These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
5. [Hemodynamic performance of newly developed composite stentless porcine aortic valve: in vitro testing and in vivo experiment with sheep]. Song GM; Zhou JY; Hu SS; Cui JW; Song YH; Tang Y; Zhang Y; Jiang H; Yuan WM; Song XY Zhonghua Yi Xue Za Zhi; 2008 Jul; 88(29):2059-63. PubMed ID: 19080436 [TBL] [Abstract][Full Text] [Related]
6. In vitro pulsatile flow evaluation of a stentless porcine aortic bioprosthesis. Sung HW; Le TN; Kingsbury CJ; Quintero LJ; Myers KE; Quijano RC ASAIO J; 1995; 41(1):89-94. PubMed ID: 7727828 [TBL] [Abstract][Full Text] [Related]
7. [Hemodynamic evaluation of the Carpentier-Edwards porcine bioprosthesis and the Hancock pericardial bioprosthesis in aortic position]. Cohen-Solal A; Leroy G; Hittinger L; Fernandez F; Gay J; Gourgon R Arch Mal Coeur Vaiss; 1986 Mar; 79(3):346-54. PubMed ID: 3087318 [TBL] [Abstract][Full Text] [Related]
8. Cyclic loading response of bioprosthetic heart valves: effects of fixation stress state on the collagen fiber architecture. Wells SM; Sellaro T; Sacks MS Biomaterials; 2005 May; 26(15):2611-9. PubMed ID: 15585264 [TBL] [Abstract][Full Text] [Related]
9. Effects of fixation back pressure and antimineralization treatment on the morphology of porcine aortic bioprosthetic valves. Flomenbaum MA; Schoen FJ J Thorac Cardiovasc Surg; 1993 Jan; 105(1):154-64. PubMed ID: 8419696 [TBL] [Abstract][Full Text] [Related]
10. In vitro hydrodynamic comparison of mitral valve prostheses at high flow rates. Gabbay S; McQueen DM; Yellin EL; Becker RM; Frater RW J Thorac Cardiovasc Surg; 1978 Dec; 76(6):771-87. PubMed ID: 713584 [TBL] [Abstract][Full Text] [Related]
11. Experimental studies of the anatomical and functional characteristics of kangaroo aortic valve bioprostheses. Weinhold C; Reichart B; Kemkes BM; Schaff J; Davila J; Eberhard C Life Support Syst; 1984; 2(2):121-5. PubMed ID: 6482505 [TBL] [Abstract][Full Text] [Related]
12. Hemodynamic function of the Hancock standard orifice aortic valve bioprosthesis. Borkon AM; McIntosh CL; Jones M; Lipson LC; Kent KM; Morrow AG J Thorac Cardiovasc Surg; 1981 Oct; 82(4):601-7. PubMed ID: 7278353 [TBL] [Abstract][Full Text] [Related]
13. In vitro function and durability of a polyurethane heart valve: material considerations. Bernacca GM; Mackay TG; Wheatley DJ J Heart Valve Dis; 1996 Sep; 5(5):538-42. PubMed ID: 8894995 [TBL] [Abstract][Full Text] [Related]
14. Morphologic findings in explanted Hancock II porcine bioprostheses. Butany J; Yu W; Silver MD; David TE J Heart Valve Dis; 1999 Jan; 8(1):4-15. PubMed ID: 10096476 [TBL] [Abstract][Full Text] [Related]
15. Durability of prosthetic heart valves. Clark RE; Swanson WM; Kardos JL; Hagen RW; Beauchamp RA Ann Thorac Surg; 1978 Oct; 26(4):323-35. PubMed ID: 753145 [TBL] [Abstract][Full Text] [Related]
16. A novel pulse duplicator system: evaluation of different valve prostheses. Haaf P; Steiner M; Attmann T; Pfister G; Cremer J; Lutter G Thorac Cardiovasc Surg; 2009 Feb; 57(1):10-7. PubMed ID: 19169990 [TBL] [Abstract][Full Text] [Related]
17. [Structural changes of Hancock bioprostheses in children (author's transl)]. Bortolotti U; Milano A; Mazzucco A; Callucci V; Valente M; Del Maschio A; Valfrè C; Thiene G G Ital Cardiol; 1980; 10(11):1520-5. PubMed ID: 7202899 [TBL] [Abstract][Full Text] [Related]
18. Porcine valves: Hancock and Carpentier-Edwards aortic prostheses. Fann JI; Miller DC Semin Thorac Cardiovasc Surg; 1996 Jul; 8(3):259-68. PubMed ID: 8843517 [TBL] [Abstract][Full Text] [Related]