  • 1. Cloth destruction and haemolysis with totally cloth-covered Starr-Edwards prostheses.
    Schottenfeld M; Wisheart JD; Ross JK; Lincoln JC; Ross DN
    Thorax; 1971 Mar; 26(2):159-62. PubMed ID: 5576531
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Severe hemolysis due to cloth wear 23 years after aortic valve replacement on a Starr-Edwards ball valve model 2320.
    Murakami M; Tanaka H; Watanabe M; Shimizu M; Sunamori M
    Cardiovasc Surg; 2002 Jun; 10(3):284-6. PubMed ID: 12044439
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Severe hemolysis with a fabric-worn cloth-covered aortic valve prosthesis.
    Pierach CA; Baur HR; Kiser JC
    Chest; 1975 Apr; 67(4):486-7. PubMed ID: 1122782
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Hemolysis in Starr-Edwards cloth-covered mitral valve prostheses.
    Wanderman KL; Dvilansky A; Yoran C; Gueron M
    Am Heart J; 1975 Sep; 90(3):405-6. PubMed ID: 1163431
    [No Abstract]   [Full Text] [Related]  

  • 5. Hemolysis in the aortic prosthetic valve.
    Santinga JT; Batsakis JT; Flora JD; Kirsh MM
    Chest; 1976 Jan; 69(1):56-61. PubMed ID: 1244290
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Indication to Starr-Edwards aortic-valve-replacement because of cloth-destruction and hemolysis (author's transl)].
    Walter P; Dalichau H; Oelert H; Hempelmann G; Borst HG
    Thoraxchir Vask Chir; 1974 Dec; 22(6):626-31. PubMed ID: 4548974
    [No Abstract]   [Full Text] [Related]  

  • 7. Complications due to cloth wear in cloth-covered Starr-Edwards aortic and mitral valve prostheses--and their management.
    Shah A; Dolgin M; Tice DA; Trehan N
    Am Heart J; 1978 Sep; 96(3):407-14. PubMed ID: 685811
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Hyposideraemia and haemolysis in patients with Lillehei-Kaster or Starr-Edwards heart valve prostheses.
    Andersen JD; Lyngborg K; Wennevold A; Rygg I; Olesen KH
    Scand J Thorac Cardiovasc Surg; 1979; 13(3):271-5. PubMed ID: 542832
    [No Abstract]   [Full Text] [Related]  

  • 9. Wear of the metallic studs on the composite seat of the 2320 Starr-Edwards aortic valve and its clinical consequences.
    Warnes CA; McIntosh CL; Roberts WC
    Am J Cardiol; 1983 Nov; 52(8):1062-5. PubMed ID: 6637825
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Chronic hemolysis following fascia lata and Starr-Edwards aortic valve replacement.
    Dave KS; Madan CK; Pakrashi BC; Roberts BE; Ionescu MI
    Circulation; 1972 Aug; 46(2):240-9. PubMed ID: 5046019
    [No Abstract]   [Full Text] [Related]  

  • 11. Fatal coronary obstruction due to cloth-wear of a cloth-covered Starr-Edwards aortic valve prosthesis.
    Maroñas JM; Such M; Sánchez P; González-Pont G; Caffarena JM
    Chest; 1982 Nov; 82(5):645-6. PubMed ID: 7128232
    [No Abstract]   [Full Text] [Related]  

  • 12. [Case of acute hemolytic anemia caused by "cloth wear" following aortic valve replacement by Starr-Edwards ball valve Model 2400, 9A].
    Maeda S; Miyamoto T; Shimizu Y; Ozawa M; Ohashi H; Oka Y; Tomita E; Yamashita K; Ogawa N
    Nihon Kyobu Geka Gakkai Zasshi; 1982 Jul; 30(7):1285-90. PubMed ID: 7175269
    [No Abstract]   [Full Text] [Related]  

  • 13. Complications following destruction of the cloth covering of a Starr-Edwards aortic valve prosthesis.
    Boruchow IB; Ramsey HW; Wheat MW
    J Thorac Cardiovasc Surg; 1971 Aug; 62(2):290-3. PubMed ID: 5560513
    [No Abstract]   [Full Text] [Related]  

  • 14. Haemolysis with Björk-Shiley and Starr-Edwards prosthetic heart valves: a comparative study.
    Slater SD; Sallam IA; Bain WH; Turner MA; Lawrie TD
    Thorax; 1974 Nov; 29(6):624-32. PubMed ID: 4450173
    [No Abstract]   [Full Text] [Related]  

  • 15. Hemolytic phenomena following insertion of the cloth-covered Starr-Edwards valve prosthesis.
    Yacoub MH; Lise M; Patterson M; Ross DN
    Ann Thorac Surg; 1969 Aug; 8(2):161-5. PubMed ID: 5798831
    [No Abstract]   [Full Text] [Related]  

  • 16. Iron treatment in sideropenic intravascular hemolysis due to insufficiency of Starr-Edwards valve prostheses.
    Reynolds RD; Coltman CA; Beller BM
    Ann Intern Med; 1967 Apr; 66(4):659-66. PubMed ID: 6023532
    [No Abstract]   [Full Text] [Related]  

  • 17. Late re-operation for aortic and mitral Starr-Edwards ball valve prostheses.
    Aoyagi S; Fukunaga S; Arinaga K; Yokokura Y; Yokokura H; Egawa N
    Asian Cardiovasc Thorac Ann; 2006 Dec; 14(6):467-71. PubMed ID: 17130320
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Intravascular haemolysis after valve replacement: comparative study between Starr-Edwards (ball valve) and Björk-Shiley (disc valve) prosthesis.
    Falk RH; Mackinnon J; Wainscoat J; Melikian V; Bignell AH
    Thorax; 1979 Dec; 34(6):746-8. PubMed ID: 542913
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Cloth cover wear of the struts of the Starr-Edwards aortic valve prosthesis. A case report.
    Ablaza SG; Blanco G; Javan MB; Maranhao V; Goldberg H
    J Thorac Cardiovasc Surg; 1971 Feb; 61(2):315-8. PubMed ID: 5549291
    [No Abstract]   [Full Text] [Related]  

  • 20. Chronic hemolysis following mitral valve replacement. A comparison of the frame-mounted aortic homograft and the composite seat Starr-Edwards prosthesis.
    Donnelly RJ; Rahman AN; Manohitharajah SM; Deverall PB; Watson DA
    Circulation; 1973 Oct; 48(4):823-9. PubMed ID: 4744788
    [No Abstract]   [Full Text] [Related]  