These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

79 related articles for article (PubMed ID: 5446536)

  • 1. Clinical and laboratory evaluation of a new synthetic absorbable suture.
    Kelly RJ
    Rev Surg; 1970; 27(2):142-3. PubMed ID: 5446536
    [No Abstract]   [Full Text] [Related]  

  • 2. Mechanical performance of polyglycolic acid and polyglactin 910 synthetic absorbable sutures.
    Rodeheaver GT; Thacker JG; Edlich RF
    Surg Gynecol Obstet; 1981 Dec; 153(6):835-41. PubMed ID: 6272438
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [New surgical suture: synthetic absorbable polyglycolic acid suture].
    Tanabe T; Nakajima S; Matsunami S; Tamura K; Shiono T
    Shujutsu; 1971 Feb; 25(2):273-9. PubMed ID: 5555099
    [No Abstract]   [Full Text] [Related]  

  • 4. [Synthetic absorbable suture material (PGA) compared with catgut].
    Holm-Jensen S; Agner E
    Ugeskr Laeger; 1974 Aug; 136(32):1785-90. PubMed ID: 4411074
    [No Abstract]   [Full Text] [Related]  

  • 5. Evaluation of an absorbable synthetic suture material.
    Echeverría E; Jiménez J
    Surg Gynecol Obstet; 1970 Jul; 131(1):1-14. PubMed ID: 4246183
    [No Abstract]   [Full Text] [Related]  

  • 6. The scientific basis for selecting surgical sutures.
    Lin KY; Farinholt HM; Reddy VR; Edlich RF; Rodeheaver GT
    J Long Term Eff Med Implants; 2001; 11(1-2):29-40. PubMed ID: 11495103
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of synthetic absorbable sutures in abdominal closure.
    Tiwari VS; Agarwal A
    J Indian Med Assoc; 1982 Feb; 78(3):37-40. PubMed ID: 6286779
    [No Abstract]   [Full Text] [Related]  

  • 8. Biomechanical and clinical performance of a new synthetic monofilament absorbable suture.
    Rodeheaver GT; Beltran KA; Green CW; Faulkner BC; Stiles BM; Stanimir GW; Traeland H; Fried GM; Brown HC; Edlich RF
    J Long Term Eff Med Implants; 1996; 6(3-4):181-98. PubMed ID: 10167360
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Pathophysiologic aspects, progressive and new developments in absorbable fully synthetic suture materials].
    Lünstedt B; Thiede A
    Zentralbl Chir; 1983; 108(8):470-7. PubMed ID: 6306952
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Coated Vicryl synthetic absorbable sutures.
    Conn J; Beal JM
    Surg Gynecol Obstet; 1980 Jun; 150(6):843-4. PubMed ID: 6990525
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Knotting abilities of a new absorbable monofilament suture: poliglecaprone 25 (Monocryl).
    Trimbos JB; Niggebrugge A; Trimbos R; Van Rijssel EJ
    Eur J Surg; 1995 May; 161(5):319-22. PubMed ID: 7662774
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of 10-0 polyglycolic acid and polyglactin suture in rabbit limbal wounds.
    Sugar A
    Ophthalmic Surg; 1980 Jan; 11(1):22-4. PubMed ID: 6244525
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of 9-0 polyglycolic acid and polyglactin suture in rabbit limbal wounds.
    Sugar A
    Ophthalmic Surg; 1980 May; 11(5):335-7. PubMed ID: 6247679
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparative study on biocompatibility and absorption times of three absorbable monofilament suture materials (Polydioxanone, Poliglecaprone 25, Glycomer 631).
    Molea G; Schonauer F; Bifulco G; D'Angelo D
    Br J Plast Surg; 2000 Mar; 53(2):137-41. PubMed ID: 10878837
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Tendon sutures with a new monofilament synthetic absorbable suture material (PDS-suture of 6-0 strength). Results of animal experiments].
    Albers W; Geldmacher J; Giedl H; Beyer W
    Chirurg; 1982 Mar; 53(3):168-71. PubMed ID: 6802585
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A review of absorbable suture materials in head & neck surgery and introduction of monocryl: a new absorbable suture.
    LaBagnara J
    Ear Nose Throat J; 1995 Jun; 74(6):409-15. PubMed ID: 7628331
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effectiveness of glycomer 631 monofilament sutures in closing musculoaponeurotic incisions.
    Rodeheaver GT; Salopek LS; Green CW; Foresman PA; Suber F; Neal JG; Edlich RF
    J Long Term Eff Med Implants; 1998; 8(3-4):225-31. PubMed ID: 10186968
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Use of an absorbable suture in cataract surgery].
    Bec P; Arné JL; Mathis A; Calvet JM; Brunerie M
    Bull Soc Ophtalmol Fr; 1982 Apr; 82(4):539-41. PubMed ID: 7105352
    [No Abstract]   [Full Text] [Related]  

  • 19. Evaluation of coated and uncoated synthetic absorbable sutures in rabbit limbal wounds.
    Sugar A; Bahn CF
    Ophthalmic Surg; 1982 Dec; 13(12):1006-7. PubMed ID: 6298682
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Mechanical and handling properties of braided polyblend polyethylene sutures in comparison to braided polyester and monofilament polydioxanone sutures.
    Wüst DM; Meyer DC; Favre P; Gerber C
    Arthroscopy; 2006 Nov; 22(11):1146-53. PubMed ID: 17084288
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.