These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 5345466)

  • 1. Clear Perspex H.X. as a reference dosemeter for electron and gamma radiation.
    Berry RJ; Marshall CH
    Phys Med Biol; 1969 Oct; 14(4):585-96. PubMed ID: 5345466
    [No Abstract]   [Full Text] [Related]  

  • 2. The calibration of clear perspex HX for radiation dosimetry.
    Simmons JA; Berry RJ; Dealler JF
    Phys Med Biol; 1970 Oct; 15(4):748-9. PubMed ID: 5488151
    [No Abstract]   [Full Text] [Related]  

  • 3. COMMERCIAL 1 MM CLEAR PERSPEX AS A GAMMA-RADIATION DOSIMETER.
    DAVIDSON G; SUTTON HC
    Int J Appl Radiat Isot; 1964 Dec; 15():741-5. PubMed ID: 14248546
    [No Abstract]   [Full Text] [Related]  

  • 4. Photosensitivity of clear Perspex dosimeters.
    Whittaker B; Lowe CA
    Int J Appl Radiat Isot; 1967 Jan; 18(1):89-91. PubMed ID: 6015753
    [No Abstract]   [Full Text] [Related]  

  • 5. [Electron paramagnetic resonance in polymethyl methacrylate irradiated with Co60].
    Indovina L; Rosati A
    Ann Ist Super Sanita; 1970; 6(6):365-75. PubMed ID: 4333747
    [No Abstract]   [Full Text] [Related]  

  • 6. Relative response of dosimeters to cobalt-60 and 25 nsec pulsed electron irradiations.
    Martin JA; Jones JL; Orehotsky RS
    Health Phys; 1971 Mar; 20(3):267-75. PubMed ID: 5090002
    [No Abstract]   [Full Text] [Related]  

  • 7. An experimental examination of a general cavity theory using a solid state dosemeter.
    Chan FK; Burlin TE
    Br J Radiol; 1970 Jan; 43(505):54-61. PubMed ID: 5411568
    [No Abstract]   [Full Text] [Related]  

  • 8. Reference Perspex radiation dosemeter.
    Berry RJ; Orton CG
    Phys Med Biol; 1966 Jul; 11(3):475-6. PubMed ID: 5926691
    [No Abstract]   [Full Text] [Related]  

  • 9. Polarization induced by radiation in perspex.
    VANHUYSE VJ; VANPRAET GJ; VAN LANDUYT JF
    Nature; 1961 Aug; 191():595-6. PubMed ID: 13780163
    [No Abstract]   [Full Text] [Related]  

  • 10. Optically stimulated luminescent glass optical fibre dosemeter.
    Huston AL; Justus BL; Falkenstein PL; Miller RW; Ning H; Altemus R
    Radiat Prot Dosimetry; 2002; 101(1-4):23-6. PubMed ID: 12382700
    [TBL] [Abstract][Full Text] [Related]  

  • 11. ENERGY DISTRIBUTION OF ELECTRONS EJECTED FROM BONE AND LUCITE BY 150-300 KVP X-RAYS.
    MATSUZAWA H; HOSHINO K; INADA T; KAWASHIMA K
    Br J Radiol; 1965 Feb; 38():131-42. PubMed ID: 14254055
    [No Abstract]   [Full Text] [Related]  

  • 12. The effect of spectrophotometry error on the accuracy of the perspex H.X. megarad dosemeter.
    Crookall JO; Marshall CH
    Phys Med Biol; 1970 Apr; 15(2):319-24. PubMed ID: 5484874
    [No Abstract]   [Full Text] [Related]  

  • 13. Energy dependence of LiF and CaF2 thermoluminescent dosimeters for high energy electrons.
    Nakajima T; Hiraoka T; Habu T
    Health Phys; 1968 Mar; 14(3):266-7. PubMed ID: 5637399
    [No Abstract]   [Full Text] [Related]  

  • 14. [The effect of 180-Kv x-rays, cobalt-60-gamma rays and 17 MeV rapid electrons on lung tissue].
    Holsten DR; Stender HS
    Strahlentherapie; 1966 May; 130(1):34-42. PubMed ID: 5992445
    [No Abstract]   [Full Text] [Related]  

  • 15. Dose response of commercially available optically stimulated luminescent detector, Al2O3:C for megavoltage photons and electrons.
    Kim DW; Chung WK; Shin DO; Yoon M; Hwang UJ; Rah JE; Jeong H; Lee SY; Shin D; Lee SB; Park SY
    Radiat Prot Dosimetry; 2012 Apr; 149(2):101-8. PubMed ID: 21636557
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Measurement of dose distributions with red Perspex.
    Marshall CH; Orton CG
    Phys Med Biol; 1966 Oct; 11(4):563-8. PubMed ID: 5969857
    [No Abstract]   [Full Text] [Related]  

  • 17. An ionization chamber for therapy-level dosimetry of electron beams.
    Morris WT; Owen B
    Phys Med Biol; 1975 Sep; 20(3):718-27. PubMed ID: 810816
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Red Perspex dosimetry.
    Orton CG
    Phys Med Biol; 1966 Oct; 11(4):551-62. PubMed ID: 5969856
    [No Abstract]   [Full Text] [Related]  

  • 19. The physical measurements of electron beams from 6 to 18 Mev: absorbed dose and energy calibration.
    Almond PR
    Phys Med Biol; 1967 Jan; 12(1):13-24. PubMed ID: 6030628
    [No Abstract]   [Full Text] [Related]  

  • 20. [Influence of a metal strip on distribution of dose in Plexiglas irradiated by high energy electrons].
    Dutreix J; Bernard M
    Biophysik; 1968 May; 4(4):302-10. PubMed ID: 4969637
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 7.