These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
194 related articles for article (PubMed ID: 5353903)
1. Electrodes for the measurement of oxygen and carbon dioxide tensions. Smith AC; Hahn CE Br J Anaesth; 1969 Sep; 41(9):731-41. PubMed ID: 5353903 [No Abstract] [Full Text] [Related]
2. Single electrochemical sensor for transcutaneous measurement of PO2 and PCO2. Parker D; Delpy DT; Reynolds EO Birth Defects Orig Artic Ser; 1979; 15(4):109-16. PubMed ID: 534689 [No Abstract] [Full Text] [Related]
3. Some problems associated with measurement of physiological blood gases. Dowd J; Jenkins LC Can Anaesth Soc J; 1973 Mar; 20(2):129-40. PubMed ID: 4689259 [No Abstract] [Full Text] [Related]
4. Normal arterial blood pH, oxygen, and carbon dioxide tensions in unanesthetized dogs. Feigl EO; D'Alecy LG J Appl Physiol; 1972 Jan; 32(1):152-3. PubMed ID: 5007010 [No Abstract] [Full Text] [Related]
5. A review of blood pH and blood-gas analysis. Beetham R Ann Clin Biochem; 1982 Jul; 19 (Pt 4)():198-213. PubMed ID: 6812483 [No Abstract] [Full Text] [Related]
6. Determination of blood-gases utilizing specially designed electrodes for PCO2, PO2, PO2 and pH. Bradley AF Biomed Sci Instrum; 1967; 3():181-8. PubMed ID: 5582603 [No Abstract] [Full Text] [Related]
7. [Intravascular electrodes for blood gas monitoring]. Hagihara B Iyodenshi To Seitai Kogaku; 1983 Dec; 21(7):517-23. PubMed ID: 6431155 [No Abstract] [Full Text] [Related]
9. [New electrode method for the measurement of oxygen and carbon dioxide contents in the blood]. Ota M Masui; 1970 Jul; 19(7):762-71. PubMed ID: 5465317 [No Abstract] [Full Text] [Related]
10. A new electrode system for continuous measurement of PH, PCO2, PO2, and temperature on flowing blood. Buzza EE; Leonard JE; Watanabe H; Carlsen EN J Assoc Adv Med Instrum; 1970; 4(4):136-44. PubMed ID: 5520703 [No Abstract] [Full Text] [Related]
11. Blood gas physiology. Pizzullo L Biomed Instrum Technol; 1997; 31(3):290-4. PubMed ID: 9181249 [No Abstract] [Full Text] [Related]
12. A comparative study of the performance of five commercial blood-gas and pH electrode analysers. Hill DW; Tilsley C Br J Anaesth; 1973 Jul; 45(7):647-54. PubMed ID: 4730157 [No Abstract] [Full Text] [Related]
13. Reliability of blood PCO2 measurements by the CO2-electrode, the whole-blood CCO2-pH method and the Astrup method. Bärtschi F; Held DR; Haab P Respir Physiol; 1970 Jul; 10(1):121-31. PubMed ID: 5430144 [No Abstract] [Full Text] [Related]
14. Accuracy of oxygen and carbon dioxide electrodes. Flenley DC; Millar JS; Rees HA Br Med J; 1967 May; 2(5548):349-52. PubMed ID: 6023132 [No Abstract] [Full Text] [Related]
15. Continuous measurement of Po2, Pco2 and pH in blood. Henningsen P Scand J Clin Lab Invest; 1968; 22(1):33-6. PubMed ID: 5706645 [No Abstract] [Full Text] [Related]
16. Techniques for measuring the partial pressures of gases in the blood. Part I--in vitro measurements. Hahn CE J Phys E; 1980 May; 13(5):470-82. PubMed ID: 6768877 [No Abstract] [Full Text] [Related]
17. Techniques for measuring the partial pressures of gases in the blood. Part II- in vivo measurements. Hahn CE J Phys E; 1981 Jul; 14(7):783-97. PubMed ID: 6787191 [No Abstract] [Full Text] [Related]
18. Industrial design of a universal transcutaneous blood gas measuring system for clinical use according to Huch-Lübbers. Frankenberger H; Neuhaeusser RE; Ullrich GJ Birth Defects Orig Artic Ser; 1979; 15(4):45-55. PubMed ID: 534728 [No Abstract] [Full Text] [Related]