These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
81 related articles for article (PubMed ID: 534711)
1. Correlation of PaO2/tcPO2 in relation to the difference of body temperature and temperature of the toe (delta T). Stechele U; Emmrich P Birth Defects Orig Artic Ser; 1979; 15(4):315-22. PubMed ID: 534711 [No Abstract] [Full Text] [Related]
3. Investigation of transcutaneous O2--CO2 sensors and their application on human adults and newborns. Beran AV; Huxtable RF; Black KS; Shigezawa GY; Yeung HN Birth Defects Orig Artic Ser; 1979; 15(4):421-30. PubMed ID: 534726 [No Abstract] [Full Text] [Related]
4. Interpretation of the tcPO2 curve in adult patients in an intensive care unit. Rooth G; Hedstrand U; Ogren C Birth Defects Orig Artic Ser; 1979; 15(4):557-71. PubMed ID: 534740 [TBL] [Abstract][Full Text] [Related]
5. [Postoperative managements following open heart surgery with special reference to blood gas analysis]. Sari A Masui; 1971 Mar; 20(3):209-17. PubMed ID: 5102905 [No Abstract] [Full Text] [Related]
6. [Transcutaneous oxygen and carbon dioxide measurement in pediatric intensive care patients]. Paky F; Helms P; Cheriyan G Monatsschr Kinderheilkd; 1985 Dec; 133(12):879-81. PubMed ID: 3937053 [TBL] [Abstract][Full Text] [Related]
7. [Development and application of blood gas monitoring technology]. Hagihara B Rinsho Byori; 1984 Oct; 32(10):1065-75. PubMed ID: 6441038 [No Abstract] [Full Text] [Related]
8. Comparison of the transcutaneous oxygen and carbon dioxide tension in different electrode locations during general anaesthesia. Nishiyama T; Nakamura S; Yamashita K Eur J Anaesthesiol; 2006 Dec; 23(12):1049-54. PubMed ID: 16824244 [TBL] [Abstract][Full Text] [Related]
9. [Transcutaneous electrodes for blood gas determination]. Hagihara B Iyodenshi To Seitai Kogaku; 1983 Dec; 21(7):524-30. PubMed ID: 6431156 [No Abstract] [Full Text] [Related]
10. The effect of temperature correction of blood gas values on the accuracy of end-tidal carbon dioxide monitoring in children after cardiac surgery. Suominen PK; Stayer S; Wang W; Chang AC ASAIO J; 2007; 53(6):670-4. PubMed ID: 18043144 [TBL] [Abstract][Full Text] [Related]
11. [Value of delta PO2 (difference between PaO2-tcPO2) as a circulation saving measure in hypovolemic shock]. Cloup M; Chassevent J; Prat JJ; Chlabovitch E; Cloup I Agressologie; 1980; 21(B):63-9. PubMed ID: 7235145 [No Abstract] [Full Text] [Related]