 29775131 [TBL] [Abstract][Full Text] [Related]
20. An open socket technique for through-knee amputations in relation to skin problems of the stump: an explorative study. Otter N; Postema K; Rijken RA; van Limbeek J Clin Rehabil; 1999 Feb; 13(1):34-43. PubMed ID: 10327095 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]