These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

104 related articles for article (PubMed ID: 5651239)

  • 1. Safe standard of aeration for ethylene oxide sterilized supplies.
    Matsumoto T; Hardaway RM; Pani KC; Sater CM; Bartak DE; Margetis PM
    Arch Surg; 1968 Mar; 96(3):464-70. PubMed ID: 5651239
    [No Abstract]   [Full Text] [Related]  

  • 2. The determination of residual ethylene oxide and halogenated hydrocarbon propellants in sterilized plastics.
    Warren B
    J Pharm Pharmacol; 1971 Dec; 23():170S-175S. PubMed ID: 4401453
    [No Abstract]   [Full Text] [Related]  

  • 3. Determination of residual ethylene oxide in catheters by gas-liquid chromatography.
    Kulkarni RK; Bartak D; Ousterhout DK; Leonard F
    J Biomed Mater Res; 1968 Mar; 2(1):165-71. PubMed ID: 5708003
    [No Abstract]   [Full Text] [Related]  

  • 4. Determination of 2-chloroethanol in surgical materials by extraction and gas chromatography.
    Whitbourne JE; Mogenhan JA; Ernst RR
    J Pharm Sci; 1969 Aug; 58(8):1024-5. PubMed ID: 5344516
    [No Abstract]   [Full Text] [Related]  

  • 5. Infection control-central service: on the avoidance of failures in sterilization.
    Starkey DH; Himmelsbach CK
    Hospitals; 1974 Jul; 48(13):143-52. PubMed ID: 4600331
    [No Abstract]   [Full Text] [Related]  

  • 6. Determination of ethylene oxide in surgical materials by vacuum extraction and gas chromatography.
    Mogenhan JA; Whitbourne JE; Ernst RR
    J Pharm Sci; 1971 Feb; 60(2):222-4. PubMed ID: 5572443
    [No Abstract]   [Full Text] [Related]  

  • 7. Basics of packaging.
    Ryan P
    AORN J; 1975 May; 21(6):1091-2 passim. PubMed ID: 1038973
    [No Abstract]   [Full Text] [Related]  

  • 8. Comparative chemical and toxicological evaluation of residual ethylene oxide in sterilized plastics.
    O'Leary RK; Watkins WD; Guess WL
    J Pharm Sci; 1969 Aug; 58(8):1007-10. PubMed ID: 5344512
    [No Abstract]   [Full Text] [Related]  

  • 9. Ethylene oxide residues in sterilized medical devices.
    Charlesworth FA
    Food Cosmet Toxicol; 1976 Jan; 14(1):61. PubMed ID: 1254209
    [No Abstract]   [Full Text] [Related]  

  • 10. [Ethylene oxide residues and aeration time after use of modern heated aerators (author's transl)].
    Star EG
    Zentralbl Bakteriol Mikrobiol Hyg B; 1980 Jun; 171(1):18-24. PubMed ID: 7434997
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Toxicological studies on certain medical grade plastics sterilized by ethylene oxide.
    O'Leary RK; Guess WL
    J Pharm Sci; 1968 Jan; 57(1):12-7. PubMed ID: 5652113
    [No Abstract]   [Full Text] [Related]  

  • 12. Haemolysis of blood following exposure to an Australian manufactured plastic tubing sterilized by means of ethylene-oxide gas.
    Clarke CP; Davidson WL; Johnston JB
    Aust N Z J Surg; 1966 Aug; 36(1):53-6. PubMed ID: 5225580
    [No Abstract]   [Full Text] [Related]  

  • 13. Rapid gas chromatographic determination of ethylene oxide, ethylene chlorohydrin, and ethylene glycol residues in rubber catheters.
    Muzeni RJ
    J Assoc Off Anal Chem; 1985; 68(3):506-8. PubMed ID: 4019375
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Ethylene oxide toxicity. A study of tissue reactions to retained ethylene oxide.
    Andersen SR
    J Lab Clin Med; 1971 Feb; 77(2):346-56. PubMed ID: 5540778
    [No Abstract]   [Full Text] [Related]  

  • 15. Ethylene oxide degassing of rubber and plastic materials.
    Stetson JB; Whitbourne JE; Eastman C
    Anesthesiology; 1976 Feb; 44(2):174-80. PubMed ID: 1252029
    [No Abstract]   [Full Text] [Related]  

  • 16. EO: despite call for FDA action, research goes on.
    Porter KW
    Hospitals; 1973 Aug; 47(15):117-9. PubMed ID: 4740467
    [No Abstract]   [Full Text] [Related]  

  • 17. Standard aeration for gas-sterilized plastics.
    White JD
    J Hyg (Lond); 1977 Oct; 79(2):225-32. PubMed ID: 269198
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Microwave desorption: a combined sterilizer/aerator for the accelerated elimination of ethylene oxide residues from sterilized supplies.
    Samuel AH; Matthews IP; Gibson C
    Med Instrum; 1988 Feb; 22(1):39-44. PubMed ID: 3357464
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [The practice of ethylene oxide sterilization].
    Binder H; Möse JR; Tscheliessnigg K
    Zentralbl Bakteriol Mikrobiol Hyg B; 1982; 176(5-6):453-62. PubMed ID: 6961707
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Absorption and desorption of ethylene-oxide in anaesthesia-supplies (author's transl)].
    Star EG
    Zentralbl Bakteriol B Hyg Krankenhaushyg Betriebshyg Prav Med; 1980; 170(5-6):557-69. PubMed ID: 7424291
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.