BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

78 related articles for article (PubMed ID: 543192)

  • 1. [Measurement of regional and global coronary sinus blood flow with the continuous thermodilution technique. I. Method and experimental studies (author's transl)].
    Kupper W; Bleifeld W
    Z Kardiol; 1979 Nov; 68(11):740-7. PubMed ID: 543192
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Experimental evaluation of the reliance of coronary sinus blood flow (CSF) and great cardiac vein blood flow (GCVF) measured by local thermodilution method].
    Obata H; Nishijima H; Yasuda H
    Hokkaido Igaku Zasshi; 1991 Mar; 66(2):161-9. PubMed ID: 2060904
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Measurement of regional and global coronary sinus blood flow with the continuous thermodilution technique. II. Clinical studies in patients with coronary heart disease (author's transl)].
    Kupper W; Bleifeld W
    Z Kardiol; 1981 Feb; 70(2):116-23. PubMed ID: 7222905
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Continuous infusion thermodilution for assessment of coronary flow: theoretical background and in vitro validation.
    van't Veer M; Geven MC; Rutten MC; van der Horst A; Aarnoudse WH; Pijls NH; van de Vosse FN
    Med Eng Phys; 2009 Jul; 31(6):688-94. PubMed ID: 19237308
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Clinical estimation of the relation between coronary artery disease and regional myocardial blood flow by continuous thermodilution with the multithermistor catheter].
    Mikuniya A; Fukuhara Y; Fujino Y; Yamanaka T; Sekiguchi H; Narita H; Koh M; Momose A; Oike Y; Onodera K
    J Cardiogr; 1983 Jun; 13(2):291-300. PubMed ID: 6676378
    [TBL] [Abstract][Full Text] [Related]  

  • 6. New method for measurement of hepatic blood flow in the rat using thermodilution method.
    Sato T
    Circ Shock; 1987; 21(1):31-7. PubMed ID: 3815753
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Regional coronary outflow and coronary reserve assessed by the thermodilution technique: an experimental study].
    Kurita A; Shibuya T; Isojima K; Kondo S; Arakawa K; Mizuno K; Satomura K; Horiuchi K; Takase B; Nakamura H
    J Cardiogr; 1986 Jun; 16(2):353-61. PubMed ID: 3108415
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Measurement of coronary flow reserve by pressure/temperature sensor guide wire-based thermodilution in experimental models].
    Neishi Y; Akasaka T; Koyama Y; Akiyama M; Watanabe N; Kamiyama N; Kaji S; Saito Y; Suetsuna R; Yoshida K
    J Cardiol; 2002 Dec; 40(6):249-57. PubMed ID: 12528646
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Clinical application of monitoring techniques: coronary sinus blood flow monitoring.
    Specchia G; De Servi S; Poma E; Ghio S; Ferrario M; Angoli L; Ardissino D; Bramucci E; Mussini A
    Can J Cardiol; 1986 Jul; Suppl A():170A-172A. PubMed ID: 3756582
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The continuous thermodilution method for measuring high blood flows.
    Häggmark S; Biber B; Sjödin JG; Winsö O; Gustavsson B; Reiz S
    Scand J Clin Lab Invest; 1982 Jun; 42(4):315-21. PubMed ID: 7134816
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Coronary sinus blood flow determination by the thermodilution technique: influence of catheter position and respiration.
    Bagger JP
    Cardiovasc Res; 1985 Jan; 19(1):27-31. PubMed ID: 3986850
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Direct volumetric blood flow measurement in coronary arteries by thermodilution.
    Aarnoudse W; Van't Veer M; Pijls NH; Ter Woorst J; Vercauteren S; Tonino P; Geven M; Rutten M; van Hagen E; de Bruyne B; van de Vosse F
    J Am Coll Cardiol; 2007 Dec; 50(24):2294-304. PubMed ID: 18068038
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Estimation of cerebral blood flow at bedside by continuous jugular thermodilution.
    Mélot C; Berré J; Moraine JJ; Kahn RJ
    J Cereb Blood Flow Metab; 1996 Nov; 16(6):1263-70. PubMed ID: 8898700
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Measurement of coronary sinus flow by thermodilution: observations on the effect of respiration and a review of the potential sources of error.
    Stewart JT; Gray HH; Camm AJ
    Cathet Cardiovasc Diagn; 1989 Aug; 17(4):207-11. PubMed ID: 2670243
    [TBL] [Abstract][Full Text] [Related]  

  • 15. In vitro analysis of thermal transport in coronary sinus thermodilution catheters.
    Bålfors E; Häggmark S; Ariola S; Biber B; Pontèn J; Reiz S
    Clin Physiol; 1983 Oct; 3(5):469-76. PubMed ID: 6685599
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Coronary sinus venoarterial CO2 difference in different hemodynamic states.
    Vretzakis G; Ferdi E; Papaziogas B; Dragoumanis C; Pneumatikos J; Tsangaris I; Tsakiridis K; Konstantinou F
    Acta Anaesthesiol Belg; 2004; 55(3):221-7. PubMed ID: 15515299
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of cold stress on coronary sinus blood flow in patients with scleroderma.
    Colfer HT; Das SK; Dabich L; Randall OS; Pitt B
    J Assoc Acad Minor Phys; 1993; 4(2):62-5. PubMed ID: 8490289
    [TBL] [Abstract][Full Text] [Related]  

  • 18. In vivo validation of a thermodilution system designed to measure peripheral blood flow.
    Sullivan MJ; Beckley PD; Hanson KM; Leier CV
    Med Instrum; 1985; 19(1):38-40. PubMed ID: 3990598
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Regional coronary flow in ml/min measured with conventional coronarography].
    Chappuis F; Guggenheim N; Suilen C; Doriot PA; Descouts P; Rutishauser W
    Schweiz Med Wochenschr; 1992 Apr; 122(16):588-92. PubMed ID: 1579865
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Measurement of maximal coronary flow reserve: a technique for assessing the physiologic significance of coronary arterial lesions in humans.
    Wilson RF; White CW
    Herz; 1987 Jun; 12(3):163-76. PubMed ID: 3623398
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.