These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

145 related articles for article (PubMed ID: 5732233)

  • 1. [The method of determination of oxygen tension by solid golden spherical electrode].
    Karpinskaia NL; Naumenko AI
    Fiziol Zh SSSR Im I M Sechenova; 1968 Aug; 54(8):981-5. PubMed ID: 5732233
    [No Abstract]   [Full Text] [Related]  

  • 2. [Application of the theory of spheric diffusion in determination of oxygen tension on the solid gold spherical electrode].
    Karpinskii NL; Naumenko AI; Karninskiĭ RA
    Fiziol Zh SSSR Im I M Sechenova; 1969 Sep; 55(9):1125-31. PubMed ID: 5357492
    [No Abstract]   [Full Text] [Related]  

  • 3. [Statistical characteristics of slow fluctuations of the blood flow and oxygen tension in the brain].
    Fedulova IP
    Fiziol Zh SSSR Im I M Sechenova; 1971 Apr; 57(4):584-90. PubMed ID: 4997855
    [No Abstract]   [Full Text] [Related]  

  • 4. Brain tissue reoxygenation time, demonstrated with a new ultramicro oxygen electrode.
    Bicher HI; Knisely MH
    J Appl Physiol; 1970 Mar; 28(3):387-90. PubMed ID: 5414779
    [No Abstract]   [Full Text] [Related]  

  • 5. [Automatic stabilization of the oxygen tension in gas mixtures using a rapid polarographic oxygen electrode].
    Schuler R; Ackermann H
    Helv Physiol Pharmacol Acta; 1967; 25(4):CR435+. PubMed ID: 5586889
    [No Abstract]   [Full Text] [Related]  

  • 6. Measurement of circulating alcohol with a tcPO2 electrode.
    Clark LC
    Birth Defects Orig Artic Ser; 1979; 15(4):37-8. PubMed ID: 534718
    [No Abstract]   [Full Text] [Related]  

  • 7. [Transcutaneous determination of oxygen tension--methodological, physiological and clinical aspects].
    Kobuliia BG; Tskhovrebashvili NG
    Ter Arkh; 1984; 56(4):147-51. PubMed ID: 6374956
    [No Abstract]   [Full Text] [Related]  

  • 8. [Device for the simultaneous registration of oxygen tension and retinal biopotentials in chronic experiments].
    Volkova AD; Iakovlev AA
    Vestn Oftalmol; 1973; 2():49-51. PubMed ID: 4754081
    [No Abstract]   [Full Text] [Related]  

  • 9. A digital polarograph for the evaluation of membrane PO2 electrodes.
    Fesler R; Clerbaux T
    Med Lab Technol; 1971 Oct; 28(4):394-6. PubMed ID: 5116326
    [No Abstract]   [Full Text] [Related]  

  • 10. [An electrode for continuous measurement of oxygen tension in fermenter cultures].
    Ring K; Schlecht S; Eschweiler W; Kutscher J
    Arch Mikrobiol; 1969; 65(1):48-60. PubMed ID: 4915430
    [No Abstract]   [Full Text] [Related]  

  • 11. Modification of electrochemical determination of oxygen tension in organs.
    Zima M
    Sb Ved Pr Lek Fak Karlovy Univerzity Hradci Kralove; 1980; 23(4):557-65. PubMed ID: 6970977
    [No Abstract]   [Full Text] [Related]  

  • 12. [Effect of prostaglandin F2 alpha on the cerebral circulation in cats].
    Nikolov R
    Eksp Med Morfol; 1980; 19(1):16-20. PubMed ID: 7389641
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Method for the multichannel polarography of the oxygen in biological objects].
    Enokian SG
    Fiziol Zh (1978); 1980; 26(5):703-5. PubMed ID: 7428976
    [No Abstract]   [Full Text] [Related]  

  • 14. Properties of a combined sensor for dynamic measurement of oxygen in simulated respiration.
    Küchler G; Wagner W; Wolburg I
    Biotelem Patient Monit; 1980; 7(2):122-30. PubMed ID: 6774787
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Tissue-pO 2 in carotid glomus of the cat].
    Acker H; Keller HP; Lübbers DW
    Arzneimittelforschung; 1972 Sep; 22(9):1557. PubMed ID: 4678621
    [No Abstract]   [Full Text] [Related]  

  • 16. Pulse polarography and intravascular oxygen electrodes.
    Scott IL; Black AM; Maynard P; Hahn CE
    Br J Anaesth; 1983 Jun; 55(6):559-67. PubMed ID: 6860525
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [A means of analyzing the results of chronoamperometric determination of oxygen on open indicator electrodes].
    Berezovskiĭ VA
    Fiziol Zh SSSR Im I M Sechenova; 1970 Aug; 56(8):1182-5. PubMed ID: 5508216
    [No Abstract]   [Full Text] [Related]  

  • 18. [Calibration of a polarographic electrode with different gas samples as an error factor in the measurement of partial pressure of blood oxygen].
    Terra Filho J; Manço JC; Gallo Júnior L; Marin Neto JA; Amorim Dde S
    Arq Bras Cardiol; 1980 May; 34(5):367-71. PubMed ID: 7458711
    [No Abstract]   [Full Text] [Related]  

  • 19. [Polarographic determination of oxygen in blood using 2 types of electrodes].
    Roehr EE
    Medicina (B Aires); 1969; 29(2):110-8. PubMed ID: 5795130
    [No Abstract]   [Full Text] [Related]  

  • 20. [Polarographic measurement of oxygen pressure in blood and tissues].
    Lamy M; Hanquet M
    Acta Anaesthesiol Belg; 1970; 21(2):141-63. PubMed ID: 5527110
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 8.