  • 1. Measurements of 6 MV x-rays. I. Primary radiation absorption in lead, steel and concrete.
    Karzmark CJ; Capone T
    Br J Radiol; 1968 Jan; 41(481):33-9. PubMed ID: 5634450
    [No Abstract]   [Full Text] [Related]  

  • 2. Some measurements on the absorption of 4 MV x rays in concrete.
    GREENE D; MASSEY JB
    Br J Radiol; 1961 Jun; 34():389-91. PubMed ID: 13708287
    [No Abstract]   [Full Text] [Related]  

  • 3. Attenuation in Lipowitz's metal of x rays produced at 2, 4, 10, and 18 MV and gamma rays from cobalt-60.
    Huen A; Findley DO; Skov DD
    Med Phys; 1979; 6(2):147-8. PubMed ID: 460064
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Attenuation of 4-32 MV x-rays in ordinary concrete, heavy concrete, iron and lead.
    Maruyama T; Kumamoto Y; Kato Y; Hashizume T; Yamamoto M
    Health Phys; 1971 Mar; 20(3):277-84. PubMed ID: 5090003
    [No Abstract]   [Full Text] [Related]  

  • 5. An empirical model for x-ray attenuation in Pb and mild steel.
    Okunade AA; Hussain LA
    Health Phys; 1989 Jun; 56(6):943-6. PubMed ID: 2722518
    [No Abstract]   [Full Text] [Related]  

  • 6. Tenth value layers for 60Co gamma rays and for 4, 6, 10, 15, and 18 MV x rays in concrete for beams of cone angles between 0 degrees and 14 degrees calculated by Monte Carlo simulation.
    Jaradat AK; Biggs PJ
    Health Phys; 2007 May; 92(5):456-63. PubMed ID: 17429304
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Measurements on the attenuation of 4 MV x rays in barytes concrete.
    Ormsby PL; Roberts GC
    Br J Radiol; 1968 Mar; 41(483):235-6. PubMed ID: 4966727
    [No Abstract]   [Full Text] [Related]  

  • 8. Do angles of obliquity apply to 30 degrees scattered radiation from megavoltage beams?
    Biggs PJ; Styczynski JR
    Health Phys; 2008 Oct; 95(4):425-32. PubMed ID: 18784515
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Analysis of tenth-value-layers for common shielding materials for a robotically mounted stereotactic radiosurgery machine.
    Rodgers JE
    Health Phys; 2007 Apr; 92(4):379-86. PubMed ID: 17351503
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Calculation of conversion coefficients for air kerma to ambient dose equivalent using transmitted spectra of megavoltage X-rays through concrete.
    Cordeiro TP; Silva AX
    Radiat Prot Dosimetry; 2012 Dec; 152(4):455-62. PubMed ID: 22683619
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of transmission data of diagnostic X rays through concrete using Monte Carlo simulation.
    Noto K; Koshida K; Iida H; Fukuda A
    Radiat Prot Dosimetry; 2009 Feb; 133(3):144-52. PubMed ID: 19307234
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Evaluation of correlation between radioactivity and exposure rate of irradiated concrete and stainless steel].
    Nakamura T; Hara A
    Radioisotopes; 1983 Dec; 32(12):602-8. PubMed ID: 6676778
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Measurements of 6 MV x rays. II. Characteristics of secondary radiation.
    Karzmark CJ; Capone T
    Br J Radiol; 1968 Mar; 41(483):222-6. PubMed ID: 4966725
    [No Abstract]   [Full Text] [Related]  

  • 14. Kerma transmission through steel for a p(66)Be(49) neutron beam: an update.
    Ten Haken RK; Awschalom M; Rosenberg I
    Health Phys; 1983 Mar; 44(3):277-81. PubMed ID: 6832981
    [No Abstract]   [Full Text] [Related]  

  • 15. [Studies on the dependence of "dose effect" for X-rays of different energy].
    Bronstein JE; Krisjuk EM; Liberman AN; Sakovskaja MS
    Radiobiol Radiother (Berl); 1968; 9(5):573-80. PubMed ID: 5732460
    [No Abstract]   [Full Text] [Related]  

  • 16. Vagus nerve stimulator stability and interference on radiation oncology x-ray beams.
    Gossman MS; Ketkar A; Liu AK; Olin B
    Phys Med Biol; 2012 Oct; 57(20):N365-76. PubMed ID: 23032351
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Response of the alanine/ESR dosimetry system to MV X-rays relative to (60)Co radiation.
    Anton M; Kapsch RP; Krystek M; Renner F
    Phys Med Biol; 2008 May; 53(10):2753-70. PubMed ID: 18448875
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Studies on photoneutrons produced by 10 MV x rays (author's transl)].
    Uchida I
    Nihon Igaku Hoshasen Gakkai Zasshi; 1981 Jul; 41(7):633-53. PubMed ID: 6799933
    [No Abstract]   [Full Text] [Related]  

  • 19. Relative thickness of lead, concrete, and steel required for protection against narrow beams of x-rays.
    SINGER G; WYCKOFF HO; DAY FH
    J Res Natl Bur Stand (1934); 1947 Jun; 38(6):665-72. PubMed ID: 20256120
    [No Abstract]   [Full Text] [Related]  

  • 20. The new NMi orthovolt x-rays absorbed dose to water primary standard based on water calorimetry.
    de Prez LA; de Pooter JA
    Phys Med Biol; 2008 Jul; 53(13):3531-42. PubMed ID: 18552419
    [TBL] [Abstract][Full Text] [Related]  