These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

121 related articles for article (PubMed ID: 5485467)

  • 1. The energy response of LiF, CaF2 and Li2B4O7 to high energy radiations.
    Burlin TE
    Phys Med Biol; 1970 Jul; 15(3):558-61. PubMed ID: 5485467
    [No Abstract]   [Full Text] [Related]  

  • 2. The energy response of LiF, CaF2, and Li2B4O7: Mn to high energy radiations.
    Almond PR; McCray K
    Phys Med Biol; 1970 Apr; 15(2):335-42. PubMed ID: 5484876
    [No Abstract]   [Full Text] [Related]  

  • 3. A Monte Carlo study of the quality dependence factors of common TLD materials in photon and electron beams.
    Mobit PN; Nahum AE; Mayles P
    Phys Med Biol; 1998 Aug; 43(8):2015-32. PubMed ID: 9725586
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Energy dependence of LiF and CaF2 thermoluminescent dosimeters for high energy electrons.
    Nakajima T; Hiraoka T; Habu T
    Health Phys; 1968 Mar; 14(3):266-7. PubMed ID: 5637399
    [No Abstract]   [Full Text] [Related]  

  • 5. Pion dosimetry with thermoluminescent materials.
    Hoffmann W; Möller G; Blattmann H; Salzmann M
    Phys Med Biol; 1980 Sep; 25(5):913-21. PubMed ID: 7454772
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The response of thermoluminescent dosimetric lithium borates equivalent to air, water and soft tissue and of LiF TLD-100 to low energy x-rays.
    Jayachandran CA
    Phys Med Biol; 1970 Apr; 15(2):325-34. PubMed ID: 5484875
    [No Abstract]   [Full Text] [Related]  

  • 7. LiF and CaF2:Mn thermoluminescent dosimeters in tandem.
    Gorbics SG; Attix FH
    Int J Appl Radiat Isot; 1968 Feb; 19(2):81-9. PubMed ID: 5639088
    [No Abstract]   [Full Text] [Related]  

  • 8. [Thermoluminescence dosimetry. 1. Basic research].
    Tanaka Y; Kuroda Y; Takahashi M
    Nihon Igaku Hoshasen Gakkai Zasshi; 1968 Aug; 28(5):536-45. PubMed ID: 5248443
    [No Abstract]   [Full Text] [Related]  

  • 9. The energy-size dependence of the response of thermoluminescent dosimeters to photon irradiation.
    Chan FK; Burlin TE
    Health Phys; 1970 Apr; 18(4):325-32. PubMed ID: 5513057
    [No Abstract]   [Full Text] [Related]  

  • 10. Thermoluminescent response of lithium fluoride to high-energy electrons.
    Suntharalingam N; Cameron JR
    Ann N Y Acad Sci; 1969 Jul; 161(1):77-85. PubMed ID: 4979832
    [No Abstract]   [Full Text] [Related]  

  • 11. Mass attenuation and mass energy absorption coefficients for LiF and Li2B407 for photons from 1 to 150 keV.
    Greening JR; Law J; Redpath AT
    Phys Med Biol; 1972 Jul; 17(4):585-7. PubMed ID: 5072024
    [No Abstract]   [Full Text] [Related]  

  • 12. DAMAGE EFFECTS IN CAF2:MN AND LIF THERMOLUMINESCENT DOSIMETERS.
    MARRONE MJ; ATTIX FH
    Health Phys; 1964 Jun; 10():431-6. PubMed ID: 14170714
    [No Abstract]   [Full Text] [Related]  

  • 13. LiF and CaF2: Dy thermoluminescent dosimeters.
    Tsuda M; Ohizumi Y; Mori T
    Strahlentherapie; 1980; 156(10):708-13. PubMed ID: 7434378
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Thermoluminescent response of lithium fluoride to radiations with different LET.
    Suntharalingam N; Cameron JR
    Phys Med Biol; 1969 Jul; 14(3):397-410. PubMed ID: 5789345
    [No Abstract]   [Full Text] [Related]  

  • 15. Surface effects of high-energy X rays at oblique incidence.
    Jackson W
    Br J Radiol; 1971 Feb; 44(518):109-15. PubMed ID: 4994161
    [No Abstract]   [Full Text] [Related]  

  • 16. [Intercomparisonin Japan of dosimetry for high energy electrons using mailed LiF-TLD].
    Kato Y; Shiragai A; Kumamoto Y; Maruyama T; Yoshida Y
    Nihon Igaku Hoshasen Gakkai Zasshi; 1969 Apr; 29(1):7-11. PubMed ID: 5255728
    [No Abstract]   [Full Text] [Related]  

  • 17. [Measurements of the dose distributions of high-energy electron beams with a LiF thermoluminescent dosimeter].
    Shiragai A; Noda H; Kato Y
    Nihon Igaku Hoshasen Gakkai Zasshi; 1969 Jan; 28(10):1360-4. PubMed ID: 5252801
    [No Abstract]   [Full Text] [Related]  

  • 18. The energy response of LiF, film and a chemical dosemeter to high energy photons and electrons.
    Bistrović M; Maricić Z; Greenfield MA; Breyer B; Dvornik I; Slaus I; Tomas P
    Phys Med Biol; 1976 May; 21(3):414-21. PubMed ID: 935255
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Assessment of the mean glandular dose using LiF:Mg,Ti, LiF:Mg,Cu,P, Li2B4O7:Mn and Li2B4O7:Cu TL detectors in mammography radiation fields.
    Fartaria MJ; Reis C; Pereira J; Pereira MF; Cardoso JV; Santos LM; Oliveira C; Holovey V; Pascoal A; Alves JG
    Phys Med Biol; 2016 Sep; 61(17):6384-99. PubMed ID: 27499104
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Letter: Energy dependence of lithium fluoride dosemeter for high energy electrons.
    Antoku S; Sunayashiki T; Takeoka S; Takeshita K
    Phys Med Biol; 1973 Nov; 18(6):889-91. PubMed ID: 4778454
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 7.