These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

65 related articles for article (PubMed ID: 5338276)

  • 1. [Further considerations on the Stewart-Hamilton method in the measurement of cardiac output in the rabbit, in various types of anesthesia].
    Berti F; Laveneziana D; Marchi P; Zocche GP
    Boll Soc Ital Biol Sper; 1964 Oct; 40(19):1143-5. PubMed ID: 5338276
    [No Abstract]   [Full Text] [Related]  

  • 2. An algorithm for the automated determination of cardiac output by the Stewart-Hamilton method.
    Francis DB; Hu KC
    IEEE Trans Biomed Eng; 1977 Sep; 24(5):482-4. PubMed ID: 330388
    [No Abstract]   [Full Text] [Related]  

  • 3. [Experimental studies on hemodynamic changes during enflurane anesthesia. 1. A study of cardiac output by thermal dilution method].
    Mori H; Ishii Y; Shioya M; Takayasu Y; Sagara N
    Masui; 1974 Oct; 23(11):1101-9. PubMed ID: 4613877
    [No Abstract]   [Full Text] [Related]  

  • 4. Stewart-Hamilton and gamma variate methods in computer analysis of dye curves.
    Kettunen R; Timisjärvi J; Kouvalainen E; Koskela M; Nuutinen L; Heikkilä J
    Scand J Clin Lab Invest; 1984 Nov; 44(7):587-94. PubMed ID: 6397844
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Thermodilution applied to the measurement of cardiac output of small laboratory animals, mainly the rat].
    Houdas Y; Ketelers JY; Houdas-Heyraud C; Lerche E
    Pathol Biol (Paris); 1969 Dec; 17(23):1069-78. PubMed ID: 4908013
    [No Abstract]   [Full Text] [Related]  

  • 6. [CONSIDERATIONS ON THE USE OF THE STEWART-HAMILTON METHOD IN THE MEASUREMENT OF CARDIAC OUTPUT IN RABBITS].
    BERTI F; ZOCCHE GP
    Boll Soc Ital Biol Sper; 1963 Oct; 39():1193-6. PubMed ID: 14119230
    [No Abstract]   [Full Text] [Related]  

  • 7. [Reliability of cardiac output measurement by means of the cold dilution technic by the automatic method of Piiper-Slama model study].
    Gethmann JW; Hellige G; Hensel I; Knoll D; Martel I
    Pflugers Arch; 1972; 332():Suppl 332:R50. PubMed ID: 4559516
    [No Abstract]   [Full Text] [Related]  

  • 8. [Computer evaluation of cardiac output by the indicator dilution method].
    Mazurkevich GS; Beliaevskiĭ OA; Dorokhin VM; Senchuk VS; Tiukavin AI
    Fiziol Zh SSSR Im I M Sechenova; 1984 Nov; 70(11):1577-81. PubMed ID: 6394365
    [No Abstract]   [Full Text] [Related]  

  • 9. Cardiac output: comparison of Stewart-Hamilton and gamma-function techniques.
    Yoder RD; Swan EA
    J Appl Physiol; 1971 Aug; 31(2):318-21. PubMed ID: 4934204
    [No Abstract]   [Full Text] [Related]  

  • 10. Cardiac output under anaesthesia.
    McDowall DG
    Ann R Coll Surg Engl; 1970 Mar; 46(3):128-9. PubMed ID: 4392766
    [No Abstract]   [Full Text] [Related]  

  • 11. Determination of cardiac output in the anaesthetized rat.
    Imms FJ; Jones MT; Neame RL
    J Physiol; 1971 May; 215(1):8P. PubMed ID: 4931519
    [No Abstract]   [Full Text] [Related]  

  • 12. Accuracy of a radiopotassium dilution (Stewart principle) method for the measurement of cardiac output.
    CONN HL
    J Appl Physiol; 1955 Mar; 7(5):542-8. PubMed ID: 14367244
    [No Abstract]   [Full Text] [Related]  

  • 13. [Measurement of cardiac output using ether dilution (author's transl)].
    Suwa K; Meguro K; Ohtake K; Yamamura H
    Kokyu To Junkan; 1980 Nov; 28(11):1277-81. PubMed ID: 7017862
    [No Abstract]   [Full Text] [Related]  

  • 14. Electrical calibration for the saline-dilution method for cardiac output.
    Smith M; Geddes LA; Hoff HE
    Cardiovasc Res Cent Bull; 1968; 6(4):142-57. PubMed ID: 4914828
    [No Abstract]   [Full Text] [Related]  

  • 15. Measurement of cardiac output by thermal dilution. II. A new computer for rapid, convenient determinations.
    Phillips CM; Davila JC; Sanmarco ME
    Med Res Eng; 1970 Sep; 9(4):25-9. PubMed ID: 4922582
    [No Abstract]   [Full Text] [Related]  

  • 16. Comparison of noninvasive cardiac output measured by use of partial carbon dioxide rebreathing or the lithium dilution method in anesthetized foals.
    Valverde A; Giguère S; Morey TE; Sanchez LC; Shih A
    Am J Vet Res; 2007 Feb; 68(2):141-7. PubMed ID: 17269878
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [The measurement of cardiac output using ether or ether and nitrous oxide (author's transl)].
    Meguro K
    Masui; 1980 Nov; 29(12):1450-62. PubMed ID: 7007681
    [No Abstract]   [Full Text] [Related]  

  • 18. Comparison of Fick and thermodilution cardiac output determinations in standing horses.
    Lépiz ML; Keegan RD; Bayly WM; Greene SA; McEwen MM
    Res Vet Sci; 2008 Oct; 85(2):307-14. PubMed ID: 18093624
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Automated cardiac output measurement by color Doppler echocardiography].
    Yagi T; Yoshida K; Hozumi T; Akasaka T; Shakudo M; Takagi T; Kaji S; Kawamoto T; Ogata Y; Kawai J; Morioka S; Yoshikawa J
    J Cardiol; 1998 Apr; 31(4):223-6. PubMed ID: 9594371
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Cardiac output measurement in pediatric anesthesia.
    Skowno JJ; Broadhead M
    Paediatr Anaesth; 2008 Nov; 18(11):1019-28. PubMed ID: 18717806
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.