These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

117 related articles for article (PubMed ID: 525283)

  • 1. A clinical study on the detection of strabismus, anisometropia or ametropia of children by simultaneous photography of the corneal and the fundus reflexes.
    Kaakinen K; Tommila V
    Acta Ophthalmol (Copenh); 1979 Aug; 57(4):600-11. PubMed ID: 525283
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A simple method for screening of children with strabismus, anisometropia or ametropia by simultaneous photography of the corneal and the fundus reflexes.
    Kaakinen K
    Acta Ophthalmol (Copenh); 1979 Apr; 57(2):161-71. PubMed ID: 452880
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Photographic screening for strabismus and high refractive errors of children aged 1-4 years.
    Kaakinen K
    Acta Ophthalmol (Copenh); 1981 Feb; 59(1):38-44. PubMed ID: 7211280
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Mass screening of children for strabismus or ametropia with two-flash photoskiascopy.
    Kaakinen K; Kaseva H; Kause ER
    Acta Ophthalmol (Copenh); 1986 Feb; 64(1):105-10. PubMed ID: 3962614
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The optics of static photographic skiascopy. Comments on a paper by K. Kaakinen: A simple method for screening of children with strabismus, anisometropia or ametropia by simultaneous photography of the corneal and the fundus reflexes.
    Howland HC
    Acta Ophthalmol (Copenh); 1980 Apr; 58(2):221-7. PubMed ID: 7395482
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Photorefraction: a useful tool to detect small angle strabismus.
    Abrahamsson M; Fabian G; Sjöstrand J
    Acta Ophthalmol (Copenh); 1986 Feb; 64(1):101-4. PubMed ID: 3962613
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Simultaneous two flash static photoskiascopy. A simple method for screening of children with strabismus or high refractive errors by simultaneous static photographic skiascopy of the horizontal and vertical meridian of both eyes and the documentation of the corneal and fundus reflexes in one photograph.
    Kaakinen K
    Acta Ophthalmol (Copenh); 1981 Jun; 59(3):378-86. PubMed ID: 7324886
    [No Abstract]   [Full Text] [Related]  

  • 8. Pediatric photoscreening for strabismus and refractive errors in a high-risk population.
    Simons BD; Siatkowski RM; Schiffman JC; Berry BE; Flynn JT
    Ophthalmology; 1999 Jun; 106(6):1073-80. PubMed ID: 10366073
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Photorefraction: A useful tool to detect refraction errors.
    Sjöstrand J; Abrahamsson M; Fabian G; Wennhall O
    Acta Ophthalmol Suppl; 1983; 157():46-52. PubMed ID: 6305097
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Vertical location of the corneal light reflex in strabismus photography.
    Hunter DG; Guyton DL
    Arch Ophthalmol; 1998 Jun; 116(6):767-71. PubMed ID: 9639445
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Photographic method for Brückner and Hirschberg testing.
    Griffin JR; McLin LN; Schor CM
    Optom Vis Sci; 1989 Jul; 66(7):474-9. PubMed ID: 2771335
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Guidelines for prescribing optical correction in children.
    Wutthiphan S
    J Med Assoc Thai; 2005 Nov; 88 Suppl 9():S163-9. PubMed ID: 16681071
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Video refraction measurement in the first year of life].
    Althaus K; Bischoff P
    Klin Monbl Augenheilkd; 1994 Sep; 205(3):133-7. PubMed ID: 7996817
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Clinical use of simultaneous photography of the corneal and the fundus reflexes].
    Wang GJ
    Zhonghua Yan Ke Za Zhi; 1988 May; 24(3):150-4. PubMed ID: 3147865
    [No Abstract]   [Full Text] [Related]  

  • 15. Screening of infants for strabismus and refractive errors with two-flash photorefraction with and without cycloplegia.
    Kaakinen K; Ranta-Kemppainen L
    Acta Ophthalmol (Copenh); 1986 Oct; 64(5):578-82. PubMed ID: 3811870
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Two-flash photorefraction in screening of amblyogenic refractive errors.
    Kaakinen KA; Kaseva HO; Teir HH
    Ophthalmology; 1987 Aug; 94(8):1036-42. PubMed ID: 3658364
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Photorefraction with a catadioptric lens. Improvement on the method of Kaakinen.
    Norcia AM; Zadnik K; Day SH
    Acta Ophthalmol (Copenh); 1986 Aug; 64(4):379-85. PubMed ID: 3776500
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Ophthalmic findings in Apert's syndrome after craniofacial surgery: twenty-nine years' experience.
    Khong JJ; Anderson P; Gray TL; Hammerton M; Selva D; David D
    Ophthalmology; 2006 Feb; 113(2):347-52. PubMed ID: 16458095
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Pre- and Postcycloplegic Refractions in Children and Adolescents.
    Zhu D; Wang Y; Yang X; Yang D; Guo K; Guo Y; Jing X; Pan CW
    PLoS One; 2016; 11(12):e0167628. PubMed ID: 27907165
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Screening of strabismus and refractive errors in children by simultaneous photography of the corneal and fundal reflexes].
    Wang GJ
    Zhonghua Yan Ke Za Zhi; 1988 Jan; 24(1):44-8. PubMed ID: 3142751
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 6.