These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

109 related articles for article (PubMed ID: 564052)

  • 21. A NEW CUVETTE FOR THE SPECTROPHOTOMETRIC MEASUREMENT OF HEMOGLOBIN SATURATIONS.
    DANZER LA; COHN JE
    J Lab Clin Med; 1964 Feb; 63():355-8. PubMed ID: 14125124
    [No Abstract]   [Full Text] [Related]  

  • 22. Validation of the Edslab dual lumen oximetry catheter for continuous monitoring of jugular bulb oxygen saturation after severe head injury.
    Souter MJ; Andrews PJ
    Br J Anaesth; 1996 May; 76(5):744-6. PubMed ID: 8688282
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Continuous-flow reflecting oxyhemometer for extracorporeal circulation.
    Ballyuzek FV; Kiselev VG; Ul'yanov NA
    Biomed Eng (NY); 1968; 2(1):11-2. PubMed ID: 5761674
    [No Abstract]   [Full Text] [Related]  

  • 24. Study on the oxygenation velocity of the human red cell.
    Mochizuki M
    Jpn J Physiol; 1966 Dec; 16(6):635-48. PubMed ID: 5298360
    [No Abstract]   [Full Text] [Related]  

  • 25. Fibre optic reflection photometry on blood.
    Mook GA; Osypka P; Sturm RE; Wood EH
    Cardiovasc Res; 1968 Apr; 2(2):199-209. PubMed ID: 4872157
    [No Abstract]   [Full Text] [Related]  

  • 26. A sensitive dual wavelength microspectrophotometer for the measurement of tissue fluorescence and reflectance.
    Boldt M; Harbig K; Weidemann G; Lübbers DW
    Pflugers Arch; 1980 May; 385(2):167-73. PubMed ID: 7190276
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Error analysis of finite-spectral-linewidth illumination in optical oximetry systems.
    Hollmann JL; DiMarzio CA
    Adv Exp Med Biol; 2008; 614():209-15. PubMed ID: 18290331
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [Device for the determination of the degree of blood hemoglobin saturation with oxygen in an artificial circulation apparatus system].
    Kruzhalova IA; Malysheva VV; Nikonorova TK; Levin EA
    Nov Med Tekh; 1976; (3):41-4. PubMed ID: 1028976
    [No Abstract]   [Full Text] [Related]  

  • 29. Haemoglobin oxygenation of a two-layer tissue-simulating phantom from time-resolved reflectance: effect of top layer thickness.
    Hunter RJ; Patterson MS; Farrell TJ; Hayward JE
    Phys Med Biol; 2002 Jan; 47(2):193-208. PubMed ID: 11837612
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Plano-concave microcuvette for measuring the absorption coefficient of highly absorbing liquids.
    Csete M; Bor Z
    Appl Opt; 1997 Apr; 36(10):2133-8. PubMed ID: 18253183
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Toward absolute reflectance oximetry: I. Theoretical consideration for noninvasive tissue reflectance oximetry.
    Takatani S
    Adv Exp Med Biol; 1989; 248():91-102. PubMed ID: 2782194
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Variations in rat mesenteric tissue thickness due to microvasculature.
    Barber BJ; Oppenheimer J; Zawieja DC; Zimmermann HA
    Am J Physiol; 1987 Oct; 253(4 Pt 1):G549-56. PubMed ID: 3661712
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Pulse oximetry or pulse photometry.
    Anderson A
    Anaesth Intensive Care; 1991 Nov; 19(4):614. PubMed ID: 1750660
    [No Abstract]   [Full Text] [Related]  

  • 34. Validation of a high-power, time-resolved, near-infrared spectroscopy system for measurement of superficial and deep muscle deoxygenation during exercise.
    Koga S; Barstow TJ; Okushima D; Rossiter HB; Kondo N; Ohmae E; Poole DC
    J Appl Physiol (1985); 2015 Jun; 118(11):1435-42. PubMed ID: 25840439
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Measurement of indocyanine green dye with a cuvette oximeter.
    Sekelj P; Oriol A; Anderson NM; Morch J; McGregor M
    J Appl Physiol; 1967 Jul; 23(1):114-20. PubMed ID: 5339058
    [No Abstract]   [Full Text] [Related]  

  • 36. Hemoglobin determination with paired emitter detector diode.
    Mieczkowska E; Koncki R; Tymecki Ł
    Anal Bioanal Chem; 2011 Mar; 399(9):3293-7. PubMed ID: 21046074
    [TBL] [Abstract][Full Text] [Related]  

  • 37. In vitro oxyhaemoglobin saturation measurements in haemoglobin solutions using fibreoptic pulmonary artery catheters.
    Kong CS; Ryder IG; Kahn R; Gregory L; Mackenzie CF
    Br J Anaesth; 1995 Feb; 74(2):201-8. PubMed ID: 7696072
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Accuracy of Pulse Oximeters Intended for Hypoxemic Pediatric Patients.
    Harris BU; Char DS; Feinstein JA; Verma A; Shiboski SC; Ramamoorthy C
    Pediatr Crit Care Med; 2016 Apr; 17(4):315-20. PubMed ID: 26914626
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Two methods to adapt the human haemoglobin-oxygen dissociation algorithm to the blood of white rhinoceros (Ceratotherium simum) and to determine the accuracy of pulse oximetry.
    Haymerle A; Knauer F; Walzer C
    Vet Anaesth Analg; 2016 Sep; 43(5):566-70. PubMed ID: 26821767
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Does the estimation of light attenuation in tissue increase the accuracy of reflectance pulse oximetry at low oxygen saturations in vivo?
    Kisch-Wedel H; Bernreuter P; Kemming G; Albert M; Zwissler B
    IEEE Trans Biomed Eng; 2009 Sep; 56(9):2271-9. PubMed ID: 19692303
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.