These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

173 related articles for article (PubMed ID: 5461)

  • 1. High-pressure liquid chromatography of drugs. II. An evaluation of a microparticulate cation-exchange column.
    Twitchett PJ; Gorvin AE; Moffat AC
    J Chromatogr; 1976 May; 120(2):359-68. PubMed ID: 5461
    [TBL] [Abstract][Full Text] [Related]  

  • 2. HPLC of basic drugs on microparticulate strong cation-exchange materials - a review.
    Flanagan RJ; Harvey EJ; Spencer EP
    Forensic Sci Int; 2001 Sep; 121(1-2):97-102. PubMed ID: 11516893
    [TBL] [Abstract][Full Text] [Related]  

  • 3. High-pressure liquid chromatography of drugs. An evaluation of an octadecylsilane stationary phase.
    Twitchett PJ; Moffat AC
    J Chromatogr; 1975 Aug; 111(1):149-57. PubMed ID: 239959
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Strong cation exchange column allow for symmetrical peak shape and increased sample loading in the separation of basic compounds.
    Long Z; Wang C; Guo Z; Zhang X; Nordahl L; Liang X
    J Chromatogr A; 2012 Sep; 1256():67-71. PubMed ID: 22885038
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Re-evaluation of anion-exchange HPLC for the analysis of acidic compounds.
    Law B; Hussain MA
    J Pharm Biomed Anal; 2000 Feb; 22(1):149-54. PubMed ID: 10727134
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Sample preparation in the micro-determination of organic compounds in plasma or urine.
    Reid E
    Analyst; 1976 Jan; 101(1198):1-18. PubMed ID: 1247179
    [No Abstract]   [Full Text] [Related]  

  • 7. High-performance liquid chromatographic analysis of basic drugs on silica columns using non-aqueous ionic eluents. I. Factors influencing retention, peak shape and detector response.
    Flanagan RJ; Jane I
    J Chromatogr; 1985 Apr; 323(2):173-89. PubMed ID: 2987280
    [TBL] [Abstract][Full Text] [Related]  

  • 8. High-performance cation-exchange chromatography of proteins.
    Gupta S; Pfannkoch E; Regnier FE
    Anal Biochem; 1983 Jan; 128(1):196-201. PubMed ID: 6303152
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Novel methylcellulose-immobilized cation-exchange precolumn for on-line enrichment of cationic drugs in plasma.
    Yamamoto E; Sakaguchi T; Kajima T; Mano N; Asakawa N
    J Chromatogr B Analyt Technol Biomed Life Sci; 2004 Aug; 807(2):327-34. PubMed ID: 15203047
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Retention reproducibility of basic drugs in high-performance liquid chromatography on a silica column with a methanol-ammonium nitrate eluent. The effect of the mobile phase and the operating conditions.
    Smith RM; Hurdley TG; Gill R; Osselton MD
    J Chromatogr; 1987 Jul; 398():73-87. PubMed ID: 3654853
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Novel cation-exchange column for the separation of hydrophobic and/or polyvalent amines.
    Rey M; Pohl C
    J Chromatogr A; 2003 May; 997(1-2):199-206. PubMed ID: 12830893
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Weak cation-exchange restricted-access material for on-line purification of basic drugs in plasma.
    Sato Y; Yamamoto E; Takakuwa S; Kato T; Asakawa N
    J Chromatogr A; 2008 May; 1190(1-2):8-13. PubMed ID: 18374926
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Ion-exchange and hydrophobic interactions affecting selectivity for neutral and charged solutes on three structurally similar agglomerated ion-exchange and mixed-mode stationary phases.
    Kazarian AA; Taylor MR; Haddad PR; Nesterenko PN; Paull B
    Anal Chim Acta; 2013 Nov; 803():143-53. PubMed ID: 24216208
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Influence of acidic eluent for retention behaviors of common anions and cations by ion-exclusion/cation-exchange chromatography on a weakly acidic cation-exchange resin in the H+ -form.
    Mori M; Tanaka K; Satori T; Ikedo M; Hu W; Itabashi H
    J Chromatogr A; 2006 Jun; 1118(1):51-5. PubMed ID: 16546200
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Chromatographic behavior of basic drugs on thioether-embedded benzenesulfonate silica stationary phases].
    Wang X; Chen L
    Se Pu; 2018 Sep; 36(9):850-857. PubMed ID: 30251512
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Chromatographic behaviour of alkaloids on thin layers of cation exchangers. II. Alginic acid, Rexyn 102, Dowex 50-X4 and CMCNa.
    Lepri L; Desideri PG; Lepori M
    J Chromatogr; 1976 Jul; 123(1):175-84. PubMed ID: 7570
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [The use of the ion exchange polymer Wofatit CP for sample preparation of drugs from urine for high pressure liquid chromatographic and spectrophotometric determinations].
    Witte P; Wolff M
    Pharmazie; 1990 Jul; 45(8):572-5. PubMed ID: 2080201
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Retention behaviour of acidic, neutral and basic drugs on a CN column using phosphate buffers in the mobile phase.
    De Smet M; Massart DL
    J Chromatogr; 1987 Nov; 410(1):77-94. PubMed ID: 3429557
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Retention of alkali, alkaline earth and transition metals on an itaconic acid cation-exchange column. Eluent pH, ionic strength and temperature effects upon selectivity.
    Bashir W; Tyrrell E; Feeney O; Paull B
    J Chromatogr A; 2002 Jul; 964(1-2):113-22. PubMed ID: 12198839
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Characterization of a microparticulate strong anion-exchanger in the HPLC of acidic drugs.
    Morgan PE; Hanna-Brown M; Flanagan RJ
    Biomed Chromatogr; 2006 Aug; 20(8):765-73. PubMed ID: 16292744
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.