BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

73 related articles for article (PubMed ID: 5406598)

  • 1. [Wainwright-Hammond compression plate for osteotomy. Indications and results].
    Bachiocco R; Savini R
    Chir Organi Mov; 1969; 58(3):223-37. PubMed ID: 5406598
    [No Abstract]   [Full Text] [Related]  

  • 2. [AOI compression plate for intertrochantic osteotomy of the femur].
    Yamada K; Suzuki K; Kobayashi A; Takarazumi Y; Okuyama S
    Shujutsu; 1971 Dec; 25(12):1431-40. PubMed ID: 5146377
    [No Abstract]   [Full Text] [Related]  

  • 3. [Compression plate for treatment of fracture of the long bone and intertrochanteric osteotomy of the femur].
    Miyagi S; Inoue H; Ikari T; Miyagi K
    Shujutsu; 1970 Jul; 24(7):818-30. PubMed ID: 5448425
    [No Abstract]   [Full Text] [Related]  

  • 4. [Correction of post-traumatic malpositions of the femur].
    Kroedel A
    Unfallchirurg; 1985 Oct; 88(10):432-6. PubMed ID: 4071068
    [No Abstract]   [Full Text] [Related]  

  • 5. [Clinical application of the AOI compression plate--with special reference to the double-angled hip plate].
    Yamada K; Suzuki K; Hozumi Y; Kobayashi A; Torigata Y
    Seikei Geka; 1971 Mar; 22(3):188-96. PubMed ID: 5102566
    [No Abstract]   [Full Text] [Related]  

  • 6. [Surgical technic for shortening of the femur in unequal length of the extremities].
    Cech O
    Acta Chir Orthop Traumatol Cech; 1969 Oct; 36(5):275-8. PubMed ID: 5364364
    [No Abstract]   [Full Text] [Related]  

  • 7. [Intertrochanteric extension and flexion osteotomy for traumatic femoral head defects (author's transl)].
    Schneider R
    Unfallheilkunde; 1977 May; 80(5):177-81. PubMed ID: 867593
    [No Abstract]   [Full Text] [Related]  

  • 8. Comparison analysis of the operative treatment results of the femoral neck fractures using side-plate and compression screw and cannulated AO screws.
    Stiasny J; Dragan S; Kulej M; Martynkiewicz J; Płochowski J; Dragan SŁ
    Ortop Traumatol Rehabil; 2008; 10(4):350-61. PubMed ID: 18779768
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Treatment of distal femoral fractures with minimally invasive percutaneous buttress plate osteosynthesis of femoral condyle].
    Sun DS; Guan TJ; Wei CY
    Zhongguo Gu Shang; 2008 Nov; 21(11):862-3. PubMed ID: 19143256
    [No Abstract]   [Full Text] [Related]  

  • 10. Femoral overgrowth following plate fixation of the fractured femur in children.
    Sulaiman AR; Joehaimy J; Iskandar MA; Anwar Hau M; Ezane AM; Faisham WI
    Singapore Med J; 2006 Aug; 47(8):684-7. PubMed ID: 16865208
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Stress analyses after femoral shaft osteotomy fixed by various plates with different rigidities in simulation test.
    Xu XX; Zhang X; Liu JG; Wang JB; Shi DG; Liu SX
    Chin Med J (Engl); 1993 Feb; 106(2):127-31. PubMed ID: 8504696
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Biomechanical comparison of two side plate fixation techniques in an unstable intertrochanteric osteotomy model: Sliding Hip Screw and Percutaneous Compression Plate.
    Krischak GD; Augat P; Beck A; Arand M; Baier B; Blakytny R; Gebhard F; Claes L
    Clin Biomech (Bristol, Avon); 2007 Dec; 22(10):1112-8. PubMed ID: 17900766
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Correction of post-traumatic malposition of the femur].
    Wawro W; Korsikowski GR; Otto W; Wermann H; Wöllenweber HD
    Beitr Orthop Traumatol; 1987 Mar; 34(3):154-61. PubMed ID: 3619867
    [No Abstract]   [Full Text] [Related]  

  • 14. [Screw-plate with translation for high femoral osteotomy (author's transl)].
    Roy-Camille R; Lelièvre JF; Saillant G
    Nouv Presse Med; 1978 May; 7(20):1741-2. PubMed ID: 673718
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Modified tubular nail for fixation of fractures and osteotomies of the trochanteric region and supracondylar fractures of the femur].
    Arct WA; Oblonczek G
    Chir Narzadow Ruchu Ortop Pol; 1970; 35(1):113-6. PubMed ID: 5439056
    [No Abstract]   [Full Text] [Related]  

  • 16. Trochanteric fractures of the femur treated by the vitallium McLaughlin nail and plate.
    Wong PC
    Singapore Med J; 1969 Sep; 10(3):170-3. PubMed ID: 5366141
    [No Abstract]   [Full Text] [Related]  

  • 17. Role of valgus osteotomy and fixation by double-angle blade plate in neglected displaced intracapsular fracture of neck of femur in younger patients.
    Sringari T; Jain UK; Sharma VD
    Injury; 2005 May; 36(5):630-4. PubMed ID: 15826623
    [TBL] [Abstract][Full Text] [Related]  

  • 18. One-stage lengthening and derotational osteotomy of the femur stabilised with a gamma nail.
    van Doorn R; Leemans R; Stapert JW
    Eur J Surg; 1999 Dec; 165(12):1142-6. PubMed ID: 10636547
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Treatment of fractures with the compression plate and its problems].
    Abematsu N; Miyasaka T; Karasawa Y
    Seikei Geka; 1971 Mar; 22(3):178-87. PubMed ID: 5102565
    [No Abstract]   [Full Text] [Related]  

  • 20. A new intramedullary fixation device for the distal third of the femur.
    Zickel RE; Fietti VG; Lawsing JF; Cochran GV
    Clin Orthop Relat Res; 1977 Jun; (125):185-91. PubMed ID: 880764
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.