These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
23. Right Ventricular Perforation Caused by a Pacing Catheter Two Weeks After Insertion in a Neonate With Congenital Atrioventricular Block. Ota N; Suzuki R; Latiff HA; Sivalingam S Ann Thorac Surg; 2015 Oct; 100(4):1471. PubMed ID: 26434454 [No Abstract] [Full Text] [Related]
24. Value of the unipolar electrogram in the diagnosis of right ventricular perforation following pacemaker implantation. Macdonald J; Kelly D; Waktare J Heart; 2005 Feb; 91(2):228. PubMed ID: 15657243 [No Abstract] [Full Text] [Related]
25. Fatal outcome arising from use of a sutureless "corkscrew" epicardial pacing electrode inserted into apex of left ventricle. Vecht RJ; Fontaine CJ; Bradfield JW Br Heart J; 1976 Dec; 38(12):1359-62. PubMed ID: 1008980 [TBL] [Abstract][Full Text] [Related]
26. Myocardial perforation from a permanent endocardial electrode. Meckstroth CV; Schoenfeld CD; Wardwell GA J Thorac Cardiovasc Surg; 1967 Jul; 54(1):16-21. PubMed ID: 6027854 [No Abstract] [Full Text] [Related]
27. Perforation of the right ventricle by pacing catheter electrode. Two cases of asymptomatic perforation with survival. Fort ML; Sharp JT Am J Cardiol; 1965 Oct; 16(4):610-3. PubMed ID: 5834484 [No Abstract] [Full Text] [Related]
28. Perforation of myocardium by pacemaker catheter. Alegre JM; Yore R JAMA; 1970 Apr; 212(3):481. PubMed ID: 5467304 [No Abstract] [Full Text] [Related]
29. Delayed right ventricular perforation with a pacemaker lead into subcutaneous tissues. Amara W; Cymbalista M; Sergent J Arch Cardiovasc Dis; 2010 Jan; 103(1):53-4. PubMed ID: 20142121 [No Abstract] [Full Text] [Related]
30. Echocardiographic detection of perforation of the cardiac ventricular septum by a permanent pacemaker lead. Villanueva FS; Heinsimer JA; Burkman MH; Fananapazir L; Halvorsen RA; Chen JT Am J Cardiol; 1987 Feb; 59(4):370-1. PubMed ID: 3812294 [No Abstract] [Full Text] [Related]
31. Live three-dimensional echocardiography in diagnosis of interventricular septal perforation by pacemaker lead. Daher IN; Saeed M; Schwarz ER; Agoston I; Rahman MA; Ahmad M Echocardiography; 2006 May; 23(5):428-9. PubMed ID: 16686631 [No Abstract] [Full Text] [Related]
32. Old is gold: tip electrograms to diagnose pacemaker lead perforation. Chandan K; Ponde C; Lokhandwala Y; Nandkumar K J Cardiovasc Electrophysiol; 2002 Oct; 13(10):1063. PubMed ID: 12435201 [No Abstract] [Full Text] [Related]
33. Unusual qrs complexes produced by pacemaker stimuli with special reference to myocardial tunneling and coronary sinus stimulation. Castellanos A; Maytin O; Lemberg L; Castillo C Am Heart J; 1969 Jun; 77(6):732-42. PubMed ID: 5770147 [No Abstract] [Full Text] [Related]
34. The significance of intraventricular electrocardiogram in artificial heart pacing. Observations made on 232 patients. Gialafos J; Kolettis M; Hadijgeorge C; Georgiou V; Avgoustakis D Acta Cardiol; 1975; 30(6):487-97. PubMed ID: 132833 [TBL] [Abstract][Full Text] [Related]
35. Delayed perforation of the right ventricle as a complication of permanent cardiac pacing - is following the guidelines always the right choice? Non-standard treatment - a case report and literature review. Rydlewska A; Małecka B; Zabek A; Klimeczek P; Lelakowski J; Pasowicz M; Czajkowski M; Kutarski A Kardiol Pol; 2010 Mar; 68(3):357-61. PubMed ID: 20411465 [TBL] [Abstract][Full Text] [Related]
36. Uneventful right ventricular perforation with displacement of a pacing lead into the left thorax. Boriani G; Biffi M; Martignani C J Cardiothorac Vasc Anesth; 2008 Jun; 22(3):423-5. PubMed ID: 18503932 [No Abstract] [Full Text] [Related]
37. The bite of the lead: multiorgan perforation by an active-fixation permanent pacemaker lead. Madershahian N; Wippermann J; Wahlers T Interact Cardiovasc Thorac Surg; 2010 Jul; 11(1):93-4. PubMed ID: 20388699 [TBL] [Abstract][Full Text] [Related]
38. Perforations of right heart chambers associated with electrophysiology catheters and temporary transvenous pacing leads. Aliyev F; Celiker C; Türkoğlu C; Karadağ B; Yıldız A Turk Kardiyol Dern Ars; 2011 Jan; 39(1):16-22. PubMed ID: 21358226 [TBL] [Abstract][Full Text] [Related]
39. CT demonstration of myocardial perforation by a pacemaker lead. Sussman SK; Chiles C; Cooper C; Lowe JE J Comput Assist Tomogr; 1986; 10(4):670-2. PubMed ID: 3734207 [TBL] [Abstract][Full Text] [Related]
40. [Letter: The origin of the pacemaker sound]. Alhomme P Nouv Presse Med; 1973 Oct; 2(37):2477. PubMed ID: 4748650 [No Abstract] [Full Text] [Related] [Previous] [Next] [New Search]