These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
99 related articles for article (PubMed ID: 5650829)
1. Optimum duration of 60-HZ current for direct ventricular defibrillation in the dog. Gullett JR; Havens WW; Tacker WA; Geddes LA; Hoff HE Cardiovasc Res Cent Bull; 1968; 6(3):117-23. PubMed ID: 5650829 [No Abstract] [Full Text] [Related]
2. Minimum duration of capacitor discharge current for indirect ventricular defibrillation in the dog. Tacker WA; Havens WW; Geddes LA Cardiovasc Res Cent Bull; 1968; 7(1):21-6. PubMed ID: 5743486 [No Abstract] [Full Text] [Related]
3. Influence of acute coronary artery occlusion on direct ventricular defibrillation in dogs. Ruffy R; Schwartz DJ; Hieb BR Med Instrum; 1980; 14(1):23-6. PubMed ID: 7354732 [TBL] [Abstract][Full Text] [Related]
4. [The role of the intensity, duration and energy of the electrical impulse in cardiac defibrillation]. Makarychev VA Biull Eksp Biol Med; 1966 Jun; 61(6):27-30. PubMed ID: 6005269 [No Abstract] [Full Text] [Related]
5. Ventricular defibrillation in the dog with a bielectrode intravascular catheter. Schuder JC; Stoeckle H; West JA; Keskar PY; Gold JH; Denniston RH Arch Intern Med; 1973 Aug; 132(2):286-90. PubMed ID: 4719549 [No Abstract] [Full Text] [Related]
6. Direct comparison of monophasic, biphasic and sequential pulse defibrillation over a single current pathway. Thakur R; Souza JJ; Chapman PD; Troup PJ; Wetherbee JN Can J Cardiol; 1996 Apr; 12(4):407-11. PubMed ID: 8608460 [TBL] [Abstract][Full Text] [Related]
8. [Transthoracic defibrillation of cardiac ventricles: effects of novocainamide on effectiveness of an electric impulse of bipolar sinusoidal shape]. Vostrikov VA; Bogushevich MS; Mikhaĭlov IV Patol Fiziol Eksp Ter; 1999; (2):23-6. PubMed ID: 10379179 [TBL] [Abstract][Full Text] [Related]
9. [Transthoracic defibrillation of heart ventricles: effectiveness and safety of mono- and bipolar impulses]. Vostrikov VA; Bogushevich MS; Kholin PV Anesteziol Reanimatol; 1994; (5):9-11. PubMed ID: 7893086 [TBL] [Abstract][Full Text] [Related]
10. [Hilbert transform analysis of the relation between ventricular fibrillation voltage and the outcome of defibrillation shocks]. Wang K; Deng X; Guo R; Patwardhan A; Leonelli F Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2006 Jun; 23(3):512-6. PubMed ID: 16856380 [TBL] [Abstract][Full Text] [Related]
11. [Experimental evaluation of indirect defibrillation of the heart]. Arcimionek C; Bocian J; Serafin B Kardiol Pol; 1966; 9(3):203-7. PubMed ID: 5928292 [No Abstract] [Full Text] [Related]
12. Experimental ventricular defibrillation with an automatic and completely implanted system. Schuder JC; Stoeckle H; Gold JH; West JA; Keskar PY Trans Am Soc Artif Intern Organs; 1970; 16():207-12. PubMed ID: 5454169 [No Abstract] [Full Text] [Related]
13. Ventricular defibrillation with myocardial electrodes in the dog, calf, pony, and pig. Gold JH; Schuder JC; Stoeckle H Med Instrum; 1980; 14(1):19-22. PubMed ID: 7354731 [TBL] [Abstract][Full Text] [Related]
14. The influence of cycle frequency on the effectiveness of electrical defibrillation of the canine ventricles. Witzel D; Geddes LA; McFarlane J; Nichols W Cardiovasc Res Cent Bull; 1967; 5(4):112-8. PubMed ID: 6043740 [No Abstract] [Full Text] [Related]
15. Letter by Sullivan regarding article, "Hands-on defibrillation: an analysis of electrical current flow through rescuers in direct contact with patients during biphasic external defibrillation". Sullivan JL Circulation; 2008 Dec; 118(23):e712; author reply e713. PubMed ID: 19047587 [No Abstract] [Full Text] [Related]
16. Optimum current duration for capacitor-discharge defibrillation of canine ventricles. Tacker WA; Geddes LA; McFarlane J; Milnor W; Gullett J; Havens W; Green E; Moore J J Appl Physiol; 1969 Oct; 27(4):480-3. PubMed ID: 5822555 [No Abstract] [Full Text] [Related]
18. [The threshold of synchronous response of the myocardial fibers. Application to the experimental comparison of the efficacy of different forms of electroshock defibrillation]. Fabiato A; Coumel P; Gourgon R; Saumont R Arch Mal Coeur Vaiss; 1967 Apr; 60(4):527-44. PubMed ID: 4964651 [No Abstract] [Full Text] [Related]
19. [The shape of high-voltage impulse and the effect of defibrillation]. Moroz VV; Bogushevich MS; Vostrikov VA; Kozlova EK; Chernysh AM Anesteziol Reanimatol; 2002; (6):60-3. PubMed ID: 12611162 [TBL] [Abstract][Full Text] [Related]