These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

147 related articles for article (PubMed ID: 5321845)

  • 21. Measurement of cardiac output by means of the dye dilution technique using the dynamic method of curve calibration.
    Chlebus H; Kadzielawa R; Raczyński J
    Pol Med J; 1969; 8(5):1031-41. PubMed ID: 4911161
    [No Abstract]   [Full Text] [Related]  

  • 22. [Current status of indicator dilution technics used in the diagnosis of intracardiac defects with the report of the first cases studied in the country with this technic].
    Hernández Pieretti O
    Gac Med Caracas; 1965; 73(7):335-99. PubMed ID: 5326407
    [No Abstract]   [Full Text] [Related]  

  • 23. [Wofaverdin -- an indocyanine dye for arterial and venous dilution diagnosis].
    Porstmann W; Banaschak H
    Dtsch Gesundheitsw; 1965 May; 20(20):889-93. PubMed ID: 5318453
    [No Abstract]   [Full Text] [Related]  

  • 24. [Dye dilution tests in the clinical diagnosis of congenital heart defects].
    Bender F
    Anglo Ger Med Rev; 1967 Dec; 4(1):116-8. PubMed ID: 4873154
    [No Abstract]   [Full Text] [Related]  

  • 25. [Dye-dilution curves in microcatheter examinations. Diagnosis using the dye dilution technic in the cardiologic pre-field diagnosis].
    Klein CP; Schieffer H; Bette L
    Med Welt; 1978 Mar; 29(11):423-6. PubMed ID: 349308
    [No Abstract]   [Full Text] [Related]  

  • 26. [Measurement of cardiac output using indocyanine green and its clinical application].
    Kawai C; Yamashita K; Takatsu T
    Saishin Igaku; 1968 Sep; 23(9):1955-65. PubMed ID: 4886531
    [No Abstract]   [Full Text] [Related]  

  • 27. [Determination of cardiac output using a dye without arterial puncture].
    Hensel G
    Z Kardiol; 1973 Apr; 62(4):303-14. PubMed ID: 4575756
    [No Abstract]   [Full Text] [Related]  

  • 28. [Repeated bedside determination of the heart volume. Preliminary report].
    Gurtner HP; Salzmann C; Streit W
    Schweiz Med Wochenschr; 1968 Aug; 98(33):1232-6. PubMed ID: 4878789
    [No Abstract]   [Full Text] [Related]  

  • 29. [Use of dyes in the diagnosis of congenital cardiovascular malformations with left-right and right-left shunts].
    Streian C
    Med Interna (Bucur); 1966 Oct; 18(10):1207-13. PubMed ID: 5342038
    [No Abstract]   [Full Text] [Related]  

  • 30. [Patent blue as an indicator for the registration of dye dilution technics].
    Bender F; Schmidt E; Reploh HD; Berthel R
    Z Kreislaufforsch; 1969 Mar; 58(3):294-9. PubMed ID: 4890660
    [No Abstract]   [Full Text] [Related]  

  • 31. A new calculation method for left-to-right shunts established by radiocardiography. Comparison with dye dilution techniques.
    Strangfeld D; Günther KH; Porstmann W; Buchali K
    Cardiology; 1972; 57(3):119-25. PubMed ID: 4557526
    [No Abstract]   [Full Text] [Related]  

  • 32. [Clinical application of the dye dilution technic. 2. On the diagnosis of shunting in congenital heart disease].
    Nakamura T; Katori R; Miyazawa K; Murai M; Watanabe T
    Saishin Igaku; 1965 Oct; 20(10):2819-25. PubMed ID: 5328958
    [No Abstract]   [Full Text] [Related]  

  • 33. A method for the calculation of areas under indicator-dilution curves.
    Williams JC; O'Donovan TP; Wood EH
    J Appl Physiol; 1966 Mar; 21(2):695-9. PubMed ID: 5327232
    [No Abstract]   [Full Text] [Related]  

  • 34. [On the variability of calibration curves (dynamic calibration) in indicator dilution studies].
    Juchems R
    Z Kreislaufforsch; 1966 Jul; 55(7):686-8. PubMed ID: 4868073
    [No Abstract]   [Full Text] [Related]  

  • 35. A system for on-line computer analysis of data during heart catheterization.
    Warner HR; Gardner RM; Pryor TA; Day WC; Stauffer WM
    UCLA Forum Med Sci; 1970; 10():409-18. PubMed ID: 4939443
    [No Abstract]   [Full Text] [Related]  

  • 36. [A time-saving empirical method to calculate the area under dye dilution curves for the determination of cardiac output (author's transl)].
    Schad H; Brechtelsbauer H
    Anaesthesist; 1981 May; 30(5):243-5. PubMed ID: 7018321
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Limitations of thermal dilution curves for cardiac output determinations.
    Wessel HU; Paul MH; James GW; Grahn AR
    J Appl Physiol; 1971 May; 30(5):643-52. PubMed ID: 4929471
    [No Abstract]   [Full Text] [Related]  

  • 38. A linearly responding monochromatic cuvette densitometer for indocyanine green.
    Knutsen B; Lund-Johansen P; Hatletveit E
    Scand J Clin Lab Invest; 1966; 18(6):673-8. PubMed ID: 5335274
    [No Abstract]   [Full Text] [Related]  

  • 39. [Dye dilution studies with injection of the indicator into the left heart].
    Apitz J
    Monatsschr Kinderheilkd (1902); 1965 Oct; 113(10):600-4. PubMed ID: 5326767
    [No Abstract]   [Full Text] [Related]  

  • 40. Cardiovascular monitoring by pulse dye densitometry or arterial indocyanine green dilution.
    Reekers M; Simon MJ; Boer F; Mooren RA; van Kleef JW; Dahan A; Vuyk J
    Anesth Analg; 2009 Aug; 109(2):441-6. PubMed ID: 19608815
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.