These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
108 related articles for article (PubMed ID: 5413910)
1. X-ray sensitometer for screen-film combinations used in medical radiology. Haus AG; Rossmann K Radiology; 1970 Mar; 94(3):673-8. PubMed ID: 5413910 [No Abstract] [Full Text] [Related]
3. [Film for exposure from the screen of an x-ray electron-optical transducer]. Leonova NI; Sidorov IuD; Dmitriev GI; Kameneva SI; Kotliarov PM Vestn Rentgenol Radiol; 1982; (4):59-61. PubMed ID: 7135811 [No Abstract] [Full Text] [Related]
4. [Photo-effect of the fluorescence from the opposite intensifying screen on the emulsion of the x-ray film]. Tanaka Y Nihon Igaku Hoshasen Gakkai Zasshi; 1971 Feb; 30(11):131-5. PubMed ID: 5291799 [No Abstract] [Full Text] [Related]
5. Technical note. Evaluation of a new screen/film combination. Evans AL; Davison M; McLellan J; James WB Br J Radiol; 1975 Oct; 48(574):858-9. PubMed ID: 1191907 [TBL] [Abstract][Full Text] [Related]
7. [Adjustment of the film tension and the film=screen combination in the detection of low contrast in x-ray diagnosis. II: Interpretation of the results and clinical implications]. Wust P; Hunger J; Claussen C; Felix R Rontgenpraxis; 1990 Jan; 43(1):25-37. PubMed ID: 2405504 [No Abstract] [Full Text] [Related]
8. [Extrafocal radiation of medical x-ray tubes with a rotating anode]. Juran R; Hinz R Radiol Diagn (Berl); 1990; 31(1):91-8. PubMed ID: 2343094 [TBL] [Abstract][Full Text] [Related]
9. [Acceptance test of film processing in roentgen diagnosis]. Hoeschen D; Buhr E Aktuelle Radiol; 1996 Jul; 6(4):203-5. PubMed ID: 8924456 [TBL] [Abstract][Full Text] [Related]
10. [Current role of x-ray technology in medical introscopy]. Blinov NN; Mazurov AI Med Tekh; 1998; (6):3-5. PubMed ID: 9949978 [TBL] [Abstract][Full Text] [Related]
11. Relative efficiencies of energy to photographic density conversions in typical screen-film systems. Vyborny CJ; Metz CE; Doi K Radiology; 1980 Aug; 136(2):465-71. PubMed ID: 7403525 [TBL] [Abstract][Full Text] [Related]
12. Problems associated with simulated light sensitometry for low-crossover medical x-ray films. Haus AG; Dickerson RE Med Phys; 1990; 17(4):691-5. PubMed ID: 2215416 [TBL] [Abstract][Full Text] [Related]
13. Backscatter from metal surfaces in diagnostic radiology. Kodera Y; Schmidt RA; Chan HP; Doi K Radiology; 1984 Jan; 150(1):231-4. PubMed ID: 6689765 [TBL] [Abstract][Full Text] [Related]
14. The application of fast screen-film systems to excretory urography. Stables DP; Rossi RP; Caruthers SB; Anderson N AJR Am J Roentgenol; 1977 Apr; 128(4):617-9. PubMed ID: 403791 [TBL] [Abstract][Full Text] [Related]
15. [Scientific and technical progress and medical roentgenology and radiology]. Krongauz AN Med Radiol (Mosk); 1977 Nov; 22(11):45-9. PubMed ID: 927052 [No Abstract] [Full Text] [Related]
16. [Effect of the x-ray tube, film and foil on the quality of the picture]. Lissner JA Rontgenpraxis; 1969 Jan; 22(1):7-20. PubMed ID: 5801166 [No Abstract] [Full Text] [Related]