These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

82 related articles for article (PubMed ID: 5369269)

  • 41. Properties of the product of partial photodissociation of carbon monoxide hemoglobin.
    Antonini E; Anderson NM; Brunori M
    J Biol Chem; 1972 Jan; 247(1):319-21. PubMed ID: 5019948
    [No Abstract]   [Full Text] [Related]  

  • 42. A new spectrophotometric method for the determination of carbon monoxide in the blood.
    HARPER PV
    J Lab Clin Med; 1952 Oct; 40(4):634-40. PubMed ID: 12990888
    [No Abstract]   [Full Text] [Related]  

  • 43. Spectrophotometric measurement of carboxyhaemoglobin. An evaluation of the method of Commins and Lawther.
    Lily RE; Cole PV; Hawkins LH
    Br J Ind Med; 1972 Oct; 29(4):454-7. PubMed ID: 4636665
    [No Abstract]   [Full Text] [Related]  

  • 44. FETAL HEMOGLOBIN; THE INFLUENCE OF CARBON MONOXIDE WHEN ESTIMATING HB-F AS ALKALI-RESISTANT HEMOGLOBIN.
    KRISTOFFERSEN K
    Scand J Clin Lab Invest; 1965; 17():151-61. PubMed ID: 14285922
    [No Abstract]   [Full Text] [Related]  

  • 45. [Carbon monoxide determination in blood with spectrophotometer].
    SCHWERD W
    Arch Toxikol; 1955; 15(4-5):288-90. PubMed ID: 13249588
    [No Abstract]   [Full Text] [Related]  

  • 46. The effect of carbon monoxide on the visual evoked response in man and the spontaneous electroencephalogram.
    Hosko MJ
    Arch Environ Health; 1970 Aug; 21(2):174-80. PubMed ID: 5430004
    [No Abstract]   [Full Text] [Related]  

  • 47. [Quantitative determination of carbon monoxide in blood].
    SCHWERD W
    Munch Med Wochenschr; 1954 Sep; 96(38):1098-9. PubMed ID: 13223683
    [No Abstract]   [Full Text] [Related]  

  • 48. [Relationship between carbon monoxide exhalation in the breath and occupational exposure].
    Ciuhandu G; Diaconovici M; Kiss L; Rusu V
    Zentralbl Arbeitsmed; 1968 Jun; 18(6):172-6. PubMed ID: 5719751
    [No Abstract]   [Full Text] [Related]  

  • 49. Experimental human exposure to methylene chloride.
    Stewart RD; Fisher TN; Hosko MJ; Peterson JE; Baretta ED; Dodd HC
    Arch Environ Health; 1972 Nov; 25(5):342-8. PubMed ID: 4651547
    [No Abstract]   [Full Text] [Related]  

  • 50. Carboxyhaemoglobin levels in blast furnace workers.
    Butt J; Davies GM; Jones JG; Sinclair A
    Ann Occup Hyg; 1974 Aug; 17(1):57-63. PubMed ID: 4451316
    [No Abstract]   [Full Text] [Related]  

  • 51. Artefact due to traces of detergent on laboratory glassware affecting carboxyhaemoglobin measurement.
    Wald NJ; Fenton J
    Clin Chim Acta; 1972 Jun; 39(1):266-8. PubMed ID: 5038759
    [No Abstract]   [Full Text] [Related]  

  • 52. Carbon monoxide and avian embryogenesis.
    Baker FD; Tumasonis CF
    Arch Environ Health; 1972 Jan; 24(1):53-61. PubMed ID: 5009632
    [No Abstract]   [Full Text] [Related]  

  • 53. On the equilibration of carbon monoxide between human maternal and fetal circulation in vivo.
    GEMZELL CA; ROBBE H; STROM G
    Scand J Clin Lab Invest; 1958; 10(4):372-8. PubMed ID: 13615241
    [No Abstract]   [Full Text] [Related]  

  • 54. Determination of the carboxyhaemoglobin saturation of blood by spectrophotometric analysis.
    Beeckmans JM
    Br J Ind Med; 1967 Jan; 24(1):71-2. PubMed ID: 6017142
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Effects on experimental animals of long-term inhalation exposure to carbon monoxide.
    Jones RA; Strickland JA; Stunkard JA; Siegel J
    Toxicol Appl Pharmacol; 1971 May; 19(1):46-53. PubMed ID: 4998901
    [No Abstract]   [Full Text] [Related]  

  • 56. [Effect of time of preservation of blood samples on the result of spectrophotometric determination of carbon oxide].
    SCHWERD W; SCHWEMMER G
    Arch Toxikol; 1957; 16(6):393-400. PubMed ID: 13522213
    [No Abstract]   [Full Text] [Related]  

  • 57. [A new method for the determination of carbon monoxide in the blood; application in the study of normal and pathologic levels of carbon monoxide in the blood].
    FABRE R; TRUHAUT R; BERROD F
    Ann Pharm Fr; 1951 Nov; 9(11):625-38. PubMed ID: 14915284
    [No Abstract]   [Full Text] [Related]  

  • 58. [Occupational exposure to carbon monoxide in welders in the metal industry].
    Bauer S; Sofronievska Z; Orusev T
    God Zb Med Fak Skopje; 1977; 23():241-4. PubMed ID: 614985
    [No Abstract]   [Full Text] [Related]  

  • 59. A simplified method for estimating carbon monoxide in blood with the volumetric Van Slyke apparatus.
    NICHOLAS JW
    J Clin Pathol; 1951 Nov; 4(4):439-44. PubMed ID: 14897922
    [No Abstract]   [Full Text] [Related]  

  • 60. [The determination of carbon monoxide in blood by means of a non-dispersive infrared differential absorption technique].
    Krüsmann K; Schröder H; Schröder J
    Arch Toxikol; 1971; 27(2):99-105. PubMed ID: 5579121
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.