4. A portable microsystem-based telemetric pressure and temperature measurement unit. Flick BB; Orglmeister R IEEE Trans Biomed Eng; 2000 Jan; 47(1):12-6. PubMed ID: 10646273 [TBL] [Abstract][Full Text] [Related]
5. Ultrasonic sensing of temperature of liquids using inexpensive narrowband piezoelectric transducers. Alzebda S; Kalashnikov AN IEEE Trans Ultrason Ferroelectr Freq Control; 2010 Dec; 57(12):2704-11. PubMed ID: 21156366 [TBL] [Abstract][Full Text] [Related]
6. Bi-directional flow sensor with a wide dynamic range for medical applications. Al-Salaymeh A; Jovanović J; Durst F Med Eng Phys; 2004 Oct; 26(8):623-37. PubMed ID: 15471690 [TBL] [Abstract][Full Text] [Related]
7. Study of the ultrasonic characteristics of the lens. Oguchi Y; van Marle GW; Eijskoot F; Henkes HE Bibl Ophthalmol; 1975; (83):252-8. PubMed ID: 1131225 [No Abstract] [Full Text] [Related]
8. Measurement of thermal diffusivity of biomaterials by focused ultrasonic beams (thermal pulse decay method by focused ultrasonic beams). Nakayama M; Tanishita K Biomed Mater Eng; 1994; 4(2):105-14. PubMed ID: 7920196 [TBL] [Abstract][Full Text] [Related]
9. Ultrasound velocimetry for hyperthermia control. Robert J; Marchal C; Drocourt M; Escanye JM; Thouvenot P; Gaulard ML; Tosser A Prog Clin Biol Res; 1982; 107():555-60. PubMed ID: 7167507 [No Abstract] [Full Text] [Related]
10. Characterization of measurement artefacts in fluoroptic temperature sensors: implications for laser thermal therapy at 810 nm. Davidson SR; Vitkin IA; Sherar MD; Whelan WM Lasers Surg Med; 2005 Apr; 36(4):297-306. PubMed ID: 15786482 [TBL] [Abstract][Full Text] [Related]
11. In utero measurement of ultrasonically induced fetal mouse temperature increases. Carnes KI; Drewniak JL; Dunn F Ultrasound Med Biol; 1991; 17(4):373-82. PubMed ID: 1949349 [TBL] [Abstract][Full Text] [Related]
13. Method for MRI-guided conformal thermal therapy of prostate with planar transurethral ultrasound heating applicators. Chopra R; Burtnyk M; Haider MA; Bronskill MJ Phys Med Biol; 2005 Nov; 50(21):4957-75. PubMed ID: 16237234 [TBL] [Abstract][Full Text] [Related]
14. Variability in effective radiating area at 1 MHz affects ultrasound treatment intensity. Straub SJ; Johns LD; Howard SM Phys Ther; 2008 Jan; 88(1):50-7. PubMed ID: 17940107 [TBL] [Abstract][Full Text] [Related]
15. Non-invasive estimation of hyperthermia temperatures with ultrasound. Arthur RM; Straube WL; Trobaugh JW; Moros EG Int J Hyperthermia; 2005 Sep; 21(6):589-600. PubMed ID: 16147442 [TBL] [Abstract][Full Text] [Related]
16. [Electric thermometers and transducers for measuring human body temperature]. Fogel'son IB; Berdnikov SI; Zavitkov IuV Med Tekh; 1996; (4):28-30. PubMed ID: 8965662 [TBL] [Abstract][Full Text] [Related]
17. Radiation force calculations for ultrasonic fields from rectangular weakly focusing transducers. Beissner K J Acoust Soc Am; 2008 Oct; 124(4):1941-9. PubMed ID: 19062833 [TBL] [Abstract][Full Text] [Related]
18. An ultrasonic array sensor for spacecraft leak direction finding. Holland SD; Roberts R; Chimenti DE; Song JH Ultrasonics; 2006 Dec; 45(1-4):121-6. PubMed ID: 16950490 [TBL] [Abstract][Full Text] [Related]
19. Temperature rise of the post and on the root surface during ultrasonic post removal. Budd JC; Gekelman D; White JM Int Endod J; 2005 Oct; 38(10):705-11. PubMed ID: 16164684 [TBL] [Abstract][Full Text] [Related]
20. An example of thermometry in volume by microwave radiometry. Bocquet B; Van de Velde JC; Mamouni A; LeRoy Y IEEE Trans Biomed Eng; 1993 Sep; 40(9):990-2. PubMed ID: 8288291 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]