4. [Cooperative test on quality control 1968]. Stamm D; Büttner H Z Klin Chem Klin Biochem; 1970 Sep; 7(5):393-403. PubMed ID: 5505951 [No Abstract] [Full Text] [Related]
5. Studies of the stability of 18 chemical constituents of human serum. Wilson SS; Guillan RA; Hocker EV Clin Chem; 1972 Dec; 18(12):1498-503. PubMed ID: 4639860 [No Abstract] [Full Text] [Related]
6. [Differences between the normal levels of some blood substances in clinical chemistry]. Montgrain C Can J Med Technol; 1971 Apr; 33(2):60-70. PubMed ID: 5091613 [No Abstract] [Full Text] [Related]
7. On the design of clinical chemistry quality-control sera. Grannis GF; Miller WG Clin Chem; 1976 Apr; 22(4):500-12. PubMed ID: 1253433 [TBL] [Abstract][Full Text] [Related]
8. Statistics of patient test values: application to indirect normal range and to quality control. Glick JH Clin Chem; 1972 Dec; 18(12):1504-13. PubMed ID: 4639861 [No Abstract] [Full Text] [Related]
9. An attempt to reduce the interlaboratory variability of clinical chemistry results in a cooperative clinical investigation programme using a common reference serum. Elion-Gerritzen WE; Schippers HM Z Klin Chem Klin Biochem; 1974 May; 12(5):253. PubMed ID: 4613042 [No Abstract] [Full Text] [Related]
10. Analysis of results of the 1969 comprehensive chemistry survey of the College of American Pathologists. Gilbert RK Am J Clin Pathol; 1970 Sep; 54(3):463-82. PubMed ID: 4195907 [No Abstract] [Full Text] [Related]
11. The performance of delta check methods. Sheiner LB; Wheeler LA; Moore JK Clin Chem; 1979 Dec; 25(12):2034-7. PubMed ID: 509702 [TBL] [Abstract][Full Text] [Related]
12. Cooperative survey of "SMA" analyzers in Wisconsin. A method of improving interlaboratory performance. Laessig RH; Schwartz TH; Paskey TA Clin Chem; 1973 Jan; 19(1):62-6. PubMed ID: 4683369 [No Abstract] [Full Text] [Related]
13. An assessment of the "average of normals" quality control method. Kilgariff M; Owen JA Clin Chim Acta; 1968 Feb; 19(2):175-9. PubMed ID: 5645488 [No Abstract] [Full Text] [Related]
14. Between-bottle variation as source of error in quality control sera. Padmore GR; Gatt JA Clin Chem; 1970 Jan; 16(1):15-7. PubMed ID: 4984166 [No Abstract] [Full Text] [Related]
15. [Quality control of clinical-chemical determinations]. Büttner H; Stamm D Z Klin Chem Klin Biochem; 1966 Nov; 4(6):303-6. PubMed ID: 5992846 [No Abstract] [Full Text] [Related]
16. [Performance evaluation of the Piccolo xpress Point-of-care Chemistry Analyzer]. Park H; Ko DH; Kim JQ; Song SH Korean J Lab Med; 2009 Oct; 29(5):430-8. PubMed ID: 19893352 [TBL] [Abstract][Full Text] [Related]
17. Action limits for internal quality control. Lewis PW; Dixon K Clin Chim Acta; 1971 Nov; 35(1):21-32. PubMed ID: 5126996 [No Abstract] [Full Text] [Related]
19. Experience with the technicon autoanalyser II system in a routine laboratory. Georges RJ; Politzer WM S Afr Med J; 1972 Feb; 46(9):208-13. PubMed ID: 5017114 [No Abstract] [Full Text] [Related]
20. The size and the source of analytic error in clinical chemistry. Gilbert RK Am J Clin Pathol; 1974 Jun; 61(6):904-11. PubMed ID: 4841266 [No Abstract] [Full Text] [Related] [Next] [New Search]