119 related articles for article (PubMed ID: 5307293)
1. [Attachment for the 3-mirror contact lens with a variable-length indentator].
Eisner G
Albrecht Von Graefes Arch Klin Exp Ophthalmol; 1969; 178(2):183-6. PubMed ID: 5307293
[No Abstract] [Full Text] [Related]
2. [On amplified possibilities of fundoscopy with the 3 mirror contact lens by Goldmann].
Liesenhoff H
Klin Monbl Augenheilkd; 1967; 151(3):382-5. PubMed ID: 5590164
[No Abstract] [Full Text] [Related]
3. Diagnostic contact lens.
SARWAR M
Br J Ophthalmol; 1954 Oct; 38(10):626-8. PubMed ID: 13199234
[No Abstract] [Full Text] [Related]
4. Diagnostic corneal contact lenses. A kit to facilitate ophthalmoscopy.
Weimer JR
Am J Ophthalmol; 1966 Jul; 62(1):159-60. PubMed ID: 5939444
[No Abstract] [Full Text] [Related]
5. The slit lamp biomicroscope in the contact lens examination.
Gaston DC
J Ophthalmic Nurs Technol; 1984; 3(2):82-5. PubMed ID: 6559871
[No Abstract] [Full Text] [Related]
6. [A convex-concave contact lens for vitreoretinal operations with the BIOM].
Eckardt C; Wiechens B
Klin Monbl Augenheilkd; 1991 Jan; 198(1):64-5. PubMed ID: 2023380
[TBL] [Abstract][Full Text] [Related]
7. On slit-lamp microscopy.
Schmidt TA
Doc Ophthalmol; 1975 Nov; 39(1):117-53. PubMed ID: 1201695
[TBL] [Abstract][Full Text] [Related]
8. Adjustable mirror contact lens for fundus and vitreous examinations.
Tolentino FI; Rietzler X; Pomerantzeff O; Schepens CL; Freeman HM
Ann Ophthalmol; 1972 Feb; 4(2):95-8. PubMed ID: 5058397
[No Abstract] [Full Text] [Related]
9. Wide angle fundus contact lens.
Schirmer KE; Shea M
Arch Ophthalmol; 1970 Jul; 84(1):66. PubMed ID: 5423611
[No Abstract] [Full Text] [Related]
10. Faceted contact lens with a modified viewing device for fundus examination.
Schirmer KE
Arch Ophthalmol; 1965 Oct; 74(4):465-9. PubMed ID: 5838363
[No Abstract] [Full Text] [Related]
11. A self-retaining contact lens for slit-lamp examination of the fundus and for photocoagulation treatment.
Sebestyen JG
Am J Ophthalmol; 1976 May; 81(5):683-4. PubMed ID: 1275050
[TBL] [Abstract][Full Text] [Related]
12. New contact lens for peripheral fundus examination and photocoagulation.
Lee P; Pomerantzeff O; Eng D; Schepens CL
Arch Ophthalmol; 1970 Nov; 84(5):650-4. PubMed ID: 4991285
[No Abstract] [Full Text] [Related]
13. [Wide-angle contact lens based on Dudragne's principle. A very useful and little known instrument].
Bonnin P
Bull Soc Ophtalmol Fr; 1986 Apr; 86(4):465-7. PubMed ID: 3815680
[No Abstract] [Full Text] [Related]
14. Fundus holography through a wide-angle contact lens.
Rosen AN
Invest Ophthalmol; 1973 Oct; 12(10):786-8. PubMed ID: 4784284
[No Abstract] [Full Text] [Related]
15. A new high-power biconcave contact lens for observation and coagulation of the posterior segment.
Rol P
Ophthalmic Surg Lasers Imaging; 2006; 37(2):169-74. PubMed ID: 16583644
[TBL] [Abstract][Full Text] [Related]
16. New contact lens for observation and coagulation of the retina and choroid.
Rol P; Fankhauser F; Kwasniewska S
Am J Ophthalmol; 1988 May; 105(5):479-82. PubMed ID: 3369517
[TBL] [Abstract][Full Text] [Related]
17. [A new high-power biconcave contact lens for observation and coagulation tasks of the posterior segment].
Rol PO; Fankhauser F
Klin Monbl Augenheilkd; 2006 Aug; 223(8):662-7. PubMed ID: 16927222
[TBL] [Abstract][Full Text] [Related]
18. [Diagnostic contact lenses].
Etzine S
Bull Mem Soc Fr Ophtalmol; 1976; (87):120-1. PubMed ID: 1268391
[No Abstract] [Full Text] [Related]
19. [Retinography using contact lens based on Dudragne's principle in veterinary medicine].
Krouch P; Bonnin P
Bull Soc Ophtalmol Fr; 1986 Apr; 86(4):469-70. PubMed ID: 3815681
[No Abstract] [Full Text] [Related]
20. Instrument for the examination and measurement of contact lenses.
Lobel D
Am J Ophthalmol; 1986 Jul; 102(1):120-1. PubMed ID: 3728613
[No Abstract] [Full Text] [Related]
[Next] [New Search]