These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

132 related articles for article (PubMed ID: 5573463)

  • 1. [Reliable measurements of intraocular pressure in infants using the Mackay-Marg electronic tonometer without general and local anesthesia].
    Mucsi G; Littmann J; Follmann P
    Klin Monbl Augenheilkd; 1971 Mar; 158(3):417-21. PubMed ID: 5573463
    [No Abstract]   [Full Text] [Related]  

  • 2. Electronic tonometry in the newborn.
    Dominguez A; Alvarez MG; Banos MS
    Adv Ophthalmol; 1975; 29():88-125. PubMed ID: 1130240
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Measurement of ocular tension in the newborn with the Mackay-Marg electronic tonometer].
    Trux E; Follmann P
    Bull Mem Soc Fr Ophtalmol; 1969; 82():48-53. PubMed ID: 5402423
    [No Abstract]   [Full Text] [Related]  

  • 4. Non-contact and Mackay-Marg tonometry: comparison in patients ages 7 to 85 years.
    Augsburger A; Terry JE
    Am J Optom Physiol Opt; 1977 Jan; 54(1):31-4. PubMed ID: 871146
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Intraocular pressure measurement in children using the Keeler Pulsair tonometer.
    Evans K; Wishart PK
    Ophthalmic Physiol Opt; 1992 Jul; 12(3):287-90. PubMed ID: 1454364
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Suggestion of a calibration procedure for the Mackay-Marg tonometer].
    Jessen K; Söllner F
    Ber Zusammenkunft Dtsch Ophthalmol Ges; 1975; (73):344-9. PubMed ID: 1242945
    [No Abstract]   [Full Text] [Related]  

  • 7. [The Mackay-Marg tonometer. A report to the committee for the standardization of tonometers].
    Moses RA
    Klin Monbl Augenheilkd; 1968; 153(4):597-604. PubMed ID: 5714773
    [No Abstract]   [Full Text] [Related]  

  • 8. [Alterations in intraocular pressure in children examined by Goldmann's applanation tonometer under general anesthesia].
    Degenne S; Benck P; Gerhard JP; Payeur G; Roth A
    Arch Ophtalmol Rev Gen Ophtalmol; 1968 Jun; 28(4):359-74. PubMed ID: 4234513
    [No Abstract]   [Full Text] [Related]  

  • 9. Evaluation of electronic tonometers in the rabbit eye.
    Gelatt KN; Gum GG
    Am J Vet Res; 1981 Oct; 42(10):1778-81. PubMed ID: 7325441
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Intraocular pressure of young children under anesthesia].
    Weekers R; Prijot E; Henrotte J; Engels G
    Arch Ophtalmol Rev Gen Ophtalmol; 1974 Apr; 34(4):241-50. PubMed ID: 4277216
    [No Abstract]   [Full Text] [Related]  

  • 11. [The Mackay-Marg-tonometer. A clinically applicable measuring apparatus for Pt-values (author's transl)].
    Stepanik J
    Klin Monbl Augenheilkd; 1975 Nov; 167(5):753-5. PubMed ID: 1206959
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Changes in intraocular pressure in children under general anesthesia].
    Degenne S; Benck P; Gerhard JP; Payeur G; Roth A
    Bull Soc Ophtalmol Fr; 1967 Dec; 67(12):1118-21. PubMed ID: 4393247
    [No Abstract]   [Full Text] [Related]  

  • 13. A comparison of intraocular pressure measurements with the XPERT noncontact tonometer and Goldmann applanation tonometry.
    Popovich KS; Shields MB
    J Glaucoma; 1997 Feb; 6(1):44-6. PubMed ID: 9075080
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Intraocular pressure measurements in infants without glaucoma under halothane anesthesia].
    Grote P
    Ophthalmologica; 1975; 171(3):202-6. PubMed ID: 1134759
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Tonometric value in childhood.
    Coppieters R
    Bull Soc Belge Ophtalmol; 1982; 202():153-7. PubMed ID: 7184610
    [No Abstract]   [Full Text] [Related]  

  • 16. Clinical comparison of the tonomat applanation tonometer with the Mackay-Marg electronic tonometer.
    Hill JF; Hill PJ
    Am J Optom Arch Am Acad Optom; 1969 Oct; 46(10):797-800. PubMed ID: 5259640
    [No Abstract]   [Full Text] [Related]  

  • 17. Estimation of intraocular pressure in rabbits using noncontact tonometer: a comparative evaluation with Schiotz tonometer.
    Gupta SK; Saxena R; Agarwal R; Galpalli ND; Srivastava S; Agrawal SS
    Methods Find Exp Clin Pharmacol; 2007; 29(6):405-9. PubMed ID: 17922069
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Constant-area applanation tonography.
    Moses RA; Grodzki WJ; Arnzen RJ
    Invest Ophthalmol Vis Sci; 1981 Jun; 20(6):722-5. PubMed ID: 7239844
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Intraocular pressure measurement in infants under general anesthesia.
    Dominguez A; Baños S; Alvarez G; Contra GF; Quintela FB
    Am J Ophthalmol; 1974 Jul; 78(1):110-6. PubMed ID: 4835062
    [No Abstract]   [Full Text] [Related]  

  • 20. Assessment of intraocular pressure in children by digital tension.
    Ficarra AP; Sorkin R; Morrison C
    Optometry; 2002 Aug; 73(8):499-506. PubMed ID: 12365673
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.