These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

119 related articles for article (PubMed ID: 5683415)

  • 1. Fatal degeneration of the silicone rubber ball of the Starr-Edwards prosthetic aortic valve.
    Roberts WC; Morrow AG
    Am J Cardiol; 1968 Nov; 22(5):614-20. PubMed ID: 5683415
    [No Abstract]   [Full Text] [Related]  

  • 2. [Late results following aortic valve replacement. Report on 150 cases of prosthetic valve surgery using the Starr-Edwards prosthesis].
    Stapenhorst K; Brunner L; Hoffmeister HE; Kirchhoff PG; Rastan H; Koncz J
    Thoraxchir Vask Chir; 1971 Aug; 19(4):298-304. PubMed ID: 4998709
    [No Abstract]   [Full Text] [Related]  

  • 3. [Case of acute hemolytic anemia caused by "cloth wear" following aortic valve replacement by Starr-Edwards ball valve Model 2400, 9A].
    Maeda S; Miyamoto T; Shimizu Y; Ozawa M; Ohashi H; Oka Y; Tomita E; Yamashita K; Ogawa N
    Nihon Kyobu Geka Gakkai Zasshi; 1982 Jul; 30(7):1285-90. PubMed ID: 7175269
    [No Abstract]   [Full Text] [Related]  

  • 4. An unusual lethal complication associated with Starr-Edwards prosthetic aortic valve holder.
    Nandi P; Tse TF; Ho FC; Leung JS
    Chest; 1977 Dec; 72(6):787-9. PubMed ID: 923319
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Late re-operation for aortic and mitral Starr-Edwards ball valve prostheses.
    Aoyagi S; Fukunaga S; Arinaga K; Yokokura Y; Yokokura H; Egawa N
    Asian Cardiovasc Thorac Ann; 2006 Dec; 14(6):467-71. PubMed ID: 17130320
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Infection within a degenerated Starr-Edwards silicone rubber poppet in the aortic valve position.
    Muller WA; Cohn LH; Schoen FJ
    Am J Cardiol; 1984 Nov; 54(8):1146. PubMed ID: 6496341
    [No Abstract]   [Full Text] [Related]  

  • 7. Fatal dislodgment of ball from aortic Starr--Edwards valve prosthesis.
    Düren DR; Becker AE; Wellens HJ
    Eur J Cardiol; 1975 Aug; 3(2):129-12. PubMed ID: 1183464
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Silicone ball variance. A clinical and pulse duplicator study.
    Collins JJ; Berg EJ; Harken DE
    Ann Thorac Surg; 1968 Dec; 6(6):546-51. PubMed ID: 5745865
    [No Abstract]   [Full Text] [Related]  

  • 9. Late ball variance with the Model 1000 Starr-Edwards aortic valve prosthesis. Risk analysis and strategy of operative management.
    Grunkemeier GL; Starr A
    J Thorac Cardiovasc Surg; 1986 Jun; 91(6):918-23. PubMed ID: 3713241
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Twenty-four years' implant duration of the aortic Starr-Edwards Silastic ball prosthesis: a valve of the past?
    Mächler HE; Schmidt CH; Neuner P; Iberer F; Anelli-Monti M; Dacar D; Rigler B; Kraft-Kinz J
    Eur J Cardiothorac Surg; 1993; 7(3):114-6. PubMed ID: 8384861
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fatal obstruction of the aortic root by Starr-Edwards aortic ball-valve prosthesis.
    Najafi H; DeWall RA
    J Thorac Cardiovasc Surg; 1966 Feb; 51(2):180-4. PubMed ID: 5903627
    [No Abstract]   [Full Text] [Related]  

  • 12. Hematogenous dissemination of microemboli. Eye findings in a patient with Starr-Edwards aortic prosthesis.
    Ide CH; Almond CH; Hart WM; Simmons EM; Wilson RJ
    Arch Ophthalmol; 1971 May; 85(5):614-7. PubMed ID: 5087602
    [No Abstract]   [Full Text] [Related]  

  • 13. Ball variance: potentially lethal degeneration of the Starr-Edwards aortic valve poppet.
    Crews TL; Frank MJ; Ellison RG; Teabeaut JR; Harper HT
    J Med Assoc Ga; 1970 Apr; 59(4):135-9. PubMed ID: 5427596
    [No Abstract]   [Full Text] [Related]  

  • 14. Double prosthetic aortic valve. Late aortic erosion by Hufnagel valve.
    Popma BH; Goldstein AS; Jacques J; Guenter CA
    Chest; 1976 Nov; 70(5):660-2. PubMed ID: 975986
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Chronic hemolysis following aortic valve replacement: comparison of Starr-Edwards ball valve and Björk-Shiley valve].
    Oka Y; Miyamoto T; Shimizu Y; Iioka S; Ohashi H; Tomita E; Maeda S; Ogawa N; Yoshida T
    Nihon Kyobu Geka Gakkai Zasshi; 1983 Jul; 31(7):1041-8. PubMed ID: 6631134
    [No Abstract]   [Full Text] [Related]  

  • 16. Intravascular haemolysis after valve replacement: comparative study between Starr-Edwards (ball valve) and Björk-Shiley (disc valve) prosthesis.
    Falk RH; Mackinnon J; Wainscoat J; Melikian V; Bignell AH
    Thorax; 1979 Dec; 34(6):746-8. PubMed ID: 542913
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Current status of the Beall, Bjork-Shiley, Braunwald-Cutter, Lillehei-Kaster and Smeloff-Cutter cardiac valve prostheses.
    Brawley RK; Donahoo JS; Gott VL
    Am J Cardiol; 1975 Jun; 35(6):855-65. PubMed ID: 124127
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [A study on anticoagulations and thromboembolic complication in aortic and double valve replacement with Starr-Edwards ball valve prostheses (author's transl)].
    Sakashita I; Nakamura C; Ohtani S; Asano K
    Nihon Kyobu Geka Gakkai Zasshi; 1977 Nov; 25(11):1470-5. PubMed ID: 609012
    [No Abstract]   [Full Text] [Related]  

  • 19. Hemolysis in the aortic prosthetic valve.
    Santinga JT; Batsakis JT; Flora JD; Kirsh MM
    Chest; 1976 Jan; 69(1):56-61. PubMed ID: 1244290
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Mechanical failure of Starr-Edwards aortic prosthesis due to ball fracture.
    Newman MM; Hoffman MS; Gesink MH
    J Thorac Cardiovasc Surg; 1967 Mar; 53(3):398-400. PubMed ID: 6019152
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 6.