These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
75 related articles for article (PubMed ID: 5275540)
1. [Results and problems in the long-term use of biogalvanic elements for energy supply of pacemakers]. Schaldach M Thoraxchir Vask Chir; 1970 Oct; 18(5):437-42. PubMed ID: 5275540 [No Abstract] [Full Text] [Related]
2. An aluminium silver-silverchloride biogalvanic cell. Lagergren H; Dahlgren S; Thornander H; Rao JR Ann Cardiol Angeiol (Paris); 1971; 20(4):417-9. PubMed ID: 5119743 [No Abstract] [Full Text] [Related]
3. Metal-oxygen and glucose-oxygen cells for implantable devices. Rao JR; Richter G; von Sturm F; Weidlich E; Wenzel M Biomed Eng; 1974 Mar; 9(3):98-103. PubMed ID: 4817902 [No Abstract] [Full Text] [Related]
4. [Use of galvanic elements and biological fuel cells for endogenous energy supply of heart pacemakers]. Schaldach M; Bücherl ES; Blaser R; Franke O Thoraxchir Vask Chir; 1968 Dec; 16(6):540-4. PubMed ID: 5255128 [No Abstract] [Full Text] [Related]
6. In vivo electrochemical power generation. Schaldach M; Kirsch U Trans Am Soc Artif Intern Organs; 1970; 16():184-92. PubMed ID: 5454165 [No Abstract] [Full Text] [Related]
7. Clinical experience of a biogalvanic pacemaker. Schaldach M Ann Cardiol Angeiol (Paris); 1971; 20(4):409-16. PubMed ID: 5119742 [No Abstract] [Full Text] [Related]
8. [Use of pacemakers with biogalvanic energy supply in patient with AV block third grade]. Witte J; Warnke H; Dressler L Dtsch Gesundheitsw; 1968 Jul; 23(28):1338-9. PubMed ID: 5679099 [No Abstract] [Full Text] [Related]
9. [Reduction of impulse duration for saving energy in pacemaker therapy]. Steinbach K; Joskowics G Acta Med Austriaca; 1976; 3(1):13-6. PubMed ID: 998144 [TBL] [Abstract][Full Text] [Related]
16. [Systems and results of long-term therapy with artificial pacemakers]. Schaudig A Med Klin; 1968 Dec; 63(52):2109-13. PubMed ID: 5729220 [No Abstract] [Full Text] [Related]
17. Magnetically actuated pulse width control for implantable pacemakers. Its significance for the follow-up of patients and the reduction of current drain. Chardack WM; Baken EE; Bolduc L; Giori FA; Gage AA Ann Cardiol Angeiol (Paris); 1971; 20(4):345-55. PubMed ID: 5000915 [No Abstract] [Full Text] [Related]
18. [Oscilloscopic study of the stimulus: a new technic of surveillance of implanted pacemakers]. Faivre G; Dodinot B; Petitier H; Mayer G; Heuilly MC Arch Mal Coeur Vaiss; 1970 Sep; 63(9):1209-29. PubMed ID: 4991256 [No Abstract] [Full Text] [Related]