These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

203 related articles for article (PubMed ID: 5549290)

  • 1. Toxicity of ethylene oxide sterilization of polyvinyl chloride in open-heart surgery.
    Stanley P; Bertranou E; Forest F; Langevin L
    J Thorac Cardiovasc Surg; 1971 Feb; 61(2):309-14. PubMed ID: 5549290
    [No Abstract]   [Full Text] [Related]  

  • 2. [Rare complication of open heart surgery--ruptured aneurysm of the femoral artery possibly due to the residual ethylene oxide following gas sterilization].
    Kugimiya T; Shirabe J; Kusaba E; Hadama T; Kuroiwa M
    Kyobu Geka; 1975 Dec; 28(12):874-8. PubMed ID: 1239621
    [No Abstract]   [Full Text] [Related]  

  • 3. Exposure of patients to ethylene oxide during cardiopulmonary bypass using gas-sterilized pump components.
    Lindop CR; Willcox TW; McKegg PM; Harris EA
    J Thorac Cardiovasc Surg; 1980 Jun; 79(6):845-50. PubMed ID: 7374200
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Clinical research of open heart surgery in infancy and early childhood under extracorporeal circulation (body weight under 10 kg). I. Equipment of heart-lung machine, method of extracorporeal circulation, and clinial result.
    Mao LM
    Nihon Geka Hokan; 1972 Jun; 41(1):3-14. PubMed ID: 4673749
    [No Abstract]   [Full Text] [Related]  

  • 5. [Anesthetic experience with open heart surgery under extracorporeal circulation with 5 percent glucose solution].
    Ishida H; Horiguchi S; Morikawa S; Hayashi T; Katsura Y
    Masui; 1966 Jun; 15(6):546-51. PubMed ID: 6007289
    [No Abstract]   [Full Text] [Related]  

  • 6. [Retention of ethylene oxide after sterilization of polyvinyl chloride and polyethylene material].
    Lacomme M; Le Moan G; Chaigneau M
    Ann Pharm Fr; 1975; 33(6-7):337-44. PubMed ID: 1220602
    [No Abstract]   [Full Text] [Related]  

  • 7. [The effect of sterilization by ethylene oxide on residual amounts of chlorohydrin and ethylene glycol in medical devices made of PVC, previously irradiated by cobalt 60].
    de Seille JM; Delattre L; Meurice L; Jaminet F
    J Pharm Belg; 1985; 40(4):213-21. PubMed ID: 4067806
    [No Abstract]   [Full Text] [Related]  

  • 8. An outbreak of hemorrhage following cardiopulmonary bypass. Epidemiologic studies.
    Brooks DH; Bahnson HT
    J Thorac Cardiovasc Surg; 1972 Mar; 63(3):449-52. PubMed ID: 5011284
    [No Abstract]   [Full Text] [Related]  

  • 9. Recent advances in medicine and surgery. Current status of cardiac surgery. I.
    Giannelli S; Conklin EF; Ayres SM; Kozam R; Bordiuk J; Gregory JJ
    N Y State J Med; 1968 Oct; 68(20):2660-72. PubMed ID: 4972104
    [No Abstract]   [Full Text] [Related]  

  • 10. [Importance of the lung-heart appliance in open-heart surgery with extracorporeal circulation].
    Antoszewski Z
    Pol Przegl Chir; 1977 Mar; 49(3):381-5. PubMed ID: 846925
    [No Abstract]   [Full Text] [Related]  

  • 11. [Control of diuresis in open-heart surgery in extracorporeal circulation].
    Fantera A
    Acta Anaesthesiol; 1970; 21(6):807-20. PubMed ID: 5538139
    [No Abstract]   [Full Text] [Related]  

  • 12. [Clinical application of a pulsatile pump to extracorporeal circulation].
    Kubo K; Kusagawa M; Yuasa H; Yada I; Omori S
    Saishin Igaku; 1971 Jun; 26(6):1165-72. PubMed ID: 5098181
    [No Abstract]   [Full Text] [Related]  

  • 13. [Endotoxic reaction observed at the beginning of collapse and neutropenia following intracavity exploration].
    Seigneurin D; Rossignol B
    Nouv Presse Med; 1978 Apr; 7(14):1207-8. PubMed ID: 662649
    [No Abstract]   [Full Text] [Related]  

  • 14. [Developmental mechanism of pulmonary insufficiency after open heart surgery].
    Iyomasa Y; Shimizu T; Kogure T; Okamura N; Yokochi H
    Nihon Kyobu Geka Gakkai Zasshi; 1972 Aug; 20(8):643-51. PubMed ID: 4676880
    [No Abstract]   [Full Text] [Related]  

  • 15. [Open heart surgery using extracorporeal circulation with special reference to postoperative complications].
    Kobayashi K; Yamamoto H; Inoue R; Hitomi S; Kuroda R
    Iryo; 1966 Aug; 20(8):846-51. PubMed ID: 5974820
    [No Abstract]   [Full Text] [Related]  

  • 16. Clinical use of membrane lung. Discussion.
    Mt Sinai J Med; 1973; 40(2):237-48. PubMed ID: 4540372
    [No Abstract]   [Full Text] [Related]  

  • 17. [Studies of the open heart surgery under circulatory arrest induced by profound hypothermia in extracorporeal circulation. (1). Effect of the arrest on the brain metabolism].
    Kuchiba K
    Igaku Kenkyu; 1966 Oct; 36(5):602-19. PubMed ID: 6009289
    [No Abstract]   [Full Text] [Related]  

  • 18. Aeration of medical plastics.
    Tock RM; Chen YC
    J Biomed Mater Res; 1974 Jan; 8(1):69-80. PubMed ID: 4819875
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Clinical research of open heart surgery in infancy and early childhood under extracorporeal circulation (body weight under 10 kg). II. Blood dilution rate, perfusion rate of extracorporeal circulation, and postoperative rapid diuuretic method].
    Mao LM
    Nihon Geka Hokan; 1972 Jun; 41(1):15-31. PubMed ID: 4673746
    [No Abstract]   [Full Text] [Related]  

  • 20. [Health hazards in hospital personnel related to use of ethylene oxide in sterilization processes].
    Tyras H
    Med Pr; 1997; 48(3):325-33. PubMed ID: 9312659
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.