These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
113 related articles for article (PubMed ID: 534700)
21. Fetal heart rate variability changes and fetal behavioural cycles during labour. Spencer JA; Johnson P Br J Obstet Gynaecol; 1986 Apr; 93(4):314-21. PubMed ID: 3964606 [TBL] [Abstract][Full Text] [Related]
22. Transcutaneous PO2 and cardiovascular observations in the sheep fetus following the reduction of uterine blood flow. Künzel W; Kastendieck E; Kurz CS; Paulik R J Perinat Med; 1980; 8(2):85-92. PubMed ID: 7400920 [TBL] [Abstract][Full Text] [Related]
23. [Continuous transcutaneous oxygen measurement in the fetus--clinical study on the value of the procedure in the ejection period of labor]. Bellée H; Schönjahn V Zentralbl Gynakol; 1983; 105(19):1257-64. PubMed ID: 6650011 [TBL] [Abstract][Full Text] [Related]
24. Distribution of observed patterns in fetal transcutaneous oxygen tension. Rooth G; Fall O; Huch A; Huch R Am J Obstet Gynecol; 1981 Jul; 140(6):693-8. PubMed ID: 7258243 [TBL] [Abstract][Full Text] [Related]
25. Catecholamines in arterial and venous umbilical blood: placental extraction, correlation with fetal hypoxia, and transcutaneous partial oxygen tension. Paulick R; Kastendieck E; Wernze H J Perinat Med; 1985; 13(1):31-42. PubMed ID: 4009382 [TBL] [Abstract][Full Text] [Related]
26. [Reference values range of the fetal oxygen saturation and its dispersal during labor without cardiotocographic evidence for fetal distress]. Nikolov A; Dimitrov A; Vakrilova L; Iarŭkova N; Tsankova M; Krŭsteva K Akush Ginekol (Sofiia); 2005; 44(1):24-31. PubMed ID: 15853008 [TBL] [Abstract][Full Text] [Related]
27. [Fetal PO2 and FHR]. Joelsson I Lakartidningen; 1977 Jul; 74(29-30):2571-2. PubMed ID: 895259 [No Abstract] [Full Text] [Related]
28. Measurement of transcutaneous pCO2 and pO2 in the fetus during labor. Schmidt S; Langner K; Dudenhausen JW; Saling E Arch Gynecol; 1985; 236(3):145-51. PubMed ID: 3925898 [TBL] [Abstract][Full Text] [Related]
29. Transcutaneous oxygen monitoring from the fetus during labor: a study of the TcPO2 levels and comparison of two electrode application techniques. Löfgren O Biotelem Patient Monit; 1982; 9(3):166-74. PubMed ID: 7159702 [TBL] [Abstract][Full Text] [Related]
30. [Physiologic basis for fetal heart rate analysis during labour]. Doret M; Constans A; Gaucherand P J Gynecol Obstet Biol Reprod (Paris); 2010 Jun; 39(4):276-83. PubMed ID: 20193988 [TBL] [Abstract][Full Text] [Related]
31. Human fetal oxygenation following paracervical block. Baxi LV; Petrie RH; James LS Am J Obstet Gynecol; 1979 Dec; 135(8):1109-12. PubMed ID: 517595 [TBL] [Abstract][Full Text] [Related]
33. Intrapartum fetal monitoring in preterm deliveries: prospective study. Westgren M; Holmquist P; Svenningsen NW; Ingemarsson I Obstet Gynecol; 1982 Jul; 60(1):99-106. PubMed ID: 7088457 [TBL] [Abstract][Full Text] [Related]
34. A comparison of transcutaneous oxygen (tcPO2) monitoring and conventional techniques for detecting hypoxemia and hyperoxemia. Long JG; Philip AG; Lucey JF Birth Defects Orig Artic Ser; 1979; 15(4):347-53. PubMed ID: 534715 [No Abstract] [Full Text] [Related]
35. Fetal plasma catecholamine concentrations and fetal heart-rate variability during first stage of labour. Bistoletti P; Lagercrantz H; Lunell NO Br J Obstet Gynaecol; 1983 Jan; 90(1):11-5. PubMed ID: 6821663 [TBL] [Abstract][Full Text] [Related]
36. Changes in relative local perfusion and continuous transcutaneous oxygen tension in human fetuses during uterine contractions. Fall O; Johnsson M; Nilsson BA; Rooth G Birth Defects Orig Artic Ser; 1979; 15(4):259-62. PubMed ID: 534704 [No Abstract] [Full Text] [Related]
37. Comparison of continuous transcutaneous Po2 measurement with intermittent arterial Po2 determinations in fetal lambs. Mueller-Heubach E; Caritis SN; Edelstone DI; Huch R; Huch A Obstet Gynecol; 1981 Feb; 57(2):248-52. PubMed ID: 7465132 [TBL] [Abstract][Full Text] [Related]
38. Preliminary experience with intrapartum fetal pulse oximetry in humans. Dildy GA; Clark SL; Loucks CA Obstet Gynecol; 1993 Apr; 81(4):630-5. PubMed ID: 8459982 [TBL] [Abstract][Full Text] [Related]