These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
7. [Reoperation for a Starr-Edwards ball valve prosthesis implanted in mitral position 31 years ago]. Goshima M; Shiono M; Yamamoto T; Inoue T; Hata M; Sezai A; Niino T; Nakamura T; Ye Z; Negishi N; Sezai Y Kyobu Geka; 2003 Jul; 56(7):535-40. PubMed ID: 12854458 [TBL] [Abstract][Full Text] [Related]
8. [Artificial valve failure at a period of 13 years after mitral valve replacement:a comment of mechanism of late Starr-Edwards ball valve failure]. Sato T; Tatsumi A; Oseko T; Fujio A; Masuda H Rinsho Kyobu Geka; 1982; 2(1):117-21. PubMed ID: 7156711 [No Abstract] [Full Text] [Related]
9. Ball fracture with the 6120-model Starr-Edwards mitral valve prosthesis occurring late after implantation. Mazzucco A; Luciani GB; Pessotto R; Piccin C; Faggian G; Chiominto B J Heart Valve Dis; 1993 Mar; 2(2):245-7. PubMed ID: 8261163 [TBL] [Abstract][Full Text] [Related]
10. Respiratory distress in man with prosthetic valve. Patel A; Goldman DS Hosp Pract (Off Ed); 1987 May; 22(5):256-9. PubMed ID: 3106379 [No Abstract] [Full Text] [Related]
11. Extended (31 years) durability of a Starr-Edwards prosthesis in mitral position. Tarzia V; Bottio T; Testolin L; Gerosa G Interact Cardiovasc Thorac Surg; 2007 Aug; 6(4):570-1. PubMed ID: 17669941 [TBL] [Abstract][Full Text] [Related]
12. Reoperation for a patient 25 years after a Starr-Edwards ball mitral valve was installed. Ye Z; Shiono M; Sezai A; Inoue T; Hata M; Niino T; Goshima M; Nakamura T; Negishi N; Sezai Y Ann Thorac Cardiovasc Surg; 2002 Oct; 8(5):311-5. PubMed ID: 12472416 [TBL] [Abstract][Full Text] [Related]
13. [Auscultation and phonomechanocardiography in patients with Starr-Edwards mitral prosthesis]. Calviño GE; Ferreiros ER; Cossio PR Prensa Med Argent; 1970 Oct; 57(31):1499-503. PubMed ID: 5485490 [No Abstract] [Full Text] [Related]
14. Late postoperative clinical and hemodynamic assessment of the early cloth-covered Starr-Edwards mitral valve prosthesis. Pietras RJ; Long DM; Rosen KM J Thorac Cardiovasc Surg; 1974 Mar; 67(3):450-8. PubMed ID: 4273221 [No Abstract] [Full Text] [Related]
15. Late death due to escape of ball from mitral valve prosthesis. Keen G J Thorac Cardiovasc Surg; 1974 Feb; 67(2):202-7. PubMed ID: 4810992 [No Abstract] [Full Text] [Related]
16. Fatal thrombosis of the Starr-Edwards mitral valve prosthesis associated with bacterial endocarditis. Diagnostic significance of a disappearing prosthetic click. Cheng TO; Kinhal V; Tice DA Chest; 1970 Feb; 57(2):151-5. PubMed ID: 5411716 [No Abstract] [Full Text] [Related]