These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

108 related articles for article (PubMed ID: 5344197)

  • 1. The hemodynamic consequences of the acute development of aortic valvular insufficiency in man.
    Linhart JW; Hildner FJ; Barold SS; Samet P
    J Thorac Cardiovasc Surg; 1969 Oct; 58(4):592-600. PubMed ID: 5344197
    [No Abstract]   [Full Text] [Related]  

  • 2. Haemodynamic and angiographic findings in patients with isolated aortic valvular disease before and after insertion of a Starr-Edwards aortic ball-valve prosthesis.
    Rodriguez L
    Scand J Thorac Cardiovasc Surg; 1970; ():Suppl 5:1-39. PubMed ID: 5516531
    [No Abstract]   [Full Text] [Related]  

  • 3. Hemodynamic clues to the discrepancy between the angiographic and intraoperative assessment of aortic regurgitation.
    Armstrong PW; Dinsmore RE; Harthorne JW; Sanders CA
    J Thorac Cardiovasc Surg; 1973 Aug; 66(2):265-70. PubMed ID: 4720977
    [No Abstract]   [Full Text] [Related]  

  • 4. Aortic valve replacement in patients with aortic incompetence. Preoperative parameters influencing long-term results.
    Sheiban I; Trevi GP; Casarotto D; Franco GF; Benussi P; Accardi R; Marini A; Di Bona E; Motta A; Scuro LA
    Z Kardiol; 1986; 75 Suppl 2():146-54. PubMed ID: 3727678
    [No Abstract]   [Full Text] [Related]  

  • 5. [Systolic time intervals and sound level differences between the opening and closing sounds of Starr-Edwards aortic valve prostheses (author's transl)].
    Aigner A; Müller G; Knapp E; Raas E
    Wien Klin Wochenschr; 1974 Oct; 86(19):559-61. PubMed ID: 4432513
    [No Abstract]   [Full Text] [Related]  

  • 6. Surgical treatment of combined aortic and mitral valvular disease. A clinical, haemodynamic and experimental evaluation of the standard and convexo-concave models of the Björk-Shiley tilting disc valve prosthesis.
    Aberg B
    Scand J Thorac Cardiovasc Surg Suppl; 1980; Suppl 25():1-60. PubMed ID: 6933689
    [No Abstract]   [Full Text] [Related]  

  • 7. [Hemodynamic rest and stress studies following implantation of various aortic valve prostheses].
    Horstkotte D; Haerten K; Körfer R; Spiller P; Budde T; Bircks W; Loogen F
    Z Kardiol; 1983 Aug; 72(8):429-37. PubMed ID: 6624185
    [No Abstract]   [Full Text] [Related]  

  • 8. Acute aortic regurgitation: pathophysiology and management.
    Dervan J; Goldberg S
    Cardiovasc Clin; 1986; 16(2):281-8. PubMed ID: 3742525
    [No Abstract]   [Full Text] [Related]  

  • 9. Circulatory changes following cardiac surgery.
    Fluck DC; Bescos LL; Esbenshade JH; Miller JP; Gilkes R
    Guys Hosp Rep; 1969; 118(1):105-15. PubMed ID: 5793422
    [No Abstract]   [Full Text] [Related]  

  • 10. Hemodynamic comparison of dopamine and dobutamine in the postoperative volume-loaded, pressure-loaded, and normal ventricle.
    DiSesa VJ; Brown E; Mudge GH; Collins JJ; Cohn LH
    J Thorac Cardiovasc Surg; 1982 Feb; 83(2):256-63. PubMed ID: 6977075
    [No Abstract]   [Full Text] [Related]  

  • 11. Hemodynamic state early after replacement of aortic valve with ball-valve prosthesis.
    Rastelli GC; Kirklin JW
    Surgery; 1967 Jun; 61(6):873-9. PubMed ID: 6026135
    [No Abstract]   [Full Text] [Related]  

  • 12. [Hemodynamic criteria in the surgery of mitral and aortic heart defects].
    Uglov FG; Gerasin VA; Smirnov AD
    Khirurgiia (Mosk); 1966 Jun; 42(6):89-96. PubMed ID: 5997326
    [No Abstract]   [Full Text] [Related]  

  • 13. [Natural history of chronic aortic valve. Significance of hemodynamic findings (author's transl)].
    Schwarz F; Schafft H; Federlin K; Kübler W
    Z Kardiol; 1981 Mar; 70(3):191-7. PubMed ID: 7234049
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Cardiac performance in acute aortic insufficiency].
    Romão N; Drumond Neto C; Santiago EB; Rodrigues CV; Soares RV; Lopes KW; Reis NB
    Arq Bras Cardiol; 1980 Mar; 34(3):211-6. PubMed ID: 7436779
    [No Abstract]   [Full Text] [Related]  

  • 15. Prosthetic heart valve surgery in acquired valvular heart disease.
    Attar S; Saunders E; Singleton R; McLaughlin J; Scherlis L; Cowley A
    Am Surg; 1967 Apr; 33(4):294-7. PubMed ID: 6020805
    [No Abstract]   [Full Text] [Related]  

  • 16. Ex vivo hemodynamic assessment of mechanical aortic valve gradients using a high-fidelity pressure wire.
    Michaels AD; Mester D
    Catheter Cardiovasc Interv; 2011 Apr; 77(5):726-32. PubMed ID: 21061253
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Cardiac insufficiency before and after heart surgery].
    Knebel R
    Verh Dtsch Ges Kreislaufforsch; 1968; 34():119-37. PubMed ID: 5736256
    [No Abstract]   [Full Text] [Related]  

  • 18. [An aspect of apex phonocardiograms in massive aortic insufficiency].
    Di Matteo J; Lafont H; Vacheron A; Hui Bon Hoa F; Courau F
    Arch Mal Coeur Vaiss; 1968 Aug; 61(8):1163-73. PubMed ID: 4972000
    [No Abstract]   [Full Text] [Related]  

  • 19. [Polygraphic study of cardiac dynamics and contractility after the use of valve prostheses].
    Pezzano A; Mazzini AC; Rizzi GM; Fancini P
    Atti Soc Ital Cardiol; 1970; 2():376-426. PubMed ID: 5478902
    [No Abstract]   [Full Text] [Related]  

  • 20. [Polycardiographic studies in the evaluation of failures following implantation of an artificial aortic valve as compared with direct methods].
    Tracz W; Dziatkowiak A; Moll J; Musial W; Zwoliński M
    Kardiol Pol; 1975; 18(4):373-84. PubMed ID: 1160216
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 6.