These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

101 related articles for article (PubMed ID: 534566)

  • 1. A micromethod for the emergency estimation of plasma paracetamol concentration using high performance liquid chromatography.
    Buchanan T; Adriaenssens P; Stewart MJ
    Clin Chim Acta; 1979 Dec; 99(2):161-5. PubMed ID: 534566
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A simple microanalytical technique for the determination of paracetamol and its main metabolites in blood spots.
    Oliveira EJ; Watson DG; Morton NS
    J Pharm Biomed Anal; 2002 Jul; 29(5):803-9. PubMed ID: 12093512
    [TBL] [Abstract][Full Text] [Related]  

  • 3. High-performance liquid chromatographic method for the determination of trace amounts of acetaminophen in plasma.
    Korduba CA; Petruzzi RF
    J Pharm Sci; 1984 Jan; 73(1):117-9. PubMed ID: 6694066
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Determination of acetaminophen concentrations in serum by high-pressure liquid chromatography.
    Horvitz RA; Jatlow PI
    Clin Chem; 1977 Sep; 23(9):1596-8. PubMed ID: 890901
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The estimation of paracetamol and its major metabolites in both plasma and urine by a single high-performance liquid chromatography assay.
    Lau GS; Critchley JA
    J Pharm Biomed Anal; 1994 Dec; 12(12):1563-72. PubMed ID: 7696381
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Validated HPLC-UV method for determination of naproxen in human plasma with proven selectivity against ibuprofen and paracetamol.
    Filist M; Szlaska I; Kaza M; Pawiński T
    Biomed Chromatogr; 2016 Jun; 30(6):953-61. PubMed ID: 26458096
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Determination of serum acetaminophen in emergency toxicology: evaluation of newer methods: Abbott TDx and second derivative ultraviolet spectrophotometry.
    Edinboro LE; Jackson GF; Jortani SA; Poklis A
    J Toxicol Clin Toxicol; 1991; 29(2):241-55. PubMed ID: 2051511
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Rapid micro-method for the measurement of paracetamol in blood plasma or serum using gas-liquid chromatography with flame-ionisation detection.
    Huggett A; Andrews P; Flanagan RJ
    J Chromatogr; 1981 Apr; 209(1):67-76. PubMed ID: 7228941
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Determination of paracetamol (acetaminophen) in blood and plasma using high performance liquid chromatography with dual electrode coulometric quantification in the redox mode.
    Whelpton R; Fernandes K; Wilkinson KA; Goldhill DR
    Biomed Chromatogr; 1993; 7(2):90-3. PubMed ID: 8485381
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Simultaneous determination of caffeine, paracetamol, and ibuprofen in pharmaceutical formulations by high-performance liquid chromatography with UV detection and by capillary electrophoresis with conductivity detection.
    Cunha RR; Chaves SC; Ribeiro MM; Torres LM; Muñoz RA; Dos Santos WT; Richter EM
    J Sep Sci; 2015 May; 38(10):1657-62. PubMed ID: 25773878
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Determination of paracetamol and its four major metabolites in mouse plasma by reversed-phase ion-pair high-performance liquid chromatography.
    Esteban A; Graells M; Satorre J; Pérez-Mateo M
    J Chromatogr; 1992 Jan; 573(1):121-6. PubMed ID: 1564089
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Acetaminophen in serum and plasma estimated by high-pressure liquid chromatography: a micro-scale method.
    Blair D; Rumack BH
    Clin Chem; 1977; 23(4):743-5. PubMed ID: 844171
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Inappropriate methods for the emergency determination of plasma paracetamol.
    Stewart MJ; Adriaenssens PI; Jarvie DR; Prescott LF
    Ann Clin Biochem; 1979 Mar; 16(2):89-95. PubMed ID: 37799
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Simultaneous measurements of acetaminophen and salicylate in plasma by liquid chromatography.
    Miceli JN; Aravind MK; Cohen SN; Done AK
    Clin Chem; 1979 Jun; 25(6):1002-4. PubMed ID: 445799
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Simplified gas chromatographic assay for paracetamol.
    Stewart MJ; Willis RG
    Ann Clin Biochem; 1975 Jan; 12(1):4-8. PubMed ID: 15637930
    [TBL] [Abstract][Full Text] [Related]  

  • 16. High performance liquid chromatographic determination of paracetamol in human serum.
    Hannothiaux MH; Houdret N; Lhermitte M; Izydorczak J; Roussel P
    Ann Biol Clin (Paris); 1986; 44(2):139-41. PubMed ID: 3752629
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Simultaneous determination of eperisone hydrochloride and paracetamol in mouse plasma by high performance liquid chromatography-photodiode array detector.
    Locatelli M; Cifelli R; Di Legge C; Barbacane RC; Costa N; Fresta M; Celia C; Capolupo C; Di Marzio L
    J Chromatogr A; 2015 Apr; 1388():79-86. PubMed ID: 25704771
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Creatinine. XIII. Micro high-performance liquid chromatographic assay of creatinine in biological fluids using fixed- or variable-wavelength UV detector.
    Chiou WL; Pu FS; Prueksaritanont T
    J Chromatogr; 1983 Oct; 277():436-8. PubMed ID: 6643635
    [No Abstract]   [Full Text] [Related]  

  • 19. Liquid-chromatographic determination of acetaminophen in serum.
    Fletterick CG; Grove TH; Hohnadel DC
    Clin Chem; 1979 Mar; 25(3):409-12. PubMed ID: 262181
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A review of methods for plasma paracetamol estimation.
    Wiener K
    Ann Clin Biochem; 1978 Jul; 15(4):187-96. PubMed ID: 358906
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 6.