These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
102 related articles for article (PubMed ID: 567324)
1. In vivo measurement of carbon dioxide tension with a miniature electrode. Olievier CN; Berkenbosch A; Quanjer PH Pflugers Arch; 1978 Mar; 373(3):269-72. PubMed ID: 567324 [TBL] [Abstract][Full Text] [Related]
2. Development of an instrument to indirectly monitor arterial pCO2 during cardiopulmonary bypass. Høgetveit JO; Kristiansen F; Pedersen TH Perfusion; 2006 Jan; 21(1):13-9. PubMed ID: 16485694 [TBL] [Abstract][Full Text] [Related]
3. Simplified dual-lumen catheter design for simultaneous potentiometric monitoring of carbon dioxide and pH. Telting-Diaz M; Collison ME; Meyerhoff ME Anal Chem; 1994 Feb; 66(4):576-83. PubMed ID: 8154586 [TBL] [Abstract][Full Text] [Related]
4. Problems with the gas-calibrated PCO2 electrode. Bateman NT; Musch TI; Smith CA; Dempsey JA Respir Physiol; 1980 Aug; 41(2):217-26. PubMed ID: 6776600 [TBL] [Abstract][Full Text] [Related]
5. Continuous intravascular monitoring of pO2 and pCO2. A comparative in vitro-in vivo study. Huchon G; Blayo MC; Vallois JM; Chirico A; Morizet P; Caudebourt C Eur J Intensive Care Med; 1976; 2(1):23-8. PubMed ID: 954761 [TBL] [Abstract][Full Text] [Related]
6. Transcutaneous carbon dioxide and oxygen tension measured at different temperatures in healthy adults. Wimberley PD; Grønlund Pedersen K; Olsson J; Siggaard-Andersen O Clin Chem; 1985 Oct; 31(10):1611-5. PubMed ID: 3930089 [TBL] [Abstract][Full Text] [Related]
7. Measurement of blood CO2 concentration with a conventional PCO2 analyzer. Breen PH; Mazumdar B; Skinner SC; Taitelman UZ; Isserles SA Crit Care Med; 1996 Jul; 24(7):1215-8. PubMed ID: 8674338 [TBL] [Abstract][Full Text] [Related]
8. Clinical evaluation of an instrument to measure carbon dioxide tension at the oxygenator gas outlet in cardiopulmonary bypass. Kristiansen F; Høgetveit JO; Pedersen TH Perfusion; 2006 Jan; 21(1):21-6. PubMed ID: 16485695 [TBL] [Abstract][Full Text] [Related]
9. tcPCO2 electrode design, calibration and temperature gradient problems. Severinghaus JW; Stafford M; Bradley AF Acta Anaesthesiol Scand Suppl; 1978; 68():118-22. PubMed ID: 29431 [TBL] [Abstract][Full Text] [Related]
10. Evaluation of a dual-function pH and PCO2 in vivo sensor. Coon RL; Lai NC; Kampine JP J Appl Physiol; 1976 Apr; 40(4):625-9. PubMed ID: 6422 [TBL] [Abstract][Full Text] [Related]
11. Transcutaneous and capillary pCO2 and pO2 measurements in healthy adults. Wimberley PD; Pedersen KG; Thode J; Fogh-Andersen N; Sørensen AM; Siggaard-Andersen O Clin Chem; 1983 Aug; 29(8):1471-3. PubMed ID: 6409449 [TBL] [Abstract][Full Text] [Related]
12. Catheter-type sensor for potentiometric monitoring of oxygen, pH and carbon dioxide. Meruva RK; Meyerhoff ME Biosens Bioelectron; 1998 Feb; 13(2):201-12. PubMed ID: 9597736 [TBL] [Abstract][Full Text] [Related]
13. Estimation of PaCO2 by two noninvasive methods in the critically ill newborn infant. Epstein MF; Cohen AR; Feldman HA; Raemer DB J Pediatr; 1985 Feb; 106(2):282-6. PubMed ID: 3918157 [TBL] [Abstract][Full Text] [Related]
14. Calibration of a heated transcutaneous carbon dioxide electrode to reflect arterial carbon dioxide. Monaco F; McQuitty JC; Nickerson BG Am Rev Respir Dis; 1983 Mar; 127(3):322-4. PubMed ID: 6402964 [TBL] [Abstract][Full Text] [Related]